Absen KLCOB0.7 V2 · 0.78 mm

This sheet gives the datasheet figures for the Absen KLCOB0.7 V2, a 0.78 mm LED panel in a 600 × 337.5 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerAbsen, KLCOB V2 series
Pixel pitch0.78 mm
Cabinet size600 × 337.5 × 39.3 mm
Pixels per cabinet768 × 432 (331,776 px)
Weight4.6 kg (23 kg/m²)
Max power, full white91 W (449 W/m²)
Typical power30 W
Refresh rate3,840 Hz
Brightness800 nits
Viewing angle (H / V)160° / 160°
Max hang15 panels
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Absen: KLCOB V2 / KLCOB Pro V2 series specifications (2026-04-11), retrieved 2026-09-17. Fixed-install flip-chip COB panel, front service for modules and power supplies, IP40 front and IP21 rear. Sheet gives 450/150 W/m² maximum and average (power tolerance ±15% by the sheet) and heat 1,536/512 BTU/h/m²; the rigging limit of 15 is the sheet’s own.

Worked example: a 13 × 13 wall (16:9)

13 columns by 13 rows of this tile makes a 7.80 × 4.39 m wall, the closest this cabinet gets to 16:9, at 9,984 × 5,616 pixels (56.07 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 942 kg including bumpers, around 377 kg across each of 3 points.

On European power it draws 15.4 kW at full white (5.1 kW on typical content), which at an 80% derate is 7 × 16 A / 230 V circuits. Data comes to 169 runs at up to 1 panels per port, worst run 51% loaded, fitting 17 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R151%R251%R351%R451%R551%R651%R751%R851%R951%R1051%R1151%R1251%R1351%R1451%R1551%R1651%R1751%R1851%R1951%R2051%R2151%R2251%R2351%R2451%R2551%R2651%R2751%R2851%R2951%R3051%R3151%R3251%R3351%R3451%R3551%R3651%R3751%R3851%R3951%R4051%R4151%R4251%R4351%R4451%R4551%R4651%R4751%R4851%R4951%R5051%R5151%R5251%R5351%R5451%R5551%R5651%R5751%R5851%R5951%R6051%R6151%R6251%R6351%R6451%R6551%R6651%R6751%R6851%R6951%R7051%R7151%R7251%R7351%R7451%R7551%R7651%R7751%R7851%R7951%R8051%R8151%R8251%R8351%R8451%R8551%R8651%R8751%R8851%R8951%R9051%R9151%R9251%R9351%R9451%R9551%R9651%R9751%R9851%R9951%R10051%R10151%R10251%R10351%R10451%R10551%R10651%R10751%R10851%R10951%R11051%R11151%R11251%R11351%R11451%R11551%R11651%R11751%R11851%R11951%R12051%R12151%R12251%R12351%R12451%R12551%R12651%R12751%R12851%R12951%R13051%R13151%R13251%R13351%R13451%R13551%R13651%R13751%R13851%R13951%R14051%R14151%R14251%R14351%R14451%R14551%R14651%R14751%R14851%R14951%R15051%R15151%R15251%R15351%R15451%R15551%R15651%R15751%R15851%R15951%R16051%R16151%R16251%R16351%R16451%R16551%R16651%R16751%R16851%R16951%2w2w2w2w2w2w1w~377 kg~377 kg~377 kg7.80 m (9,984 px)4.39 m (5,616 px)15.4 kW max · 7× 16 A / 230 V · 169 runs on 17× NovaStar VX1000

