Christie MicroTiles 1.25 S40 · 1.25 mm

This sheet gives the datasheet figures for the Christie MicroTiles 1.25 S40, a 1.25 mm LED panel in a 240 × 270 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerChristie, MicroTiles LED series
Pixel pitch1.25 mm
Cabinet size240 × 270 × 85 mm
Pixels per cabinet192 × 216 (41,472 px)
Weight2.2 kg (34 kg/m²)
Max power, full white75 W (1157 W/m²)
Typical power23 W
Refresh rate3,840 Hz
Brightness1,000 nits
Viewing angle (H / V)160° / 140°
Optical figuresbrightness calibrated; refresh given as up to 3,840 Hz at 60 Hz input
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly20 (our packing assumption)

Source: Christie: MicroTiles LED 1.25 mm data sheet, retrieved 2026-09-17. Fixed-install tile in the 8:9 MicroTiles format, fed at 48 V from a remote power supply or by Power over Ethernet, all service from the front, IP30, 2.2 kg per tile and 34 kg/m² (49.4 kg/m² installed with the QuickMount). Sheet gives 23 W typical and 75 W maximum per tile; heat 79 and 256 BTU/h. The house circuits feed the remote supply rack, not the tiles. No hanging limit published, so the hang figure is a conservative placeholder.

Worked example: a 34 × 17 wall (16:9)

34 columns by 17 rows of this tile makes a 8.16 × 4.59 m wall, the closest this cabinet gets to 16:9, at 6,528 × 3,672 pixels (23.97 MP): 578 panels plus 29 spares at the one-off rate. It weighs about 1,272 kg, carried by the structure it is mounted on.

On European power it draws 43.4 kW at full white (13.3 kW on typical content), which at an 80% derate is 17 × 16 A / 230 V circuits. Data comes to 68 runs at up to 12 panels per port, worst run 57% loaded, fitting 14 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

wall-mounted: the structure carries 1,272 kg8.16 m (6,528 px)4.59 m (3,672 px)43.4 kW max · 17× 16 A / 230 V · 68 runs on 14× NovaStar VX1000

