Main: 13 × 13 Sharp LD-EC121
- Size
- 7.80 × 4.39 m
- Area
- 34.2 m²
- Resolution
- 6,240 × 3,510 px
- Pixels
- 21.90 M px
- Panels
- 169 + 9 spares
- Weight
- 727 kg panels only
- Power
- 8.6 kW max, 4.9 kW typical, 4 circuits
- Data
- 52 runs on 12 processors at 60 Hz 8-bit
This is a live example. Change the panel and the size in the steps and every figure recomputes.
| Main | Sharp LD-EC121 | 13 × 13 | 7.80 × 4.39 m | 6,240 × 3,510 px | wall-mounted |
- Panels
- 169 + 9 spares
- Weight
- 727 kg panels only
- Power
- 8.6 kW max, 4.9 kW typical, 4 circuits
- Data
- 52 runs on 12 processors at 60 Hz 8-bit
The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 52 runs · up to 4 panels per run at 80% · worst 80% · 12× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
| Run 1 | Column 1, rows 1 to 4 | 4 panels · 80% of port |
| Run 2 | Column 1, rows 5 to 7 | 3 panels · 60% of port |
| Run 3 | Column 1, rows 8 to 10 | 3 panels · 60% of port |
| Run 4 | Column 1, rows 11 to 13 | 3 panels · 60% of port |
| Run 5 | Column 2, rows 1 to 4 | 4 panels · 80% of port |
| Run 6 | Column 2, rows 5 to 7 | 3 panels · 60% of port |
| Run 7 | Column 2, rows 8 to 10 | 3 panels · 60% of port |
| Run 8 | Column 2, rows 11 to 13 | 3 panels · 60% of port |
| Run 9 | Column 3, rows 1 to 4 | 4 panels · 80% of port |
| Run 10 | Column 3, rows 5 to 7 | 3 panels · 60% of port |
| Run 11 | Column 3, rows 8 to 10 | 3 panels · 60% of port |
| Run 12 | Column 3, rows 11 to 13 | 3 panels · 60% of port |
| Run 13 | Column 4, rows 1 to 4 | 4 panels · 80% of port |
| Run 14 | Column 4, rows 5 to 7 | 3 panels · 60% of port |
| Run 15 | Column 4, rows 8 to 10 | 3 panels · 60% of port |
| Run 16 | Column 4, rows 11 to 13 | 3 panels · 60% of port |
| Run 17 | Column 5, rows 1 to 4 | 4 panels · 80% of port |
| Run 18 | Column 5, rows 5 to 7 | 3 panels · 60% of port |
| Run 19 | Column 5, rows 8 to 10 | 3 panels · 60% of port |
| Run 20 | Column 5, rows 11 to 13 | 3 panels · 60% of port |
| Run 21 | Column 6, rows 1 to 4 | 4 panels · 80% of port |
| Run 22 | Column 6, rows 5 to 7 | 3 panels · 60% of port |
| Run 23 | Column 6, rows 8 to 10 | 3 panels · 60% of port |
| Run 24 | Column 6, rows 11 to 13 | 3 panels · 60% of port |
| Run 25 | Column 7, rows 1 to 4 | 4 panels · 80% of port |
| Run 26 | Column 7, rows 5 to 7 | 3 panels · 60% of port |
| Run 27 | Column 7, rows 8 to 10 | 3 panels · 60% of port |
| Run 28 | Column 7, rows 11 to 13 | 3 panels · 60% of port |
| Run 29 | Column 8, rows 1 to 4 | 4 panels · 80% of port |
| Run 30 | Column 8, rows 5 to 7 | 3 panels · 60% of port |
| Run 31 | Column 8, rows 8 to 10 | 3 panels · 60% of port |
| Run 32 | Column 8, rows 11 to 13 | 3 panels · 60% of port |
| Run 33 | Column 9, rows 1 to 4 | 4 panels · 80% of port |
| Run 34 | Column 9, rows 5 to 7 | 3 panels · 60% of port |
| Run 35 | Column 9, rows 8 to 10 | 3 panels · 60% of port |
| Run 36 | Column 9, rows 11 to 13 | 3 panels · 60% of port |
| Run 37 | Column 10, rows 1 to 4 | 4 panels · 80% of port |
| Run 38 | Column 10, rows 5 to 7 | 3 panels · 60% of port |
| Run 39 | Column 10, rows 8 to 10 | 3 panels · 60% of port |
| Run 40 | Column 10, rows 11 to 13 | 3 panels · 60% of port |
| Run 41 | Column 11, rows 1 to 4 | 4 panels · 80% of port |
| Run 42 | Column 11, rows 5 to 7 | 3 panels · 60% of port |