Main: 13 × 13 Absen KLCOB0.7 V2

Size
7.80 × 4.39 m
Diagonal
352 in
Area
34.2 m²
Resolution
9,984 × 5,616 px
Pixels
56.07 M px
Panels
169 + 9 spares
Weight
942 kg incl. bumpers
Power
15.4 kW max, 5.1 kW typical, 7 circuits
Data
169 runs on 17 processors at 60 Hz 8-bit
Truck
10.8 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainAbsen KLCOB0.7 V213 × 137.80 × 4.39 m · 352 in9,984 × 5,616 pxflown
Panels
169 + 9 spares
Weight
942 kg incl. bumpers
Power
15.4 kW max, 5.1 kW typical, 7 circuits
Data
169 runs on 17 processors at 60 Hz 8-bit
Truck
10.8 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 169 runs · up to 1 panels per run at 80% · worst 51% · 17× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 11 panels · 51% of port
Run 2Column 1, rows 2 to 21 panels · 51% of port
Run 3Column 1, rows 3 to 31 panels · 51% of port
Run 4Column 1, rows 4 to 41 panels · 51% of port
Run 5Column 1, rows 5 to 51 panels · 51% of port
Run 6Column 1, rows 6 to 61 panels · 51% of port
Run 7Column 1, rows 7 to 71 panels · 51% of port
Run 8Column 1, rows 8 to 81 panels · 51% of port
Run 9Column 1, rows 9 to 91 panels · 51% of port
Run 10Column 1, rows 10 to 101 panels · 51% of port
Run 11Column 1, rows 11 to 111 panels · 51% of port
Run 12Column 1, rows 12 to 121 panels · 51% of port
Run 13Column 1, rows 13 to 131 panels · 51% of port
Run 14Column 2, rows 1 to 11 panels · 51% of port
Run 15Column 2, rows 2 to 21 panels · 51% of port
Run 16Column 2, rows 3 to 31 panels · 51% of port
Run 17Column 2, rows 4 to 41 panels · 51% of port
Run 18Column 2, rows 5 to 51 panels · 51% of port
Run 19Column 2, rows 6 to 61 panels · 51% of port
Run 20Column 2, rows 7 to 71 panels · 51% of port
Run 21Column 2, rows 8 to 81 panels · 51% of port
Run 22Column 2, rows 9 to 91 panels · 51% of port
Run 23Column 2, rows 10 to 101 panels · 51% of port
Run 24Column 2, rows 11 to 111 panels · 51% of port
Run 25Column 2, rows 12 to 121 panels · 51% of port
Run 26Column 2, rows 13 to 131 panels · 51% of port
Run 27Column 3, rows 1 to 11 panels · 51% of port
Run 28Column 3, rows 2 to 21 panels · 51% of port
Run 29Column 3, rows 3 to 31 panels · 51% of port
Run 30Column 3, rows 4 to 41 panels · 51% of port
Run 31Column 3, rows 5 to 51 panels · 51% of port
Run 32Column 3, rows 6 to 61 panels · 51% of port
Run 33Column 3, rows 7 to 71 panels · 51% of port
Run 34Column 3, rows 8 to 81 panels · 51% of port
Run 35Column 3, rows 9 to 91 panels · 51% of port
Run 36Column 3, rows 10 to 101 panels · 51% of port
Run 37Column 3, rows 11 to 111 panels · 51% of port
Run 38Column 3, rows 12 to 121 panels · 51% of port
Run 39Column 3, rows 13 to 131 panels · 51% of port
Run 40Column 4, rows 1 to 11 panels · 51% of port
Run 41Column 4, rows 2 to 21 panels · 51% of port
Run 42Column 4, rows 3 to 31 panels · 51% of port
Run 43Column 4, rows 4 to 41 panels · 51% of port
Run 44Column 4, rows 5 to 51 panels · 51% of port
Run 45Column 4, rows 6 to 61 panels · 51% of port
Run 46Column 4, rows 7 to 71 panels · 51% of port
Run 47Column 4, rows 8 to 81 panels · 51% of port
Run 48Column 4, rows 9 to 91 panels · 51% of port
Run 49Column 4, rows 10 to 101 panels · 51% of port
Run 50Column 4, rows 11 to 111 panels · 51% of port
Run 51Column 4, rows 12 to 121 panels · 51% of port
Run 52Column 4, rows 13 to 131 panels · 51% of port
Run 53Column 5, rows 1 to 11 panels · 51% of port
Run 54Column 5, rows 2 to 21 panels · 51% of port
Run 55Column 5, rows 3 to 31 panels · 51% of port
Run 56Column 5, rows 4 to 41 panels · 51% of port
Run 57Column 5, rows 5 to 51 panels · 51% of port
Run 58Column 5, rows 6 to 61 panels · 51% of port
