Christie MicroTiles 0.75 S60 · 0.75 mm

This sheet gives the datasheet figures for the Christie MicroTiles 0.75 S60, a 0.75 mm LED panel in a 240 × 270 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerChristie, MicroTiles LED series
Pixel pitch0.75 mm
Cabinet size240 × 270 × 85 mm
Pixels per cabinet320 × 360 (115,200 px)
Weight2.2 kg (34 kg/m²)
Max power, full white32 W (494 W/m²)
Typical power16 W
Refresh rate3,840 Hz
Brightness2,000 nits
Viewing angle (H / V)160° / 160°
Optical figuresbrightness calibrated; refresh given as up to 3,840 Hz
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly20 (our packing assumption)

Source: Christie: MicroTiles LED 0.75 mm data sheet, retrieved 2026-09-17. Fixed-install tile in the 8:9 MicroTiles format, fed at 48 V from a remote power supply or by Power over Ethernet, all service from the front, IP30, 34 kg/m² (49.4 kg/m² installed with the QuickMount). Sheet gives 16 W typical and 32 W maximum per tile; heat 55 and 109 BTU/h. The house circuits feed the remote supply rack, not the tiles. No hanging limit published, so the hang figure is a conservative placeholder.

Worked example: a 34 × 17 wall (16:9)

34 columns by 17 rows of this tile makes a 8.16 × 4.59 m wall, the closest this cabinet gets to 16:9, at 10,880 × 6,120 pixels (66.59 MP): 578 panels plus 29 spares at the one-off rate. It weighs about 1,272 kg, carried by the structure it is mounted on.

On European power it draws 18.5 kW at full white (9.2 kW on typical content), which at an 80% derate is 7 × 16 A / 230 V circuits. Data comes to 170 runs at up to 4 panels per port, worst run 71% loaded, fitting 34 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

wall-mounted: the structure carries 1,272 kg8.16 m (10,880 px)4.59 m (6,120 px)18.5 kW max · 7× 16 A / 230 V · 170 runs on 34× NovaStar VX1000

Main: 34 × 17 Christie MicroTiles 0.75 S60

Size
8.16 × 4.59 m
Diagonal
369 in
Area
37.5 m²
Resolution
10,880 × 6,120 px
Pixels
66.59 M px
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
18.5 kW max, 9.2 kW typical, 7 circuits
Data
170 runs on 34 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainChristie MicroTiles 0.75 S6034 × 178.16 × 4.59 m · 369 in10,880 × 6,120 pxwall-mounted
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
18.5 kW max, 9.2 kW typical, 7 circuits
Data
170 runs on 34 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Too big for one NovaStar VX1000 canvas: 10,880 px wide against a published maximum of 10,240. Split the wall across processors.

