Sharp LD-EC091 · 0.9 mm

This sheet gives the datasheet figures for the Sharp LD-EC091, a 0.9 mm LED panel in a 600 × 337.5 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSharp, EC Series (Essential) series
Pixel pitch0.9 mm
Cabinet size600 × 337.5 × 27.4 mm
Pixels per cabinet640 × 360 (230,400 px)
Weight4.3 kg (21 kg/m²)
Max power, full white63 W (311 W/m²)
Typical power42 W
Refresh rate3,840 Hz
Brightness600 nits
Viewing angle (H / V)160° / 140°
Optical figuressheet gives refresh as ≤3,840 Hz
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Sharp: LD-EC091 datasheet, retrieved 2026-09-02. Wall-mounted install module (front service), not a rental hanging system, so the hang figure is a conservative placeholder. Essential-line COB tile at 21 kg/m², the lightest Sharp module. Datasheet power 311/207 W/m² (63/42 W per module); the 108″ bundle total (1,008/672 W = 16×) confirms both. Headline pitch 0.9 mm; geometry (600 mm ÷ 640 px) gives 0.94 mm. Also sold as 108″ QHD and 162″ bundles.

Worked example: a 13 × 13 wall (16:9)

13 columns by 13 rows of this tile makes a 7.80 × 4.39 m wall, the closest this cabinet gets to 16:9, at 8,320 × 4,680 pixels (38.94 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 727 kg, carried by the structure it is mounted on.

On European power it draws 10.6 kW at full white (7.1 kW on typical content), which at an 80% derate is 5 × 16 A / 230 V circuits. Data comes to 91 runs at up to 2 panels per port, worst run 71% loaded, fitting 20 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R171%R271%R371%R471%R571%R671%R735%R871%R971%R1071%R1171%R1271%R1371%R1435%R1571%R1671%R1771%R1871%R1971%R2071%R2135%R2271%R2371%R2471%R2571%R2671%R2771%R2835%R2971%R3071%R3171%R3271%R3371%R3471%R3535%R3671%R3771%R3871%R3971%R4071%R4171%R4235%R4371%R4471%R4571%R4671%R4771%R4871%R4935%R5071%R5171%R5271%R5371%R5471%R5571%R5635%R5771%R5871%R5971%R6071%R6171%R6271%R6335%R6471%R6571%R6671%R6771%R6871%R6971%R7035%R7171%R7271%R7371%R7471%R7571%R7671%R7735%R7871%R7971%R8071%R8171%R8271%R8371%R8435%R8571%R8671%R8771%R8871%R8971%R9071%R9135%wall-mounted: the structure carries 727 kg7.80 m (8,320 px)4.39 m (4,680 px)10.6 kW max · 5× 16 A / 230 V · 91 runs on 20× NovaStar VX1000