Run 59Column 5, rows 7 to 71 panels · 51% of port
Run 60Column 5, rows 8 to 81 panels · 51% of port
Run 61Column 5, rows 9 to 91 panels · 51% of port
Run 62Column 5, rows 10 to 101 panels · 51% of port
Run 63Column 5, rows 11 to 111 panels · 51% of port
Run 64Column 5, rows 12 to 121 panels · 51% of port
Run 65Column 5, rows 13 to 131 panels · 51% of port
Run 66Column 6, rows 1 to 11 panels · 51% of port
Run 67Column 6, rows 2 to 21 panels · 51% of port
Run 68Column 6, rows 3 to 31 panels · 51% of port
Run 69Column 6, rows 4 to 41 panels · 51% of port
Run 70Column 6, rows 5 to 51 panels · 51% of port
Run 71Column 6, rows 6 to 61 panels · 51% of port
Run 72Column 6, rows 7 to 71 panels · 51% of port
Run 73Column 6, rows 8 to 81 panels · 51% of port
Run 74Column 6, rows 9 to 91 panels · 51% of port
Run 75Column 6, rows 10 to 101 panels · 51% of port
Run 76Column 6, rows 11 to 111 panels · 51% of port
Run 77Column 6, rows 12 to 121 panels · 51% of port
Run 78Column 6, rows 13 to 131 panels · 51% of port
Run 79Column 7, rows 1 to 11 panels · 51% of port
Run 80Column 7, rows 2 to 21 panels · 51% of port
Run 81Column 7, rows 3 to 31 panels · 51% of port
Run 82Column 7, rows 4 to 41 panels · 51% of port
Run 83Column 7, rows 5 to 51 panels · 51% of port
Run 84Column 7, rows 6 to 61 panels · 51% of port
Run 85Column 7, rows 7 to 71 panels · 51% of port
Run 86Column 7, rows 8 to 81 panels · 51% of port
Run 87Column 7, rows 9 to 91 panels · 51% of port
Run 88Column 7, rows 10 to 101 panels · 51% of port
Run 89Column 7, rows 11 to 111 panels · 51% of port
Run 90Column 7, rows 12 to 121 panels · 51% of port
Run 91Column 7, rows 13 to 131 panels · 51% of port
Run 92Column 8, rows 1 to 11 panels · 51% of port
Run 93Column 8, rows 2 to 21 panels · 51% of port
Run 94Column 8, rows 3 to 31 panels · 51% of port
Run 95Column 8, rows 4 to 41 panels · 51% of port
Run 96Column 8, rows 5 to 51 panels · 51% of port
Run 97Column 8, rows 6 to 61 panels · 51% of port
Run 98Column 8, rows 7 to 71 panels · 51% of port
Run 99Column 8, rows 8 to 81 panels · 51% of port
Run 100Column 8, rows 9 to 91 panels · 51% of port
Run 101Column 8, rows 10 to 101 panels · 51% of port
Run 102Column 8, rows 11 to 111 panels · 51% of port
Run 103Column 8, rows 12 to 121 panels · 51% of port
Run 104Column 8, rows 13 to 131 panels · 51% of port
Run 105Column 9, rows 1 to 11 panels · 51% of port
Run 106Column 9, rows 2 to 21 panels · 51% of port
Run 107Column 9, rows 3 to 31 panels · 51% of port
Run 108Column 9, rows 4 to 41 panels · 51% of port
Run 109Column 9, rows 5 to 51 panels · 51% of port
Run 110Column 9, rows 6 to 61 panels · 51% of port
Run 111Column 9, rows 7 to 71 panels · 51% of port
Run 112Column 9, rows 8 to 81 panels · 51% of port
Run 113Column 9, rows 9 to 91 panels · 51% of port
Run 114Column 9, rows 10 to 101 panels · 51% of port
Run 115Column 9, rows 11 to 111 panels · 51% of port
Run 116Column 9, rows 12 to 121 panels · 51% of port
Run 117Column 9, rows 13 to 131 panels · 51% of port
Run 118Column 10, rows 1 to 11 panels · 51% of port
Run 119Column 10, rows 2 to 21 panels · 51% of port
Run 120Column 10, rows 3 to 31 panels · 51% of port
Run 121Column 10, rows 4 to 41 panels · 51% of port
Run 122Column 10, rows 5 to 51 panels · 51% of port
Run 123Column 10, rows 6 to 61 panels · 51% of port
Run 124Column 10, rows 7 to 71 panels · 51% of port
Run 125Column 10, rows 8 to 81 panels · 51% of port
Run 126Column 10, rows 9 to 91 panels · 51% of port
Run 127Column 10, rows 10 to 101 panels · 51% of port
Run 128Column 10, rows 11 to 111 panels · 51% of port
