ROE Visual Carbon CB3 MkII · 3.75 mm

This sheet gives the datasheet figures for the ROE Visual Carbon CB3 MkII, a 3.75 mm LED panel in a 600 × 1200 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerROE Visual, Carbon series
Pixel pitch3.75 mm
Cabinet size600 × 1200 × 79 mm
Pixels per cabinet160 × 320 (51,200 px)
Weight14 kg (19 kg/m²)
Max power, full white600 W (833 W/m²)
Typical power300 W
Refresh rate3,840 Hz
Brightness4,500 nits
Viewing angle (H / V)140° / 110°
Optical figuresblack-LED variant brightness
Max hang12 panels
Hanging bar weight1-wide 3 kg, 2-wide 6.1 kg
Hanging bar sourceCarbon hanging bars 589 mm (3.0 kg) and 1,189 mm (6.1 kg) from the first-generation CB5 user manual (2018), applied to the MkII since its documents publish no bar weight; no 3-wide bar is listed
Panels per dolly6 (our packing assumption)

Source: ROE Visual: Carbon MkII specifications (Jan 2023), retrieved 2026-09-01.

Worked example: a 13 × 4 wall (16:10)

13 columns by 4 rows of this tile makes a 7.80 × 4.80 m wall, the closest this cabinet gets to 16:10, at 2,080 × 1,280 pixels (2.66 MP): 52 panels plus 3 spares at the one-off rate. It weighs about 768 kg including bumpers, around 307 kg across each of 3 points.

On European power it draws 31.2 kW at full white (15.6 kW on typical content), which at an 80% derate is 13 × 16 A / 230 V circuits. Data comes to 7 runs at up to 10 panels per port, worst run 63% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R163%R263%R363%R463%R563%R663%R732%2w2w2w2w2w2w1w~307 kg~307 kg~307 kg7.80 m (2,080 px)4.80 m (1,280 px)31.2 kW max · 13× 16 A / 230 V · 7 runs on 1× NovaStar VX1000

Main: 13 × 4 ROE Visual CB3 MkII

Size
7.80 × 4.80 m
Area
37.4 m²
Resolution
2,080 × 1,280 px
Pixels
2.66 M px
Panels
52 + 3 spares
Weight
768 kg incl. bumpers
Power
31.2 kW max, 15.6 kW typical, 13 circuits
Data
7 runs on 1 processor at 60 Hz 8-bit
Truck
3.3 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainROE Visual CB3 MkII13 × 47.80 × 4.80 m2,080 × 1,280 pxflown
Panels
52 + 3 spares
Weight
768 kg incl. bumpers
Power
31.2 kW max, 15.6 kW typical, 13 circuits
Data
7 runs on 1 processor at 60 Hz 8-bit
Truck
3.3 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 7 runs · up to 10 panels per run at 80% · worst 63% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 28 panels · 63% of port
Run 2Columns 3 to 48 panels · 63% of port
Run 3Columns 5 to 68 panels · 63% of port
Run 4Columns 7 to 88 panels · 63% of port
Run 5Columns 9 to 108 panels · 63% of port
Run 6Columns 11 to 128 panels · 63% of port
Run 7Column 134 panels · 32% of port

Power runs 13 circuits · up to 4 panels/circuit · 31.2 kW max · 1× distro

Circuit 1Column 14 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 2Column 24 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 3Column 34 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 4Column 44 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 5Column 54 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 6Column 64 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 7Column 74 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 8Column 84 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 9Column 94 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 10Column 104 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 11Column 114 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 12Column 124 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 13Column 134 panels · 2,400 W · 82% · Distro 1 · L1
PatchDistro 1: circuits 1 to 13 (L1×5 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. ✓ confirmedHanging bar weights from ROE Visual: 1-wide 3 kg, 2-wide 6.1 kg; 3-wide not listed, so your standard 35 kg applies. Carbon hanging bars 589 mm (3.0 kg) and 1,189 mm (6.1 kg) from the first-generation CB5 user manual (2018), applied to the MkII since its documents publish no bar weight; no 3-wide bar is listed.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 4 panels per 16 A / 230 V circuit (600 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 16).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 10 panels per run, giving 7 runs, worst run 63%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 6 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 104 tags · 7 data runs · 13 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

52 pcsROE Carbon CB3 MkII tiles13×4 wall, 7.8×4.8 m
3 pcsSpare tilesone-off rate 5%
3 pcsSpare receiving cards
3 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 6.1 kg each
1 pcs1-wide bumpersfrom your stock · 3 kg each
3 pcsChain hoists, 1 tpoint load ~307 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro31.2 kW max · ~15.6 kW typical content
13 pcsFeeder lines to wall (16 A / 230 V)~30 m each
43 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10007/10 ports used
7 pcsCat6A home runs, ~40 mrun + height + 5 m loop
58 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

10 pcsPanel dollies6 tiles per dolly
1 pcsBumper cases8 per case
3 pcsCable trunks~121 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
3.3 mTruck deck, linear16 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app