| Run 43 | Column 11, rows 8 to 10 | 3 panels · 60% of port |
| Run 44 | Column 11, rows 11 to 13 | 3 panels · 60% of port |
| Run 45 | Column 12, rows 1 to 4 | 4 panels · 80% of port |
| Run 46 | Column 12, rows 5 to 7 | 3 panels · 60% of port |
| Run 47 | Column 12, rows 8 to 10 | 3 panels · 60% of port |
| Run 48 | Column 12, rows 11 to 13 | 3 panels · 60% of port |
| Run 49 | Column 13, rows 1 to 4 | 4 panels · 80% of port |
| Run 50 | Column 13, rows 5 to 7 | 3 panels · 60% of port |
| Run 51 | Column 13, rows 8 to 10 | 3 panels · 60% of port |
| Run 52 | Column 13, rows 11 to 13 | 3 panels · 60% of port |
Power runs 4 circuits · up to 52 panels/circuit · 8.6 kW max · 1× distro
| Circuit 1 | Columns 1 to 4, snake up and down, hops right | 52 panels · 2,652 W · 90% · Distro 1 · L1 |
| Circuit 2 | Columns 5 to 7, snake up and down, hops right | 39 panels · 1,989 W · 68% · Distro 1 · L2 |
| Circuit 3 | Columns 8 to 10, snake up and down, hops right | 39 panels · 1,989 W · 68% · Distro 1 · L3 |
| Circuit 4 | Columns 11 to 13, snake up and down, hops right | 39 panels · 1,989 W · 68% · Distro 1 · L1 |
| Patch | Distro 1: circuits 1 to 4 (L1×2 L2×1 L3×1) | |
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
- openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
- ✓ confirmedWall-mounted: the wall or structure carries the panels, 727 kg over 7.80 × 4.39 m, about 21 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
- ✓ confirmedCircuits sized on max load (full white) at 80% derate: 57 panels per 16 A / 230 V circuit (51 W/panel). Typical draw shown separately for the venue/generator ask.
- ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 4 columns need 4 circuits (single columns would need 13, full rows 13).
- openPower for a permanent install comes as 4 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
- ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
- ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 4 panels per run, giving 52 runs, each looped back to a B port on a second unit, worst run 80%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
- ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
- openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
- openHome runs cut at run distance + wall height + 5 m service loop.
- openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
- ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
- openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 390 tags · 52 data runs · 4 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Copy tags as CSV 🔒The tag list, your own label format, and the CSV for a label printer are a Solo feature.
Panels 0/4 done
| 169 pcs | Sharp LD-EC121 tiles | 13×13 wall, 7.8×4.4 m | ||
| 9 pcs | Spare tiles | one-off rate 5% | ||
| 7 pcs | Spare receiving cards | |||
| 7 pcs | Spare PSUs |
Rigging 0/1 done
| 1 set | Mounting structure | site-specific, not derived; carries 727 kg, about 21 kg/m² |
Power 0/2 done
| 4 pcs | House circuits (16 A / 230 V) | 8.6 kW max · ~4.9 kW typical content · from the building's board | ||
| 182 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
Data & control 0/3 done
| 12 pcs | NovaStar VX1000 | 104/120 ports used (A and B, 6 + 6 units) | ||
| 104 pcs | Cat6A home runs, ~39 m | run + height + 5 m loop, A and B | ||
| 186 pcs | Cat6 panel jumpers | incl. 10% spare |