This sheet gives the datasheet figures for the Unilumin UpanelS 2.5, a 2.54 mm LED panel in a 609.92 × 343.08 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerUnilumin, UpanelS series
Pixel pitch2.54 mm
Cabinet size609.92 × 343.08 × 71 mm
Pixels per cabinet240 × 135 (32,400 px)
Weight7.5 kg (36 kg/m²)
Max power, full white80 W (382 W/m²)
Typical power26 W
Refresh rate3,840 Hz
Brightness600 nits
Viewing angle (H / V)160° / 160°
Optical figuressheet gives refresh as 1,920 to 3,840 Hz
Max hang20 panels
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Unilumin USA: UpanelS 2.5 specifications sheet, retrieved 2026-09-01. Fixed-install 16:9 cabinet.

Worked example: a 13 × 13 wall (16:9)

13 columns by 13 rows of this tile makes a 7.93 × 4.46 m wall, the closest this cabinet gets to 16:9, at 3,120 × 1,755 pixels (5.48 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 1,433 kg including bumpers, around 573 kg across each of 3 points.

On European power it draws 13.5 kW at full white (4.4 kW on typical content), which at an 80% derate is 7 × 16 A / 230 V circuits. Data comes to 13 runs at up to 16 panels per port, worst run 65% loaded, fitting 2 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R165%R265%R365%R465%R565%R665%R765%R865%R965%R1065%R1165%R1265%R1365%2w2w2w2w2w2w1w~573 kg~573 kg~573 kg7.93 m (3,120 px)4.46 m (1,755 px)13.5 kW max · 7× 16 A / 230 V · 13 runs on 2× NovaStar VX1000

Main: 13 × 13 Unilumin UpanelS 2.5

Size
7.93 × 4.46 m
Area
35.4 m²
Resolution
3,120 × 1,755 px
Pixels
5.48 M px
Panels
169 + 9 spares
Weight
1,433 kg incl. bumpers
Power
13.5 kW max, 4.4 kW typical, 7 circuits
Data
13 runs on 2 processors at 60 Hz 8-bit
Truck
7.1 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainUnilumin UpanelS 2.513 × 137.93 × 4.46 m3,120 × 1,755 pxflown
Panels
169 + 9 spares
Weight
1,433 kg incl. bumpers
Power
13.5 kW max, 4.4 kW typical, 7 circuits
Data
13 runs on 2 processors at 60 Hz 8-bit
Truck
7.1 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 13 runs · up to 16 panels per run at 80% · worst 65% · 2× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 113 panels · 65% of port
Run 2Column 213 panels · 65% of port
Run 3Column 313 panels · 65% of port
Run 4Column 413 panels · 65% of port
Run 5Column 513 panels · 65% of port
Run 6Column 613 panels · 65% of port
Run 7Column 713 panels · 65% of port
Run 8Column 813 panels · 65% of port
Run 9Column 913 panels · 65% of port
Run 10Column 1013 panels · 65% of port
Run 11Column 1113 panels · 65% of port
Run 12Column 1213 panels · 65% of port
Run 13Column 1313 panels · 65% of port

Power runs 7 circuits · up to 26 panels/circuit · 13.5 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right26 panels · 2,080 W · 71% · Distro 1 · L3
Circuit 7Column 1313 panels · 1,040 W · 35% · Distro 1 · L1
PatchDistro 1: circuits 1 to 7 (L1×3 L2×2 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 36 panels per 16 A / 230 V circuit (80 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 7 circuits (single columns would need 13, full rows 13).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 16 panels per run, giving 13 runs, worst run 65%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 338 tags · 13 data runs · 7 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

169 pcsUnilumin UpanelS 2.5 tiles13×13 wall, 7.9×4.5 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
1 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~573 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro13.5 kW max · ~4.4 kW typical content
7 pcsFeeder lines to wall (16 A / 230 V)~30 m each
179 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

2 pcsNovaStar VX100013/20 ports used
13 pcsCat6A home runs, ~39 mrun + height + 5 m loop
186 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

23 pcsPanel dollies8 tiles per dolly
1 pcsBumper cases8 per case
7 pcsCable trunks~385 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
7.1 mTruck deck, linear34 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Unilumin panels

The UpanelS series has 10 panels: the Unilumin UpanelS series compared.

Where this panel sits

This sheet is listed under Unilumin LED panels, the 2.5 to 2.6 mm pixel pitch class, fixed-install LED panels, rental and touring LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.