Christie MicroTiles 1.0 S80 · 1 mm

This sheet gives the datasheet figures for the Christie MicroTiles 1.0 S80, a 1 mm LED panel in a 240 × 270 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerChristie, MicroTiles LED series
Pixel pitch1 mm
Cabinet size240 × 270 × 85 mm
Pixels per cabinet240 × 270 (64,800 px)
Weight2.2 kg (34 kg/m²)
Max power, full white43 W (664 W/m²)
Typical power25 W
Refresh rate3,840 Hz
Brightness1,500 nits
Viewing angle (H / V)160° / 140°
Optical figuresbrightness calibrated; refresh given as up to 3,840 Hz
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly20 (our packing assumption)

Source: Christie: MicroTiles LED 0.75 mm and 1.0 mm data sheet, retrieved 2026-09-17. Fixed-install tile in the 8:9 MicroTiles format, fed at 48 V from a remote power supply or by Power over Ethernet, all service from the front, IP30, 34 kg/m² (49.4 kg/m² installed with the QuickMount). Sheet gives 25 W typical and 43 W maximum per tile; heat 85 and 147 BTU/h. The house circuits feed the remote supply rack, not the tiles. No hanging limit published, so the hang figure is a conservative placeholder.

Worked example: a 34 × 17 wall (16:9)

34 columns by 17 rows of this tile makes a 8.16 × 4.59 m wall, the closest this cabinet gets to 16:9, at 8,160 × 4,590 pixels (37.45 MP): 578 panels plus 29 spares at the one-off rate. It weighs about 1,272 kg, carried by the structure it is mounted on.

On European power it draws 24.9 kW at full white (14.5 kW on typical content), which at an 80% derate is 9 × 16 A / 230 V circuits. Data comes to 102 runs at up to 8 panels per port, worst run 60% loaded, fitting 22 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

wall-mounted: the structure carries 1,272 kg8.16 m (8,160 px)4.59 m (4,590 px)24.9 kW max · 9× 16 A / 230 V · 102 runs on 22× NovaStar VX1000