Data wiring 170 runs · up to 4 panels per run at 80% · worst 71% · 34× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 44 panels · 71% of port
Run 2Column 1, rows 5 to 84 panels · 71% of port
Run 3Column 1, rows 9 to 113 panels · 53% of port
Run 4Column 1, rows 12 to 143 panels · 53% of port
Run 5Column 1, rows 15 to 173 panels · 53% of port
Run 6Column 2, rows 1 to 44 panels · 71% of port
Run 7Column 2, rows 5 to 84 panels · 71% of port
Run 8Column 2, rows 9 to 113 panels · 53% of port
Run 9Column 2, rows 12 to 143 panels · 53% of port
Run 10Column 2, rows 15 to 173 panels · 53% of port
Run 11Column 3, rows 1 to 44 panels · 71% of port
Run 12Column 3, rows 5 to 84 panels · 71% of port
Run 13Column 3, rows 9 to 113 panels · 53% of port
Run 14Column 3, rows 12 to 143 panels · 53% of port
Run 15Column 3, rows 15 to 173 panels · 53% of port
Run 16Column 4, rows 1 to 44 panels · 71% of port
Run 17Column 4, rows 5 to 84 panels · 71% of port
Run 18Column 4, rows 9 to 113 panels · 53% of port
Run 19Column 4, rows 12 to 143 panels · 53% of port
Run 20Column 4, rows 15 to 173 panels · 53% of port
Run 21Column 5, rows 1 to 44 panels · 71% of port
Run 22Column 5, rows 5 to 84 panels · 71% of port
Run 23Column 5, rows 9 to 113 panels · 53% of port
Run 24Column 5, rows 12 to 143 panels · 53% of port
Run 25Column 5, rows 15 to 173 panels · 53% of port
Run 26Column 6, rows 1 to 44 panels · 71% of port
Run 27Column 6, rows 5 to 84 panels · 71% of port
Run 28Column 6, rows 9 to 113 panels · 53% of port
Run 29Column 6, rows 12 to 143 panels · 53% of port
Run 30Column 6, rows 15 to 173 panels · 53% of port
Run 31Column 7, rows 1 to 44 panels · 71% of port
Run 32Column 7, rows 5 to 84 panels · 71% of port
Run 33Column 7, rows 9 to 113 panels · 53% of port
Run 34Column 7, rows 12 to 143 panels · 53% of port
Run 35Column 7, rows 15 to 173 panels · 53% of port
Run 36Column 8, rows 1 to 44 panels · 71% of port
Run 37Column 8, rows 5 to 84 panels · 71% of port
Run 38Column 8, rows 9 to 113 panels · 53% of port
Run 39Column 8, rows 12 to 143 panels · 53% of port
Run 40Column 8, rows 15 to 173 panels · 53% of port
Run 41Column 9, rows 1 to 44 panels · 71% of port
Run 42Column 9, rows 5 to 84 panels · 71% of port
Run 43Column 9, rows 9 to 113 panels · 53% of port
Run 44Column 9, rows 12 to 143 panels · 53% of port
Run 45Column 9, rows 15 to 173 panels · 53% of port
Run 46Column 10, rows 1 to 44 panels · 71% of port
Run 47Column 10, rows 5 to 84 panels · 71% of port
Run 48Column 10, rows 9 to 113 panels · 53% of port
Run 49Column 10, rows 12 to 143 panels · 53% of port
Run 50Column 10, rows 15 to 173 panels · 53% of port
Run 51Column 11, rows 1 to 44 panels · 71% of port
Run 52Column 11, rows 5 to 84 panels · 71% of port
Run 53Column 11, rows 9 to 113 panels · 53% of port
Run 54Column 11, rows 12 to 143 panels · 53% of port
Run 55Column 11, rows 15 to 173 panels · 53% of port
Run 56Column 12, rows 1 to 44 panels · 71% of port
Run 57Column 12, rows 5 to 84 panels · 71% of port
Run 58Column 12, rows 9 to 113 panels · 53% of port
Run 59Column 12, rows 12 to 143 panels · 53% of port
Run 60Column 12, rows 15 to 173 panels · 53% of port
Run 61Column 13, rows 1 to 44 panels · 71% of port
Run 62Column 13, rows 5 to 84 panels · 71% of port
Run 63Column 13, rows 9 to 113 panels · 53% of port
Run 64Column 13, rows 12 to 143 panels · 53% of port
Run 65Column 13, rows 15 to 173 panels · 53% of port
Run 66Column 14, rows 1 to 44 panels · 71% of port
Run 67Column 14, rows 5 to 84 panels · 71% of port
Run 68Column 14, rows 9 to 113 panels · 53% of port
Run 69Column 14, rows 12 to 143 panels · 53% of port
Run 70Column 14, rows 15 to 173 panels · 53% of port
Run 71Column 15, rows 1 to 44 panels · 71% of port
Run 72Column 15, rows 5 to 84 panels · 71% of port
Run 73Column 15, rows 9 to 113 panels · 53% of port
Run 74Column 15, rows 12 to 143 panels · 53% of port
Run 75Column 15, rows 15 to 173 panels · 53% of port
Run 76Column 16, rows 1 to 44 panels · 71% of port
Run 77Column 16, rows 5 to 84 panels · 71% of port
Run 78Column 16, rows 9 to 113 panels · 53% of port
Run 79Column 16, rows 12 to 143 panels · 53% of port
Run 80Column 16, rows 15 to 173 panels · 53% of port
Run 81Column 17, rows 1 to 44 panels · 71% of port
Run 82Column 17, rows 5 to 84 panels · 71% of port
Run 83Column 17, rows 9 to 113 panels · 53% of port
Run 84Column 17, rows 12 to 143 panels · 53% of port
Run 85Column 17, rows 15 to 173 panels · 53% of port
