Manufacturer specifications, a worked example wall, and a live calculator preloaded with this tile. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.
| Manufacturer | YES TECH — MT II series |
| Pixel pitch | 3.9 mm |
| Cabinet size | 500 × 500 × 83 mm |
| Pixels per cabinet | 128 × 64 (8,192 px) |
| Weight | 5.8 kg (23 kg/m²) |
| Max power, full white | 113 W (452 W/m²) |
| Typical power | 25 W |
| Max hang | not published by manufacturer |
| Panels per dolly | 8 (our packing assumption) |
Source: YES TECH — MT II series specifications — retrieved 2026-09-02. Outdoor mesh/creative cabinet, IP65, 4,000–4,500 nits. Anamorphic pitch: 3.9 mm horizontal, 7.8 mm vertical (128×64 px on a 500×500 cabinet). Spec table gives 450/100 W/m² ±15%. No hanging limit published — conservative placeholder.
16 columns by 9 rows of this tile makes a 8.00 × 4.50 m wall — the closest this cabinet gets to 16:9 — at 2,048 × 576 pixels (1.18 MP) — 144 panels plus 8 spares at the one-off rate. It weighs about 1,035 kg including bumpers, around 414 kg across each of 3 points.
On European power it draws 16.3 kW at full white (3.6 kW on typical content), which at an 80% derate is 8 × 16 A / 230 V circuits. Data comes to 3 runs at up to 63 panels per port, worst run 68% loaded, fitting 1 × Novastar VX1000. Every figure is derived by the calculator below — change the numbers for your own wall.
Job
Walls
Planning several walls on one job — main + IMAG + DJ riser, shared spares and one truck sum — is a Solo feature.
Datasheet PDF parsing — upload a sheet, get the form pre-filled — is a Solo feature. Manufacturers can always parse and submit sheets free on the vendors page.
Quick resolution · size + pitch
Rig stock · bumpers
| 144 pcs | ROE Black Pearl BP2 V2 tiles | 16×9 wall, 8.0×4.5 m | |
| 8 pcs | Spare tiles | one-off rate 5% | |
| 6 pcs | Spare receiving cards | ||
| 6 pcs | Spare PSUs |
| 8 pcs | 2-wide bumpers | from your stock | |
| 3 pcs | Chain hoists, 1 t | point load ~619 kg incl. 1.2 dyn. | |
| 6 pcs | Steels, 1 m | 2 per point | |
| 6 pcs | Spansets | 2 per point | |
| 12 pcs | Shackles, 3.25 t | 4 per point | |
| 9 m | Truss to span wall | +1 m overhang — or house points |
| 1 pcs | 63 A 3-phase distro | 23 kW max · ~11.5 kW typical content | |
| 8 pcs | Feeder lines to wall (16 A / 230 V) | ~30 m each | |
| 150 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
| 2 pcs | Novastar VX1000 | 16/20 ports used | |
| 16 pcs | Cat6A home runs, ~40 m | run + height + 5 m loop | |
| 159 pcs | Cat6 panel jumpers | incl. 10% spare |
| 19 pcs | Panel dollies | 8 tiles per dolly | |
| 1 pcs | Bumper cases | 8 per case | |
| 6 pcs | Cable trunks | ~333 cables total | |
| 1 pcs | Rigging trunks | ||
| 1 set | Gaff, velcro, zip ties, sharpies | always | |
| 6 m | Truck deck, linear | 29 cases est. |
| Run 1 | Column 1 | 9 panels · 43% of port |
| Run 2 | Column 2 | 9 panels · 43% of port |
| Run 3 | Column 3 | 9 panels · 43% of port |
| Run 4 | Column 4 | 9 panels · 43% of port |
| Run 5 | Column 5 | 9 panels · 43% of port |
| Run 6 | Column 6 | 9 panels · 43% of port |
| Run 7 | Column 7 | 9 panels · 43% of port |
| Run 8 | Column 8 | 9 panels · 43% of port |
| Run 9 | Column 9 | 9 panels · 43% of port |
| Run 10 | Column 10 | 9 panels · 43% of port |
| Run 11 | Column 11 | 9 panels · 43% of port |
| Run 12 | Column 12 | 9 panels · 43% of port |
| Run 13 | Column 13 | 9 panels · 43% of port |
| Run 14 | Column 14 | 9 panels · 43% of port |
| Run 15 | Column 15 | 9 panels · 43% of port |
| Run 16 | Column 16 | 9 panels · 43% of port |
| Circuit 1 | Columns 1–2 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 2 | Columns 3–4 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Circuit 3 | Columns 5–6 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L3 |
| Circuit 4 | Columns 7–8 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 5 | Columns 9–10 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Circuit 6 | Columns 11–12 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L3 |
| Circuit 7 | Columns 13–14 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 8 | Columns 15–16 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Patch | Distro 1: circuits 1–8 (L1×3 L2×3 L3×2) | |
Every quantity above is derived from the rules below — written with working AV techs and corrected as they red-pen them. Panel and processor specs are placeholders until verified against manufacturer data.
2,048 × 576 pixels — 1.18 megapixels across 8.00 × 4.50 metres.
About 16.3 kW at full white and roughly 3.6 kW on typical content, from a published 113 W maximum per cabinet. Sized on maximum at an 80% derate that is 8 × 16 A / 230 V circuits.
63 at 60 Hz 8-bit with ports loaded to 80%, since each cabinet is 8,192 pixels. That gives 3 runs for this wall; redundant looping would double it.
5.8 kg per cabinet, or about 23 kg per square metre. The example wall totals roughly 1,035 kg including bumpers, around 414 kg per point across 3 points. Point loads must be verified by a competent rigger.
How these numbers are derived: power and circuits, panels per data port, the pack list.