Main: 34 × 17 Christie MicroTiles 1.0 S80

Size
8.16 × 4.59 m
Diagonal
369 in
Area
37.5 m²
Resolution
8,160 × 4,590 px
Pixels
37.45 M px
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
24.9 kW max, 14.5 kW typical, 9 circuits
Data
102 runs on 22 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainChristie MicroTiles 1.0 S8034 × 178.16 × 4.59 m · 369 in8,160 × 4,590 pxwall-mounted
Panels
578 + 29 spares
Weight
1,272 kg panels only
Power
24.9 kW max, 14.5 kW typical, 9 circuits
Data
102 runs on 22 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 102 runs · up to 8 panels per run at 80% · worst 60% · 22× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 66 panels · 60% of port
Run 2Column 1, rows 7 to 126 panels · 60% of port
Run 3Column 1, rows 13 to 175 panels · 50% of port
Run 4Column 2, rows 1 to 66 panels · 60% of port
Run 5Column 2, rows 7 to 126 panels · 60% of port
Run 6Column 2, rows 13 to 175 panels · 50% of port
Run 7Column 3, rows 1 to 66 panels · 60% of port
Run 8Column 3, rows 7 to 126 panels · 60% of port
Run 9Column 3, rows 13 to 175 panels · 50% of port
Run 10Column 4, rows 1 to 66 panels · 60% of port
Run 11Column 4, rows 7 to 126 panels · 60% of port
Run 12Column 4, rows 13 to 175 panels · 50% of port
Run 13Column 5, rows 1 to 66 panels · 60% of port
Run 14Column 5, rows 7 to 126 panels · 60% of port
Run 15Column 5, rows 13 to 175 panels · 50% of port
Run 16Column 6, rows 1 to 66 panels · 60% of port
Run 17Column 6, rows 7 to 126 panels · 60% of port
Run 18Column 6, rows 13 to 175 panels · 50% of port
Run 19Column 7, rows 1 to 66 panels · 60% of port
Run 20Column 7, rows 7 to 126 panels · 60% of port
Run 21Column 7, rows 13 to 175 panels · 50% of port
Run 22Column 8, rows 1 to 66 panels · 60% of port
Run 23Column 8, rows 7 to 126 panels · 60% of port
Run 24Column 8, rows 13 to 175 panels · 50% of port
Run 25Column 9, rows 1 to 66 panels · 60% of port
Run 26Column 9, rows 7 to 126 panels · 60% of port
Run 27Column 9, rows 13 to 175 panels · 50% of port
Run 28Column 10, rows 1 to 66 panels · 60% of port
Run 29Column 10, rows 7 to 126 panels · 60% of port
Run 30Column 10, rows 13 to 175 panels · 50% of port
Run 31Column 11, rows 1 to 66 panels · 60% of port
Run 32Column 11, rows 7 to 126 panels · 60% of port
Run 33Column 11, rows 13 to 175 panels · 50% of port
Run 34Column 12, rows 1 to 66 panels · 60% of port
Run 35Column 12, rows 7 to 126 panels · 60% of port
Run 36Column 12, rows 13 to 175 panels · 50% of port
Run 37Column 13, rows 1 to 66 panels · 60% of port
Run 38Column 13, rows 7 to 126 panels · 60% of port
Run 39Column 13, rows 13 to 175 panels · 50% of port
Run 40Column 14, rows 1 to 66 panels · 60% of port
Run 41Column 14, rows 7 to 126 panels · 60% of port
Run 42Column 14, rows 13 to 175 panels · 50% of port
Run 43Column 15, rows 1 to 66 panels · 60% of port
Run 44Column 15, rows 7 to 126 panels · 60% of port
Run 45Column 15, rows 13 to 175 panels · 50% of port
Run 46Column 16, rows 1 to 66 panels · 60% of port
Run 47Column 16, rows 7 to 126 panels · 60% of port
Run 48Column 16, rows 13 to 175 panels · 50% of port
Run 49Column 17, rows 1 to 66 panels · 60% of port
Run 50Column 17, rows 7 to 126 panels · 60% of port
Run 51Column 17, rows 13 to 175 panels · 50% of port
Run 52Column 18, rows 1 to 66 panels · 60% of port
Run 53Column 18, rows 7 to 126 panels · 60% of port
Run 54Column 18, rows 13 to 175 panels · 50% of port
Run 55Column 19, rows 1 to 66 panels · 60% of port
Run 56Column 19, rows 7 to 126 panels · 60% of port
Run 57Column 19, rows 13 to 175 panels · 50% of port
Run 58Column 20, rows 1 to 66 panels · 60% of port
Run 59Column 20, rows 7 to 126 panels · 60% of port
Run 60Column 20, rows 13 to 175 panels · 50% of port
Run 61Column 21, rows 1 to 66 panels · 60% of port
Run 62Column 21, rows 7 to 126 panels · 60% of port
Run 63Column 21, rows 13 to 175 panels · 50% of port
Run 64Column 22, rows 1 to 66 panels · 60% of port
Run 65Column 22, rows 7 to 126 panels · 60% of port
Run 66Column 22, rows 13 to 175 panels · 50% of port
Run 67Column 23, rows 1 to 66 panels · 60% of port
Run 68Column 23, rows 7 to 126 panels · 60% of port
Run 69Column 23, rows 13 to 175 panels · 50% of port
Run 70Column 24, rows 1 to 66 panels · 60% of port
Run 71Column 24, rows 7 to 126 panels · 60% of port
Run 72Column 24, rows 13 to 175 panels · 50% of port
Run 73Column 25, rows 1 to 66 panels · 60% of port
Run 74Column 25, rows 7 to 126 panels · 60% of port
Run 75Column 25, rows 13 to 175 panels · 50% of port
Run 76Column 26, rows 1 to 66 panels · 60% of port
Run 77Column 26, rows 7 to 126 panels · 60% of port
Run 78Column 26, rows 13 to 175 panels · 50% of port
Run 79Column 27, rows 1 to 66 panels · 60% of port
Run 80Column 27, rows 7 to 126 panels · 60% of port
Run 81Column 27, rows 13 to 175 panels · 50% of port
Run 82Column 28, rows 1 to 66 panels · 60% of port
Run 83Column 28, rows 7 to 126 panels · 60% of port
Run 84Column 28, rows 13 to 175 panels · 50% of port
Run 85Column 29, rows 1 to 66 panels · 60% of port
Run 86Column 29, rows 7 to 126 panels · 60% of port
Run 87Column 29, rows 13 to 175 panels · 50% of port
Run 88Column 30, rows 1 to 66 panels · 60% of port
Run 89Column 30, rows 7 to 126 panels · 60% of port
Run 90Column 30, rows 13 to 175 panels · 50% of port
Run 91Column 31, rows 1 to 66 panels · 60% of port
Run 92Column 31, rows 7 to 126 panels · 60% of port
Run 93Column 31, rows 13 to 175 panels · 50% of port
Run 94Column 32, rows 1 to 66 panels · 60% of port
Run 95Column 32, rows 7 to 126 panels · 60% of port
Run 96Column 32, rows 13 to 175 panels · 50% of port
Run 97Column 33, rows 1 to 66 panels · 60% of port
Run 98Column 33, rows 7 to 126 panels · 60% of port
Run 99Column 33, rows 13 to 175 panels · 50% of port
Run 100Column 34, rows 1 to 66 panels · 60% of port
Run 101Column 34, rows 7 to 126 panels · 60% of port
Run 102Column 34, rows 13 to 175 panels · 50% of port

Power runs 9 circuits · up to 68 panels/circuit · 24.9 kW max · 1× distro

Circuit 1Columns 1 to 4, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L1
Circuit 2Columns 5 to 8, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L2
Circuit 3Columns 9 to 12, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L3
Circuit 4Columns 13 to 16, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L1
Circuit 5Columns 17 to 20, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L2
Circuit 6Columns 21 to 24, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L3
Circuit 7Columns 25 to 28, snake up and down, hops right68 panels · 2,924 W · 99% · Distro 1 · L1
Circuit 8Columns 29 to 31, snake up and down, hops right51 panels · 2,193 W · 74% · Distro 1 · L2
Circuit 9Columns 32 to 34, snake up and down, hops right51 panels · 2,193 W · 74% · Distro 1 · L3
PatchDistro 1: circuits 1 to 9 (L1×3 L2×3 L3×3)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,272 kg over 8.16 × 4.59 m, about 34 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 68 panels per 16 A / 230 V circuit (43 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 4 columns need 9 circuits (single columns would need 34, full rows 17).
  5. openPower for a permanent install comes as 9 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 8 panels per run, giving 102 runs, each looped back to a B port on a second unit, worst run 60%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 1258 tags · 102 data runs · 9 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

578 pcsChristie MicroTiles 1.0 S80 tiles34×17 wall, 8.2×4.6 m
29 pcsSpare tilesone-off rate 5%
24 pcsSpare receiving cards
24 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,272 kg, about 34 kg/m²

Power 0/2 done

9 pcsHouse circuits (16 A / 230 V)24.9 kW max · ~14.5 kW typical content · from the building's board
626 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

22 pcsNovaStar VX1000204/220 ports used (A and B, 11 + 11 units)
204 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
636 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Christie panels

The MicroTiles LED series has 6 panels: the Christie MicroTiles LED series compared.

Where this panel sits

This sheet is listed under Christie LED panels, the 0.9 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.