ROE Visual Carbon CB8 MkII · 8.33 mm

This sheet gives the datasheet figures for the ROE Visual Carbon CB8 MkII, a 8.33 mm LED panel in a 600 × 1200 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerROE Visual, Carbon series
Pixel pitch8.33 mm
Cabinet size600 × 1200 × 79 mm
Pixels per cabinet72 × 144 (10,368 px)
Weight11 kg (15 kg/m²)
Max power, full white530 W (736 W/m²)
Typical power260 W
Refresh rate3,840 Hz
Brightness6,000 nits
Viewing angle (H / V)140° / 110°
Max hang12 panels
Hanging bar weight1-wide 3 kg, 2-wide 6.1 kg
Hanging bar sourceCarbon hanging bars 589 mm (3.0 kg) and 1,189 mm (6.1 kg) from the first-generation CB5 user manual (2018), applied to the MkII since its documents publish no bar weight; no 3-wide bar is listed
Panels per dolly6 (our packing assumption)

Source: ROE Visual: Carbon MkII specifications (Jan 2023), retrieved 2026-09-01. 23% transparency, an open-frame tile, unlike the solid CB3/CB5.

Worked example: a 13 × 4 wall (16:10)

13 columns by 4 rows of this tile makes a 7.80 × 4.80 m wall, the closest this cabinet gets to 16:10, at 936 × 576 pixels (0.54 MP): 52 panels plus 3 spares at the one-off rate. It weighs about 612 kg including bumpers, around 245 kg across each of 3 points.

On European power it draws 27.6 kW at full white (13.5 kW on typical content), which at an 80% derate is 12 × 16 A / 230 V circuits. Data comes to 2 runs at up to 50 panels per port, worst run 45% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R145%R238%2w2w2w2w2w2w1w~245 kg~245 kg~245 kg7.80 m (936 px)4.80 m (576 px)27.6 kW max · 12× 16 A / 230 V · 2 runs on 1× NovaStar VX1000

Main: 13 × 4 ROE Visual CB8 MkII

Size
7.80 × 4.80 m
Area
37.4 m²
Resolution
936 × 576 px
Pixels
0.54 M px
Panels
52 + 3 spares
Weight
612 kg incl. bumpers
Power
27.6 kW max, 13.5 kW typical, 12 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
3.1 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainROE Visual CB8 MkII13 × 47.80 × 4.80 m936 × 576 pxflown
Panels
52 + 3 spares
Weight
612 kg incl. bumpers
Power
27.6 kW max, 13.5 kW typical, 12 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
3.1 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 2 runs · up to 50 panels per run at 80% · worst 45% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 728 panels · 45% of port
Run 2Columns 8 to 1324 panels · 38% of port

Power runs 12 circuits · up to 5 panels/circuit · 27.6 kW max · 1× distro

Circuit 1Row 1, columns 1 to 5, left to right (rear)5 panels · 2,650 W · 90% · Distro 1 · L1
Circuit 2Row 1, columns 6 to 9, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L2
Circuit 3Row 1, columns 10 to 13, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L3
Circuit 4Row 2, columns 1 to 5, left to right (rear)5 panels · 2,650 W · 90% · Distro 1 · L1
Circuit 5Row 2, columns 6 to 9, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L2
Circuit 6Row 2, columns 10 to 13, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L3
Circuit 7Row 3, columns 1 to 5, left to right (rear)5 panels · 2,650 W · 90% · Distro 1 · L1
Circuit 8Row 3, columns 6 to 9, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L2
Circuit 9Row 3, columns 10 to 13, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L3
Circuit 10Row 4, columns 1 to 5, left to right (rear)5 panels · 2,650 W · 90% · Distro 1 · L1
Circuit 11Row 4, columns 6 to 9, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L2
Circuit 12Row 4, columns 10 to 13, left to right (rear)4 panels · 2,120 W · 72% · Distro 1 · L3
PatchDistro 1: circuits 1 to 12 (L1×4 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. ✓ confirmedHanging bar weights from ROE Visual: 1-wide 3 kg, 2-wide 6.1 kg; 3-wide not listed, so your standard 35 kg applies. Carbon hanging bars 589 mm (3.0 kg) and 1,189 mm (6.1 kg) from the first-generation CB5 user manual (2018), applied to the MkII since its documents publish no bar weight; no 3-wide bar is listed.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 5 panels per 16 A / 230 V circuit (530 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Full rows fed left to right need 12 circuits against 13 vertical; rows win here.
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 50 panels per run, giving 2 runs, worst run 45%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 6 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 104 tags · 2 data runs · 12 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

52 pcsROE Carbon CB8 MkII tiles13×4 wall, 7.8×4.8 m
3 pcsSpare tilesone-off rate 5%
3 pcsSpare receiving cards
3 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 6.1 kg each
1 pcs1-wide bumpersfrom your stock · 3 kg each
3 pcsChain hoists, 1 tpoint load ~245 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro27.6 kW max · ~13.5 kW typical content
12 pcsFeeder lines to wall (16 A / 230 V)~30 m each
44 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10002/10 ports used
2 pcsCat6A home runs, ~40 mrun + height + 5 m loop
58 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

10 pcsPanel dollies6 tiles per dolly
1 pcsBumper cases8 per case
2 pcsCable trunks~116 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
3.1 mTruck deck, linear15 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other ROE Visual panels

The Carbon series has 3 panels: the ROE Carbon series compared.

Where this panel sits

This sheet is listed under ROE Visual LED panels, the 7 to 9 mm pixel pitch class, rental and touring LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.