This sheet gives the datasheet figures for the Nanolumens Performance 250 10.4, a 10.417 mm LED panel in a 250 × 250 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.
Spec sheet from the manufacturer datasheet
Manufacturer
Nanolumens, Performance 250 series
Pixel pitch
10.417 mm
Cabinet size
250 × 250 × 139.7 mm
Pixels per cabinet
24 × 24 (576 px)
Weight
2.33 kg (37 kg/m²)
Max power, full white
41.3 W (661 W/m²)
Typical power
12.4 W
Refresh rate
not published
Brightness
5,500 nits
Viewing angle (H / V)
140° / 140°
Optical figures
the sheet gives 178° / 140° maximum and 140° / 140° at half brightness (L50), the figure stored; no refresh rate is printed
Max hang
not published by manufacturer
Hanging bar weight
not published by manufacturer
Panels per dolly
8 (our packing assumption)
Source: Nanolumens: Performance Series spec sheet, retrieved 2026-10-09. Outdoor fixed-install cabinet, the 250 × 250 mm size of the Performance Series, front service, faceted curves. Sheet gives 61.34 W/ft² maximum and 18.40 W/ft² average (660/198 W/m²) and 3.47 kg/ft² (37.4 kg/m²), converted at the 0.0625 m² cabinet. The sheet’s introduction calls every cabinet fully IP67 rated, while the Performance product page says IP65 and front or rear service, where the sheet says front. A décor frame adds 1/2 in to the overall height and width. Headline pitch 10.4 mm; the sheet’s own geometry (250 mm ÷ 24 px) gives 10.417 mm. No hanging limit is published, so the hang figure is a placeholder.
Worked example: a 32 × 18 wall (16:9)
32 columns by 18 rows of this tile makes a 8.00 × 4.50 m wall, the closest this cabinet gets to 16:9, at 768 × 432 pixels (0.33 MP): 576 panels plus 29 spares at the one-off rate. It weighs about 1,342 kg, carried by the structure it is mounted on.
On European power it draws 23.8 kW at full white (7.1 kW on typical content), which at an 80% derate is 11 × 16 A / 230 V circuits. Data comes to 1 runs at up to 902 panels per port, worst run 51% loaded, fitting 2 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.
Main: 32 × 18 Nanolumens Performance 250 10.4
Size
8.00 × 4.50 m
Area
36.0 m²
Resolution
768 × 432 px
Pixels
0.33 M px
Panels
576 + 29 spares
Weight
1,342 kg panels only
Power
23.8 kW max, 7.1 kW typical, 11 circuits
Data
1 runs on 2 processors at 60 Hz 8-bit
This is a live example. Change the panel and the size in the steps and every figure recomputes.
RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
Main
Nanolumens Performance 250 10.4
32 × 18
8.00 × 4.50 m
768 × 432 px
wall-mounted
Panels
576 + 29 spares
Weight
1,342 kg panels only
Power
23.8 kW max, 7.1 kW typical, 11 circuits
Data
1 runs on 2 processors at 60 Hz 8-bit
The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 1 runs · up to 902 panels per run at 80% · worst 51% · 2× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
Run 1
Columns 1 to 32
576 panels · 51% of port
Power runs 11 circuits · up to 54 panels/circuit · 23.8 kW max · 1× distro
Circuit 1
Columns 1 to 3, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L1
Circuit 2
Columns 4 to 6, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L2
Circuit 3
Columns 7 to 9, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L3
Circuit 4
Columns 10 to 12, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L1
Circuit 5
Columns 13 to 15, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L2
Circuit 6
Columns 16 to 18, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L3
Circuit 7
Columns 19 to 21, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L1
Circuit 8
Columns 22 to 24, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L2
Circuit 9
Columns 25 to 27, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L3
Circuit 10
Columns 28 to 30, snake up and down, hops right
54 panels · 2,230.2 W · 76% · Distro 1 · L1
Circuit 11
Columns 31 to 32, snake up and down, hops right
36 panels · 1,486.8 W · 51% · Distro 1 · L2
Patch
Distro 1: circuits 1 to 11 (L1×4 L2×4 L3×3)
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
✓ confirmedWall-mounted: the wall or structure carries the panels, 1,342 kg over 8.00 × 4.50 m, about 37 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
✓ confirmedCircuits sized on max load (full white) at 80% derate: 71 panels per 16 A / 230 V circuit (41.3 W/panel). Typical draw shown separately for the venue/generator ask.
✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 3 columns need 11 circuits (single columns would need 32, full rows 18).
openPower for a permanent install comes as 11 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 902 panels per run, giving 1 runs, each looped back to a B port on a second unit, worst run 51%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
openHome runs cut at run distance + wall height + 5 m service loop.
openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 1153 tags · 1 data runs · 11 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
site-specific, not derived; carries 1,342 kg, about 37 kg/m²
Power 0/2 done
11 pcs
House circuits (16 A / 230 V)
23.8 kW max · ~7.1 kW typical content · from the building's board
622 pcs
TRUE1 jumpers
panel-to-panel, incl. 10% spare
Data & control 0/3 done
2 pcs
NovaStar VX1000
2/20 ports used (A and B, 1 + 1 units)
2 pcs
Cat6A home runs, ~40 m
run + height + 5 m loop, A and B
634 pcs
Cat6 panel jumpers
incl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app