Barco X1.9 · 1.92 mm

This sheet gives the datasheet figures for the Barco X1.9, a 1.92 mm LED panel in a 400 × 450 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerBarco, X series
Pixel pitch1.92 mm
Cabinet size400 × 450 × 91 mm
Pixels per cabinet208 × 234 (48,672 px)
Weight6.6 kg (37 kg/m²)
Max power, full white165 W (917 W/m²)
Typical power55 W (estimated; not published)
Refresh ratenot published
Brightness1,000 nits
Viewing angle (H / V)120° / 120°
Optical figuresrefresh rate not on the X1.9 sheet; viewing angle given as ±60°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Barco: X1.9 spec sheet, retrieved 2026-09-02. Indoor install tile in an unusual 400×450 format, 1,000 nits, front/back service, full data redundancy. Spec sheet gives 917 W/m² max (165 W per tile) and no typical figure, so the average shown is max ÷ 3. No hang limit published, so the hang figure is a conservative placeholder.

Worked example: a 20 × 10 wall (16:9)

20 columns by 10 rows of this tile makes a 8.00 × 4.50 m wall, the closest this cabinet gets to 16:9, at 4,160 × 2,340 pixels (9.73 MP): 200 panels plus 10 spares at the one-off rate. It weighs about 1,320 kg, carried by the structure it is mounted on.

On European power it draws 33 kW at full white (11 kW on typical content), which at an 80% derate is 20 × 16 A / 230 V circuits. Data comes to 20 runs at up to 10 panels per port, worst run 75% loaded, fitting 4 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R175%R275%R375%R475%R575%R675%R775%R875%R975%R1075%R1175%R1275%R1375%R1475%R1575%R1675%R1775%R1875%R1975%R2075%wall-mounted: the structure carries 1,320 kg8.00 m (4,160 px)4.50 m (2,340 px)33 kW max · 20× 16 A / 230 V · 20 runs on 4× NovaStar VX1000

Main: 20 × 10 Barco X1.9

Size
8.00 × 4.50 m
Area
36.0 m²
Resolution
4,160 × 2,340 px
Pixels
9.73 M px
Panels
200 + 10 spares
Weight
1,320 kg panels only
Power
33 kW max, 11 kW typical, 20 circuits
Data
20 runs on 4 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainBarco X1.920 × 108.00 × 4.50 m4,160 × 2,340 pxwall-mounted
Panels
200 + 10 spares
Weight
1,320 kg panels only
Power
33 kW max, 11 kW typical, 20 circuits
Data
20 runs on 4 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 20 runs · up to 10 panels per run at 80% · worst 75% · 4× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 110 panels · 75% of port
Run 2Column 210 panels · 75% of port
Run 3Column 310 panels · 75% of port
Run 4Column 410 panels · 75% of port
Run 5Column 510 panels · 75% of port
Run 6Column 610 panels · 75% of port
Run 7Column 710 panels · 75% of port
Run 8Column 810 panels · 75% of port
Run 9Column 910 panels · 75% of port
Run 10Column 1010 panels · 75% of port
Run 11Column 1110 panels · 75% of port
Run 12Column 1210 panels · 75% of port
Run 13Column 1310 panels · 75% of port
Run 14Column 1410 panels · 75% of port
Run 15Column 1510 panels · 75% of port
Run 16Column 1610 panels · 75% of port
Run 17Column 1710 panels · 75% of port
Run 18Column 1810 panels · 75% of port
Run 19Column 1910 panels · 75% of port
Run 20Column 2010 panels · 75% of port

Power runs 20 circuits · up to 10 panels/circuit · 33 kW max · 2× distro

Circuit 1Column 110 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 2Column 210 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 3Column 310 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 4Column 410 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 5Column 510 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 6Column 610 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 7Column 710 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 8Column 810 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 9Column 910 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 10Column 1010 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 11Column 1110 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 12Column 1210 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 13Column 1310 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 14Column 1410 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 15Column 1510 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 16Column 1610 panels · 1,650 W · 56% · Distro 1 · L1
Circuit 17Column 1710 panels · 1,650 W · 56% · Distro 1 · L2
Circuit 18Column 1810 panels · 1,650 W · 56% · Distro 1 · L3
Circuit 19Column 1910 panels · 1,650 W · 56% · Distro 2 · L1
Circuit 20Column 2010 panels · 1,650 W · 56% · Distro 2 · L2
PatchDistro 1: circuits 1 to 18 (L1×6 L2×6 L3×6) · Distro 2: circuits 19 to 20 (L1×1 L2×1 L3×0)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,320 kg over 8.00 × 4.50 m, about 37 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 17 panels per 16 A / 230 V circuit (165 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 20 circuits (full rows would need 20).
  5. openPower for a permanent install comes as 20 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 10 panels per run, giving 20 runs, each looped back to a B port on a second unit, worst run 75%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 420 tags · 20 data runs · 20 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

200 pcsBarco X1.9 tiles20×10 wall, 8.0×4.5 m
10 pcsSpare tilesone-off rate 5%
8 pcsSpare receiving cards
8 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,320 kg, about 37 kg/m²

Power 0/2 done

20 pcsHouse circuits (16 A / 230 V)33 kW max · ~11 kW typical content · from the building's board
199 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

4 pcsNovaStar VX100040/40 ports used (A and B, 2 + 2 units)
40 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
221 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app