This sheet gives the datasheet figures for the Sharp LD-FE123, a 1.2 mm LED panel in a 608 × 342 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSharp, FE Series series
Pixel pitch1.2 mm
Cabinet size608 × 342 × 49 mm
Pixels per cabinet480 × 270 (129,600 px)
Weight8.8 kg (42 kg/m²)
Max power, full white38 W (183 W/m²)
Typical power22 W
Refresh rate3,840 Hz
Brightness700 nits
Viewing angle (H / V)170° / 160°
Optical figuressheet gives refresh as ≤3,840 Hz
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Sharp: LD-FE123 datasheet, retrieved 2026-09-02. Wall-mounted install module (front service), not a rental hanging system: Sharp publishes no flown limit, so the hang figure is a conservative placeholder. Datasheet power 183/106 W/m² (38/22 W per module). Headline pitch is 1.2 mm; the sheet’s own geometry (608 mm ÷ 480 px) gives 1.27 mm. Also sold as 110″ FullHD and 220″ UHD bundles.

Worked example: a 13 × 13 wall (16:9)

13 columns by 13 rows of this tile makes a 7.90 × 4.45 m wall, the closest this cabinet gets to 16:9, at 6,240 × 3,510 pixels (21.90 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 1,487 kg, carried by the structure it is mounted on.

On European power it draws 6.4 kW at full white (3.7 kW on typical content), which at an 80% derate is 3 × 16 A / 230 V circuits. Data comes to 52 runs at up to 4 panels per port, worst run 80% loaded, fitting 12 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R180%R260%R360%R460%R580%R660%R760%R860%R980%R1060%R1160%R1260%R1380%R1460%R1560%R1660%R1780%R1860%R1960%R2060%R2180%R2260%R2360%R2460%R2580%R2660%R2760%R2860%R2980%R3060%R3160%R3260%R3380%R3460%R3560%R3660%R3780%R3860%R3960%R4060%R4180%R4260%R4360%R4460%R4580%R4660%R4760%R4860%R4980%R5060%R5160%R5260%wall-mounted: the structure carries 1,487 kg7.90 m (6,240 px)4.45 m (3,510 px)6.4 kW max · 3× 16 A / 230 V · 52 runs on 12× NovaStar VX1000

