Main: 34 × 17 Christie MicroTiles 1.5 S40
- Size
- 8.16 × 4.59 m
- Diagonal
- 369 in
- Area
- 37.5 m²
- Resolution
- 5,440 × 3,060 px
- Pixels
- 16.65 M px
- Panels
- 578 + 29 spares
- Weight
- 1,272 kg panels only
- Power
- 43.4 kW max, 13.3 kW typical, 17 circuits
- Data
- 34 runs on 8 processors at 60 Hz 8-bit
This is a live example. Change the panel and the size in the steps and every figure recomputes.
| Main | Christie MicroTiles 1.5 S40 | 34 × 17 | 8.16 × 4.59 m · 369 in | 5,440 × 3,060 px | wall-mounted |
- Panels
- 578 + 29 spares
- Weight
- 1,272 kg panels only
- Power
- 43.4 kW max, 13.3 kW typical, 17 circuits
- Data
- 34 runs on 8 processors at 60 Hz 8-bit
The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 34 runs · up to 18 panels per run at 80% · worst 75% · 8× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
| Run 1 | Column 1 | 17 panels · 75% of port |
| Run 2 | Column 2 | 17 panels · 75% of port |
| Run 3 | Column 3 | 17 panels · 75% of port |
| Run 4 | Column 4 | 17 panels · 75% of port |
| Run 5 | Column 5 | 17 panels · 75% of port |
| Run 6 | Column 6 | 17 panels · 75% of port |
| Run 7 | Column 7 | 17 panels · 75% of port |
| Run 8 | Column 8 | 17 panels · 75% of port |
| Run 9 | Column 9 | 17 panels · 75% of port |
| Run 10 | Column 10 | 17 panels · 75% of port |
| Run 11 | Column 11 | 17 panels · 75% of port |
| Run 12 | Column 12 | 17 panels · 75% of port |
| Run 13 | Column 13 | 17 panels · 75% of port |
| Run 14 | Column 14 | 17 panels · 75% of port |
| Run 15 | Column 15 | 17 panels · 75% of port |
| Run 16 | Column 16 | 17 panels · 75% of port |
| Run 17 | Column 17 | 17 panels · 75% of port |
| Run 18 | Column 18 | 17 panels · 75% of port |
| Run 19 | Column 19 | 17 panels · 75% of port |
| Run 20 | Column 20 | 17 panels · 75% of port |
| Run 21 | Column 21 | 17 panels · 75% of port |
| Run 22 | Column 22 | 17 panels · 75% of port |
| Run 23 | Column 23 | 17 panels · 75% of port |
| Run 24 | Column 24 | 17 panels · 75% of port |
| Run 25 | Column 25 | 17 panels · 75% of port |
| Run 26 | Column 26 | 17 panels · 75% of port |
| Run 27 | Column 27 | 17 panels · 75% of port |
| Run 28 | Column 28 | 17 panels · 75% of port |
| Run 29 | Column 29 | 17 panels · 75% of port |
| Run 30 | Column 30 | 17 panels · 75% of port |
| Run 31 | Column 31 | 17 panels · 75% of port |
| Run 32 | Column 32 | 17 panels · 75% of port |
| Run 33 | Column 33 | 17 panels · 75% of port |
| Run 34 | Column 34 | 17 panels · 75% of port |
Power runs 17 circuits · up to 34 panels/circuit · 43.4 kW max · 1× distro
| Circuit 1 | Columns 1 to 2, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 2 | Columns 3 to 4, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Circuit 3 | Columns 5 to 6, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L3 |
| Circuit 4 | Columns 7 to 8, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 5 | Columns 9 to 10, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Circuit 6 | Columns 11 to 12, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L3 |
| Circuit 7 | Columns 13 to 14, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 8 | Columns 15 to 16, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Circuit 9 | Columns 17 to 18, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L3 |
| Circuit 10 | Columns 19 to 20, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 11 | Columns 21 to 22, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Circuit 12 | Columns 23 to 24, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L3 |
| Circuit 13 | Columns 25 to 26, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 14 | Columns 27 to 28, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Circuit 15 | Columns 29 to 30, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L3 |
| Circuit 16 | Columns 31 to 32, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L1 |
| Circuit 17 | Columns 33 to 34, snake up and down, hops right | 34 panels · 2,550 W · 87% · Distro 1 · L2 |
| Patch | Distro 1: circuits 1 to 17 (L1×6 L2×6 L3×5) | |
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
- openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
- ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,272 kg over 8.16 × 4.59 m, about 34 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
- ✓ confirmedCircuits sized on max load (full white) at 80% derate: 39 panels per 16 A / 230 V circuit (75 W/panel). Typical draw shown separately for the venue/generator ask.
- ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 17 circuits (single columns would need 34, full rows 17).
- openPower for a permanent install comes as 17 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
- ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
- ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 18 panels per run, giving 34 runs, each looped back to a B port on a second unit, worst run 75%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
- ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
- openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
- openHome runs cut at run distance + wall height + 5 m service loop.
- openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
- ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
- openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 1190 tags · 34 data runs · 17 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Copy tags as CSV 🔒The tag list, your own label format, and the CSV for a label printer are a Solo feature.
Panels 0/4 done
| 578 pcs | Christie MicroTiles 1.5 S40 tiles | 34×17 wall, 8.2×4.6 m | ||
| 29 pcs | Spare tiles | one-off rate 5% | ||
| 24 pcs | Spare receiving cards | |||
| 24 pcs | Spare PSUs |
Rigging 0/1 done
| 1 set | Mounting structure | site-specific, not derived; carries 1,272 kg, about 34 kg/m² |
Power 0/2 done
| 17 pcs | House circuits (16 A / 230 V) | 43.4 kW max · ~13.3 kW typical content · from the building's board | ||
| 618 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
Data & control 0/3 done
| 8 pcs | NovaStar VX1000 | 68/80 ports used (A and B, 4 + 4 units) | ||
| 68 pcs | Cat6A home runs, ~40 m | run + height + 5 m loop, A and B | ||
| 636 pcs | Cat6 panel jumpers | incl. 10% spare |