Run 129Column 10, rows 12 to 121 panels · 51% of port
Run 130Column 10, rows 13 to 131 panels · 51% of port
Run 131Column 11, rows 1 to 11 panels · 51% of port
Run 132Column 11, rows 2 to 21 panels · 51% of port
Run 133Column 11, rows 3 to 31 panels · 51% of port
Run 134Column 11, rows 4 to 41 panels · 51% of port
Run 135Column 11, rows 5 to 51 panels · 51% of port
Run 136Column 11, rows 6 to 61 panels · 51% of port
Run 137Column 11, rows 7 to 71 panels · 51% of port
Run 138Column 11, rows 8 to 81 panels · 51% of port
Run 139Column 11, rows 9 to 91 panels · 51% of port
Run 140Column 11, rows 10 to 101 panels · 51% of port
Run 141Column 11, rows 11 to 111 panels · 51% of port
Run 142Column 11, rows 12 to 121 panels · 51% of port
Run 143Column 11, rows 13 to 131 panels · 51% of port
Run 144Column 12, rows 1 to 11 panels · 51% of port
Run 145Column 12, rows 2 to 21 panels · 51% of port
Run 146Column 12, rows 3 to 31 panels · 51% of port
Run 147Column 12, rows 4 to 41 panels · 51% of port
Run 148Column 12, rows 5 to 51 panels · 51% of port
Run 149Column 12, rows 6 to 61 panels · 51% of port
Run 150Column 12, rows 7 to 71 panels · 51% of port
Run 151Column 12, rows 8 to 81 panels · 51% of port
Run 152Column 12, rows 9 to 91 panels · 51% of port
Run 153Column 12, rows 10 to 101 panels · 51% of port
Run 154Column 12, rows 11 to 111 panels · 51% of port
Run 155Column 12, rows 12 to 121 panels · 51% of port
Run 156Column 12, rows 13 to 131 panels · 51% of port
Run 157Column 13, rows 1 to 11 panels · 51% of port
Run 158Column 13, rows 2 to 21 panels · 51% of port
Run 159Column 13, rows 3 to 31 panels · 51% of port
Run 160Column 13, rows 4 to 41 panels · 51% of port
Run 161Column 13, rows 5 to 51 panels · 51% of port
Run 162Column 13, rows 6 to 61 panels · 51% of port
Run 163Column 13, rows 7 to 71 panels · 51% of port
Run 164Column 13, rows 8 to 81 panels · 51% of port
Run 165Column 13, rows 9 to 91 panels · 51% of port
Run 166Column 13, rows 10 to 101 panels · 51% of port
Run 167Column 13, rows 11 to 111 panels · 51% of port
Run 168Column 13, rows 12 to 121 panels · 51% of port
Run 169Column 13, rows 13 to 131 panels · 51% of port

Power runs 7 circuits · up to 26 panels/circuit · 15.4 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right26 panels · 2,366 W · 80% · Distro 1 · L3
Circuit 7Column 1313 panels · 1,183 W · 40% · Distro 1 · L1
PatchDistro 1: circuits 1 to 7 (L1×3 L2×2 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 32 panels per 16 A / 230 V circuit (91 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 7 circuits (single columns would need 13, full rows 13).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 1 panels per run, giving 169 runs, worst run 51%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 338 tags · 169 data runs · 7 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

169 pcsAbsen KLCOB0.7 V2 tiles13×13 wall, 7.8×4.4 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
1 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~377 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro15.4 kW max · ~5.1 kW typical content
7 pcsFeeder lines to wall (16 A / 230 V)~30 m each
179 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

17 pcsNovaStar VX1000169/170 ports used
169 pcsCat6A home runs, ~39 mrun + height + 5 m loop
186 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

23 pcsPanel dollies8 tiles per dolly
1 pcsBumper cases8 per case
10 pcsCable trunks~541 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
10.8 mTruck deck, linear52 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app