Main: 13 × 13 Sharp LD-EC091

Size
7.80 × 4.39 m
Area
34.2 m²
Resolution
8,320 × 4,680 px
Pixels
38.94 M px
Panels
169 + 9 spares
Weight
727 kg panels only
Power
10.6 kW max, 7.1 kW typical, 5 circuits
Data
91 runs on 20 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSharp LD-EC09113 × 137.80 × 4.39 m8,320 × 4,680 pxwall-mounted
Panels
169 + 9 spares
Weight
727 kg panels only
Power
10.6 kW max, 7.1 kW typical, 5 circuits
Data
91 runs on 20 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 91 runs · up to 2 panels per run at 80% · worst 71% · 20× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 22 panels · 71% of port
Run 2Column 1, rows 3 to 42 panels · 71% of port
Run 3Column 1, rows 5 to 62 panels · 71% of port
Run 4Column 1, rows 7 to 82 panels · 71% of port
Run 5Column 1, rows 9 to 102 panels · 71% of port
Run 6Column 1, rows 11 to 122 panels · 71% of port
Run 7Column 1, rows 13 to 131 panels · 35% of port
Run 8Column 2, rows 1 to 22 panels · 71% of port
Run 9Column 2, rows 3 to 42 panels · 71% of port
Run 10Column 2, rows 5 to 62 panels · 71% of port
Run 11Column 2, rows 7 to 82 panels · 71% of port
Run 12Column 2, rows 9 to 102 panels · 71% of port
Run 13Column 2, rows 11 to 122 panels · 71% of port
Run 14Column 2, rows 13 to 131 panels · 35% of port
Run 15Column 3, rows 1 to 22 panels · 71% of port
Run 16Column 3, rows 3 to 42 panels · 71% of port
Run 17Column 3, rows 5 to 62 panels · 71% of port
Run 18Column 3, rows 7 to 82 panels · 71% of port
Run 19Column 3, rows 9 to 102 panels · 71% of port
Run 20Column 3, rows 11 to 122 panels · 71% of port
Run 21Column 3, rows 13 to 131 panels · 35% of port
Run 22Column 4, rows 1 to 22 panels · 71% of port
Run 23Column 4, rows 3 to 42 panels · 71% of port
Run 24Column 4, rows 5 to 62 panels · 71% of port
Run 25Column 4, rows 7 to 82 panels · 71% of port
Run 26Column 4, rows 9 to 102 panels · 71% of port
Run 27Column 4, rows 11 to 122 panels · 71% of port
Run 28Column 4, rows 13 to 131 panels · 35% of port
Run 29Column 5, rows 1 to 22 panels · 71% of port
Run 30Column 5, rows 3 to 42 panels · 71% of port
Run 31Column 5, rows 5 to 62 panels · 71% of port
Run 32Column 5, rows 7 to 82 panels · 71% of port
Run 33Column 5, rows 9 to 102 panels · 71% of port
Run 34Column 5, rows 11 to 122 panels · 71% of port
Run 35Column 5, rows 13 to 131 panels · 35% of port
Run 36Column 6, rows 1 to 22 panels · 71% of port
Run 37Column 6, rows 3 to 42 panels · 71% of port
Run 38Column 6, rows 5 to 62 panels · 71% of port
Run 39Column 6, rows 7 to 82 panels · 71% of port
Run 40Column 6, rows 9 to 102 panels · 71% of port
Run 41Column 6, rows 11 to 122 panels · 71% of port
Run 42Column 6, rows 13 to 131 panels · 35% of port
Run 43Column 7, rows 1 to 22 panels · 71% of port
Run 44Column 7, rows 3 to 42 panels · 71% of port
Run 45Column 7, rows 5 to 62 panels · 71% of port
Run 46Column 7, rows 7 to 82 panels · 71% of port
Run 47Column 7, rows 9 to 102 panels · 71% of port
Run 48Column 7, rows 11 to 122 panels · 71% of port
Run 49Column 7, rows 13 to 131 panels · 35% of port
Run 50Column 8, rows 1 to 22 panels · 71% of port
Run 51Column 8, rows 3 to 42 panels · 71% of port
Run 52Column 8, rows 5 to 62 panels · 71% of port
Run 53Column 8, rows 7 to 82 panels · 71% of port
Run 54Column 8, rows 9 to 102 panels · 71% of port
Run 55Column 8, rows 11 to 122 panels · 71% of port
Run 56Column 8, rows 13 to 131 panels · 35% of port
Run 57Column 9, rows 1 to 22 panels · 71% of port
Run 58Column 9, rows 3 to 42 panels · 71% of port
Run 59Column 9, rows 5 to 62 panels · 71% of port
Run 60Column 9, rows 7 to 82 panels · 71% of port
Run 61Column 9, rows 9 to 102 panels · 71% of port
Run 62Column 9, rows 11 to 122 panels · 71% of port
Run 63Column 9, rows 13 to 131 panels · 35% of port
Run 64Column 10, rows 1 to 22 panels · 71% of port
Run 65Column 10, rows 3 to 42 panels · 71% of port
Run 66Column 10, rows 5 to 62 panels · 71% of port
Run 67Column 10, rows 7 to 82 panels · 71% of port
Run 68Column 10, rows 9 to 102 panels · 71% of port
Run 69Column 10, rows 11 to 122 panels · 71% of port
Run 70Column 10, rows 13 to 131 panels · 35% of port
Run 71Column 11, rows 1 to 22 panels · 71% of port
Run 72Column 11, rows 3 to 42 panels · 71% of port
Run 73Column 11, rows 5 to 62 panels · 71% of port
Run 74Column 11, rows 7 to 82 panels · 71% of port
Run 75Column 11, rows 9 to 102 panels · 71% of port
Run 76Column 11, rows 11 to 122 panels · 71% of port
Run 77Column 11, rows 13 to 131 panels · 35% of port
Run 78Column 12, rows 1 to 22 panels · 71% of port
Run 79Column 12, rows 3 to 42 panels · 71% of port
Run 80Column 12, rows 5 to 62 panels · 71% of port
Run 81Column 12, rows 7 to 82 panels · 71% of port
Run 82Column 12, rows 9 to 102 panels · 71% of port
Run 83Column 12, rows 11 to 122 panels · 71% of port
Run 84Column 12, rows 13 to 131 panels · 35% of port
Run 85Column 13, rows 1 to 22 panels · 71% of port
Run 86Column 13, rows 3 to 42 panels · 71% of port
Run 87Column 13, rows 5 to 62 panels · 71% of port
Run 88Column 13, rows 7 to 82 panels · 71% of port
Run 89Column 13, rows 9 to 102 panels · 71% of port
Run 90Column 13, rows 11 to 122 panels · 71% of port
Run 91Column 13, rows 13 to 131 panels · 35% of port

Power runs 5 circuits · up to 39 panels/circuit · 10.6 kW max · 1× distro

Circuit 1Columns 1 to 3, snake up and down, hops right39 panels · 2,457 W · 83% · Distro 1 · L1
Circuit 2Columns 4 to 6, snake up and down, hops right39 panels · 2,457 W · 83% · Distro 1 · L2
Circuit 3Columns 7 to 9, snake up and down, hops right39 panels · 2,457 W · 83% · Distro 1 · L3
Circuit 4Columns 10 to 11, snake up and down, hops right26 panels · 1,638 W · 56% · Distro 1 · L1
Circuit 5Columns 12 to 13, snake up and down, hops right26 panels · 1,638 W · 56% · Distro 1 · L2
PatchDistro 1: circuits 1 to 5 (L1×2 L2×2 L3×1)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 727 kg over 7.80 × 4.39 m, about 21 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 46 panels per 16 A / 230 V circuit (63 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 3 columns need 5 circuits (single columns would need 13, full rows 13).
  5. openPower for a permanent install comes as 5 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 2 panels per run, giving 91 runs, each looped back to a B port on a second unit, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 429 tags · 91 data runs · 5 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

169 pcsSharp LD-EC091 tiles13×13 wall, 7.8×4.4 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 727 kg, about 21 kg/m²

Power 0/2 done

5 pcsHouse circuits (16 A / 230 V)10.6 kW max · ~7.1 kW typical content · from the building's board
181 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

20 pcsNovaStar VX1000182/200 ports used (A and B, 10 + 10 units)
182 pcsCat6A home runs, ~39 mrun + height + 5 m loop, A and B
186 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Sharp panels

The EC Series (Essential) series has 4 panels: the Sharp EC Series (Essential) series compared.

Where this panel sits

This sheet is listed under Sharp LED panels, the 0.9 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.