Main: 34 × 17 Christie MicroTiles 1.25 S40

Size
8.16 × 4.59 m
Diagonal
369 in
Area
37.5 m²
Resolution
6,528 × 3,672 px
Pixels
23.97 M px
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
43.4 kW max, 13.3 kW typical, 17 circuits
Data
68 runs on 14 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainChristie MicroTiles 1.25 S4034 × 178.16 × 4.59 m · 369 in6,528 × 3,672 pxwall-mounted
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
43.4 kW max, 13.3 kW typical, 17 circuits
Data
68 runs on 14 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 68 runs · up to 12 panels per run at 80% · worst 57% · 14× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 99 panels · 57% of port
Run 2Column 1, rows 10 to 178 panels · 51% of port
Run 3Column 2, rows 1 to 99 panels · 57% of port
Run 4Column 2, rows 10 to 178 panels · 51% of port
Run 5Column 3, rows 1 to 99 panels · 57% of port
Run 6Column 3, rows 10 to 178 panels · 51% of port
Run 7Column 4, rows 1 to 99 panels · 57% of port
Run 8Column 4, rows 10 to 178 panels · 51% of port
Run 9Column 5, rows 1 to 99 panels · 57% of port
Run 10Column 5, rows 10 to 178 panels · 51% of port
Run 11Column 6, rows 1 to 99 panels · 57% of port
Run 12Column 6, rows 10 to 178 panels · 51% of port
Run 13Column 7, rows 1 to 99 panels · 57% of port
Run 14Column 7, rows 10 to 178 panels · 51% of port
Run 15Column 8, rows 1 to 99 panels · 57% of port
Run 16Column 8, rows 10 to 178 panels · 51% of port
Run 17Column 9, rows 1 to 99 panels · 57% of port
Run 18Column 9, rows 10 to 178 panels · 51% of port
Run 19Column 10, rows 1 to 99 panels · 57% of port
Run 20Column 10, rows 10 to 178 panels · 51% of port
Run 21Column 11, rows 1 to 99 panels · 57% of port
Run 22Column 11, rows 10 to 178 panels · 51% of port
Run 23Column 12, rows 1 to 99 panels · 57% of port
Run 24Column 12, rows 10 to 178 panels · 51% of port
Run 25Column 13, rows 1 to 99 panels · 57% of port
Run 26Column 13, rows 10 to 178 panels · 51% of port
Run 27Column 14, rows 1 to 99 panels · 57% of port
Run 28Column 14, rows 10 to 178 panels · 51% of port
Run 29Column 15, rows 1 to 99 panels · 57% of port
Run 30Column 15, rows 10 to 178 panels · 51% of port
Run 31Column 16, rows 1 to 99 panels · 57% of port
Run 32Column 16, rows 10 to 178 panels · 51% of port
Run 33Column 17, rows 1 to 99 panels · 57% of port
Run 34Column 17, rows 10 to 178 panels · 51% of port
Run 35Column 18, rows 1 to 99 panels · 57% of port
Run 36Column 18, rows 10 to 178 panels · 51% of port
Run 37Column 19, rows 1 to 99 panels · 57% of port
Run 38Column 19, rows 10 to 178 panels · 51% of port
Run 39Column 20, rows 1 to 99 panels · 57% of port
Run 40Column 20, rows 10 to 178 panels · 51% of port
Run 41Column 21, rows 1 to 99 panels · 57% of port
Run 42Column 21, rows 10 to 178 panels · 51% of port
Run 43Column 22, rows 1 to 99 panels · 57% of port
Run 44Column 22, rows 10 to 178 panels · 51% of port
Run 45Column 23, rows 1 to 99 panels · 57% of port
Run 46Column 23, rows 10 to 178 panels · 51% of port
Run 47Column 24, rows 1 to 99 panels · 57% of port
Run 48Column 24, rows 10 to 178 panels · 51% of port
Run 49Column 25, rows 1 to 99 panels · 57% of port
Run 50Column 25, rows 10 to 178 panels · 51% of port
Run 51Column 26, rows 1 to 99 panels · 57% of port
Run 52Column 26, rows 10 to 178 panels · 51% of port
Run 53Column 27, rows 1 to 99 panels · 57% of port
Run 54Column 27, rows 10 to 178 panels · 51% of port
Run 55Column 28, rows 1 to 99 panels · 57% of port
Run 56Column 28, rows 10 to 178 panels · 51% of port
Run 57Column 29, rows 1 to 99 panels · 57% of port
Run 58Column 29, rows 10 to 178 panels · 51% of port
Run 59Column 30, rows 1 to 99 panels · 57% of port
Run 60Column 30, rows 10 to 178 panels · 51% of port
Run 61Column 31, rows 1 to 99 panels · 57% of port
Run 62Column 31, rows 10 to 178 panels · 51% of port
Run 63Column 32, rows 1 to 99 panels · 57% of port
Run 64Column 32, rows 10 to 178 panels · 51% of port
Run 65Column 33, rows 1 to 99 panels · 57% of port
Run 66Column 33, rows 10 to 178 panels · 51% of port
Run 67Column 34, rows 1 to 99 panels · 57% of port
Run 68Column 34, rows 10 to 178 panels · 51% of port

Power runs 17 circuits · up to 34 panels/circuit · 43.4 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L3
Circuit 7Columns 13 to 14, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 8Columns 15 to 16, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
Circuit 9Columns 17 to 18, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L3
Circuit 10Columns 19 to 20, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 11Columns 21 to 22, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
Circuit 12Columns 23 to 24, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L3
Circuit 13Columns 25 to 26, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 14Columns 27 to 28, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
Circuit 15Columns 29 to 30, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L3
Circuit 16Columns 31 to 32, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L1
Circuit 17Columns 33 to 34, snake up and down, hops right34 panels · 2,550 W · 87% · Distro 1 · L2
PatchDistro 1: circuits 1 to 17 (L1×6 L2×6 L3×5)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,272 kg over 8.16 × 4.59 m, about 34 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 39 panels per 16 A / 230 V circuit (75 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 17 circuits (single columns would need 34, full rows 17).
  5. openPower for a permanent install comes as 17 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 12 panels per run, giving 68 runs, each looped back to a B port on a second unit, worst run 57%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 1224 tags · 68 data runs · 17 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

578 pcsChristie MicroTiles 1.25 S40 tiles34×17 wall, 8.2×4.6 m
29 pcsSpare tilesone-off rate 5%
24 pcsSpare receiving cards
24 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,272 kg, about 34 kg/m²

Power 0/2 done

17 pcsHouse circuits (16 A / 230 V)43.4 kW max · ~13.3 kW typical content · from the building's board
618 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

14 pcsNovaStar VX1000136/140 ports used (A and B, 7 + 7 units)
136 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
636 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Christie panels

The MicroTiles LED series has 6 panels: the Christie MicroTiles LED series compared.

Where this panel sits

This sheet is listed under Christie LED panels, the 1.2 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.