Run 86Column 18, rows 1 to 44 panels · 71% of port
Run 87Column 18, rows 5 to 84 panels · 71% of port
Run 88Column 18, rows 9 to 113 panels · 53% of port
Run 89Column 18, rows 12 to 143 panels · 53% of port
Run 90Column 18, rows 15 to 173 panels · 53% of port
Run 91Column 19, rows 1 to 44 panels · 71% of port
Run 92Column 19, rows 5 to 84 panels · 71% of port
Run 93Column 19, rows 9 to 113 panels · 53% of port
Run 94Column 19, rows 12 to 143 panels · 53% of port
Run 95Column 19, rows 15 to 173 panels · 53% of port
Run 96Column 20, rows 1 to 44 panels · 71% of port
Run 97Column 20, rows 5 to 84 panels · 71% of port
Run 98Column 20, rows 9 to 113 panels · 53% of port
Run 99Column 20, rows 12 to 143 panels · 53% of port
Run 100Column 20, rows 15 to 173 panels · 53% of port
Run 101Column 21, rows 1 to 44 panels · 71% of port
Run 102Column 21, rows 5 to 84 panels · 71% of port
Run 103Column 21, rows 9 to 113 panels · 53% of port
Run 104Column 21, rows 12 to 143 panels · 53% of port
Run 105Column 21, rows 15 to 173 panels · 53% of port
Run 106Column 22, rows 1 to 44 panels · 71% of port
Run 107Column 22, rows 5 to 84 panels · 71% of port
Run 108Column 22, rows 9 to 113 panels · 53% of port
Run 109Column 22, rows 12 to 143 panels · 53% of port
Run 110Column 22, rows 15 to 173 panels · 53% of port
Run 111Column 23, rows 1 to 44 panels · 71% of port
Run 112Column 23, rows 5 to 84 panels · 71% of port
Run 113Column 23, rows 9 to 113 panels · 53% of port
Run 114Column 23, rows 12 to 143 panels · 53% of port
Run 115Column 23, rows 15 to 173 panels · 53% of port
Run 116Column 24, rows 1 to 44 panels · 71% of port
Run 117Column 24, rows 5 to 84 panels · 71% of port
Run 118Column 24, rows 9 to 113 panels · 53% of port
Run 119Column 24, rows 12 to 143 panels · 53% of port
Run 120Column 24, rows 15 to 173 panels · 53% of port
Run 121Column 25, rows 1 to 44 panels · 71% of port
Run 122Column 25, rows 5 to 84 panels · 71% of port
Run 123Column 25, rows 9 to 113 panels · 53% of port
Run 124Column 25, rows 12 to 143 panels · 53% of port
Run 125Column 25, rows 15 to 173 panels · 53% of port
Run 126Column 26, rows 1 to 44 panels · 71% of port
Run 127Column 26, rows 5 to 84 panels · 71% of port
Run 128Column 26, rows 9 to 113 panels · 53% of port
Run 129Column 26, rows 12 to 143 panels · 53% of port
Run 130Column 26, rows 15 to 173 panels · 53% of port
Run 131Column 27, rows 1 to 44 panels · 71% of port
Run 132Column 27, rows 5 to 84 panels · 71% of port
Run 133Column 27, rows 9 to 113 panels · 53% of port
Run 134Column 27, rows 12 to 143 panels · 53% of port
Run 135Column 27, rows 15 to 173 panels · 53% of port
Run 136Column 28, rows 1 to 44 panels · 71% of port
Run 137Column 28, rows 5 to 84 panels · 71% of port
Run 138Column 28, rows 9 to 113 panels · 53% of port
Run 139Column 28, rows 12 to 143 panels · 53% of port
Run 140Column 28, rows 15 to 173 panels · 53% of port
Run 141Column 29, rows 1 to 44 panels · 71% of port
Run 142Column 29, rows 5 to 84 panels · 71% of port
Run 143Column 29, rows 9 to 113 panels · 53% of port
Run 144Column 29, rows 12 to 143 panels · 53% of port
Run 145Column 29, rows 15 to 173 panels · 53% of port
Run 146Column 30, rows 1 to 44 panels · 71% of port
Run 147Column 30, rows 5 to 84 panels · 71% of port
Run 148Column 30, rows 9 to 113 panels · 53% of port
Run 149Column 30, rows 12 to 143 panels · 53% of port
Run 150Column 30, rows 15 to 173 panels · 53% of port
Run 151Column 31, rows 1 to 44 panels · 71% of port
Run 152Column 31, rows 5 to 84 panels · 71% of port
Run 153Column 31, rows 9 to 113 panels · 53% of port
Run 154Column 31, rows 12 to 143 panels · 53% of port
Run 155Column 31, rows 15 to 173 panels · 53% of port
Run 156Column 32, rows 1 to 44 panels · 71% of port
Run 157Column 32, rows 5 to 84 panels · 71% of port
Run 158Column 32, rows 9 to 113 panels · 53% of port
Run 159Column 32, rows 12 to 143 panels · 53% of port
Run 160Column 32, rows 15 to 173 panels · 53% of port
Run 161Column 33, rows 1 to 44 panels · 71% of port
Run 162Column 33, rows 5 to 84 panels · 71% of port
Run 163Column 33, rows 9 to 113 panels · 53% of port
Run 164Column 33, rows 12 to 143 panels · 53% of port
Run 165Column 33, rows 15 to 173 panels · 53% of port
Run 166Column 34, rows 1 to 44 panels · 71% of port
Run 167Column 34, rows 5 to 84 panels · 71% of port
Run 168Column 34, rows 9 to 113 panels · 53% of port
Run 169Column 34, rows 12 to 143 panels · 53% of port
Run 170Column 34, rows 15 to 173 panels · 53% of port