Main: 13 × 13 Sharp LD-FE123

Size
7.90 × 4.45 m
Area
35.1 m²
Resolution
6,240 × 3,510 px
Pixels
21.90 M px
Panels
169 + 9 spares
Weight
1,487 kg panels only
Power
6.4 kW max, 3.7 kW typical, 3 circuits
Data
52 runs on 12 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSharp LD-FE12313 × 137.90 × 4.45 m6,240 × 3,510 pxwall-mounted
Panels
169 + 9 spares
Weight
1,487 kg panels only
Power
6.4 kW max, 3.7 kW typical, 3 circuits
Data
52 runs on 12 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 52 runs · up to 4 panels per run at 80% · worst 80% · 12× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 44 panels · 80% of port
Run 2Column 1, rows 5 to 73 panels · 60% of port
Run 3Column 1, rows 8 to 103 panels · 60% of port
Run 4Column 1, rows 11 to 133 panels · 60% of port
Run 5Column 2, rows 1 to 44 panels · 80% of port
Run 6Column 2, rows 5 to 73 panels · 60% of port
Run 7Column 2, rows 8 to 103 panels · 60% of port
Run 8Column 2, rows 11 to 133 panels · 60% of port
Run 9Column 3, rows 1 to 44 panels · 80% of port
Run 10Column 3, rows 5 to 73 panels · 60% of port
Run 11Column 3, rows 8 to 103 panels · 60% of port
Run 12Column 3, rows 11 to 133 panels · 60% of port
Run 13Column 4, rows 1 to 44 panels · 80% of port
Run 14Column 4, rows 5 to 73 panels · 60% of port
Run 15Column 4, rows 8 to 103 panels · 60% of port
Run 16Column 4, rows 11 to 133 panels · 60% of port
Run 17Column 5, rows 1 to 44 panels · 80% of port
Run 18Column 5, rows 5 to 73 panels · 60% of port
Run 19Column 5, rows 8 to 103 panels · 60% of port
Run 20Column 5, rows 11 to 133 panels · 60% of port
Run 21Column 6, rows 1 to 44 panels · 80% of port
Run 22Column 6, rows 5 to 73 panels · 60% of port
Run 23Column 6, rows 8 to 103 panels · 60% of port
Run 24Column 6, rows 11 to 133 panels · 60% of port
Run 25Column 7, rows 1 to 44 panels · 80% of port
Run 26Column 7, rows 5 to 73 panels · 60% of port
Run 27Column 7, rows 8 to 103 panels · 60% of port
Run 28Column 7, rows 11 to 133 panels · 60% of port
Run 29Column 8, rows 1 to 44 panels · 80% of port
Run 30Column 8, rows 5 to 73 panels · 60% of port
Run 31Column 8, rows 8 to 103 panels · 60% of port
Run 32Column 8, rows 11 to 133 panels · 60% of port
Run 33Column 9, rows 1 to 44 panels · 80% of port
Run 34Column 9, rows 5 to 73 panels · 60% of port
Run 35Column 9, rows 8 to 103 panels · 60% of port
Run 36Column 9, rows 11 to 133 panels · 60% of port
Run 37Column 10, rows 1 to 44 panels · 80% of port
Run 38Column 10, rows 5 to 73 panels · 60% of port
Run 39Column 10, rows 8 to 103 panels · 60% of port
Run 40Column 10, rows 11 to 133 panels · 60% of port
Run 41Column 11, rows 1 to 44 panels · 80% of port
Run 42Column 11, rows 5 to 73 panels · 60% of port
Run 43Column 11, rows 8 to 103 panels · 60% of port
Run 44Column 11, rows 11 to 133 panels · 60% of port
Run 45Column 12, rows 1 to 44 panels · 80% of port
Run 46Column 12, rows 5 to 73 panels · 60% of port
Run 47Column 12, rows 8 to 103 panels · 60% of port
Run 48Column 12, rows 11 to 133 panels · 60% of port
Run 49Column 13, rows 1 to 44 panels · 80% of port
Run 50Column 13, rows 5 to 73 panels · 60% of port
Run 51Column 13, rows 8 to 103 panels · 60% of port
Run 52Column 13, rows 11 to 133 panels · 60% of port

Power runs 3 circuits · up to 65 panels/circuit · 6.4 kW max · 1× distro

Circuit 1Columns 1 to 5, snake up and down, hops right65 panels · 2,470 W · 84% · Distro 1 · L1
Circuit 2Columns 6 to 9, snake up and down, hops right52 panels · 1,976 W · 67% · Distro 1 · L2
Circuit 3Columns 10 to 13, snake up and down, hops right52 panels · 1,976 W · 67% · Distro 1 · L3
PatchDistro 1: circuits 1 to 3 (L1×1 L2×1 L3×1)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,487 kg over 7.90 × 4.45 m, about 42 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 77 panels per 16 A / 230 V circuit (38 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 5 columns need 3 circuits (single columns would need 13, full rows 13).
  5. openPower for a permanent install comes as 3 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 4 panels per run, giving 52 runs, each looped back to a B port on a second unit, worst run 80%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 390 tags · 52 data runs · 3 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

169 pcsSharp LD-FE123 tiles13×13 wall, 7.9×4.4 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,487 kg, about 42 kg/m²

Power 0/2 done

3 pcsHouse circuits (16 A / 230 V)6.4 kW max · ~3.7 kW typical content · from the building's board
183 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

12 pcsNovaStar VX1000104/120 ports used (A and B, 6 + 6 units)
104 pcsCat6A home runs, ~39 mrun + height + 5 m loop, A and B
186 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Sharp panels

The FE Series series has 4 panels: the Sharp FE Series series compared.

Where this panel sits

This sheet is listed under Sharp LED panels, the 1.2 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.