Power runs 7 circuits · up to 85 panels/circuit · 18.5 kW max · 1× distro

Circuit 1Columns 1 to 5, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L1
Circuit 2Columns 6 to 10, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L2
Circuit 3Columns 11 to 15, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L3
Circuit 4Columns 16 to 20, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L1
Circuit 5Columns 21 to 25, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L2
Circuit 6Columns 26 to 30, snake up and down, hops right85 panels · 2,720 W · 92% · Distro 1 · L3
Circuit 7Columns 31 to 34, snake up and down, hops right68 panels · 2,176 W · 74% · Distro 1 · L1
PatchDistro 1: circuits 1 to 7 (L1×3 L2×2 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,272 kg over 8.16 × 4.59 m, about 34 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 92 panels per 16 A / 230 V circuit (32 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 5 columns need 7 circuits (single columns would need 34, full rows 17).
  5. openPower for a permanent install comes as 7 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 4 panels per run, giving 170 runs, each looped back to a B port on a second unit, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 1326 tags · 170 data runs · 7 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

578 pcsChristie MicroTiles 0.75 S60 tiles34×17 wall, 8.2×4.6 m
29 pcsSpare tilesone-off rate 5%
24 pcsSpare receiving cards
24 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,272 kg, about 34 kg/m²

Power 0/2 done

7 pcsHouse circuits (16 A / 230 V)18.5 kW max · ~9.2 kW typical content · from the building's board
629 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

34 pcsNovaStar VX1000340/340 ports used (A and B, 17 + 17 units)
340 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
636 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Christie panels

The MicroTiles LED series has 6 panels: the Christie MicroTiles LED series compared.

Where this panel sits

This sheet is listed under Christie LED panels, the 0.9 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.