This sheet gives the datasheet figures for the Samsung The Wall IWA IW012A, a 1.26 mm LED panel in a 806.4 × 453.6 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSamsung, The Wall IWA series
Pixel pitch1.26 mm
Cabinet size806.4 × 453.6 × 36.5 mm
Pixels per cabinet640 × 360 (230,400 px)
Weight11.2 kg (31 kg/m²)
Max power, full white140 W (383 W/m²)
Typical power85 W
Refresh rate11,520 Hz
Brightness800 nits
Viewing angle (H / V)170° / 155°
Optical figuresthe catalogue calls 11,520 Hz a visual refresh rate; brightness 800 nit maximum, 1,600 nit peak
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly4 (our packing assumption)

Source: Samsung: The Wall catalogue (IWB update, 2022-10), retrieved 2026-09-17. Fixed-install Micro LED cabinet, front service, IP20, 30.6 kg/m². Catalogue gives 383/233 W/m² and 140/85 W per cabinet. No hanging limit published, so the hang figure is a conservative placeholder; the structure is designed for the site.

Worked example: a 10 × 10 wall (16:9)

10 columns by 10 rows of this tile makes a 8.06 × 4.54 m wall, the closest this cabinet gets to 16:9, at 6,400 × 3,600 pixels (23.04 MP): 100 panels plus 5 spares at the one-off rate. It weighs about 1,120 kg, carried by the structure it is mounted on.

On European power it draws 14 kW at full white (8.5 kW on typical content), which at an 80% derate is 5 × 16 A / 230 V circuits. Data comes to 50 runs at up to 2 panels per port, worst run 71% loaded, fitting 10 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R171%R271%R371%R471%R571%R671%R771%R871%R971%R1071%R1171%R1271%R1371%R1471%R1571%R1671%R1771%R1871%R1971%R2071%R2171%R2271%R2371%R2471%R2571%R2671%R2771%R2871%R2971%R3071%R3171%R3271%R3371%R3471%R3571%R3671%R3771%R3871%R3971%R4071%R4171%R4271%R4371%R4471%R4571%R4671%R4771%R4871%R4971%R5071%wall-mounted: the structure carries 1,120 kg8.06 m (6,400 px)4.54 m (3,600 px)14 kW max · 5× 16 A / 230 V · 50 runs on 10× NovaStar VX1000

Main: 10 × 10 Samsung IW012A

Size
8.06 × 4.54 m
Diagonal
364 in
Area
36.6 m²
Resolution
6,400 × 3,600 px
Pixels
23.04 M px
Panels
100 + 5 spares
Weight
1,120 kg panels only
Power
14 kW max, 8.5 kW typical, 5 circuits
Data
50 runs on 10 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSamsung IW012A10 × 108.06 × 4.54 m · 364 in6,400 × 3,600 pxwall-mounted
Panels
100 + 5 spares
Weight
1,120 kg panels only
Power
14 kW max, 8.5 kW typical, 5 circuits
Data
50 runs on 10 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 50 runs · up to 2 panels per run at 80% · worst 71% · 10× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 22 panels · 71% of port
Run 2Column 1, rows 3 to 42 panels · 71% of port
Run 3Column 1, rows 5 to 62 panels · 71% of port
Run 4Column 1, rows 7 to 82 panels · 71% of port
Run 5Column 1, rows 9 to 102 panels · 71% of port
Run 6Column 2, rows 1 to 22 panels · 71% of port
Run 7Column 2, rows 3 to 42 panels · 71% of port
Run 8Column 2, rows 5 to 62 panels · 71% of port
Run 9Column 2, rows 7 to 82 panels · 71% of port
Run 10Column 2, rows 9 to 102 panels · 71% of port
Run 11Column 3, rows 1 to 22 panels · 71% of port
Run 12Column 3, rows 3 to 42 panels · 71% of port
Run 13Column 3, rows 5 to 62 panels · 71% of port
Run 14Column 3, rows 7 to 82 panels · 71% of port
Run 15Column 3, rows 9 to 102 panels · 71% of port
Run 16Column 4, rows 1 to 22 panels · 71% of port
Run 17Column 4, rows 3 to 42 panels · 71% of port
Run 18Column 4, rows 5 to 62 panels · 71% of port
Run 19Column 4, rows 7 to 82 panels · 71% of port
Run 20Column 4, rows 9 to 102 panels · 71% of port
Run 21Column 5, rows 1 to 22 panels · 71% of port
Run 22Column 5, rows 3 to 42 panels · 71% of port
Run 23Column 5, rows 5 to 62 panels · 71% of port
Run 24Column 5, rows 7 to 82 panels · 71% of port
Run 25Column 5, rows 9 to 102 panels · 71% of port
Run 26Column 6, rows 1 to 22 panels · 71% of port
Run 27Column 6, rows 3 to 42 panels · 71% of port
Run 28Column 6, rows 5 to 62 panels · 71% of port
Run 29Column 6, rows 7 to 82 panels · 71% of port
Run 30Column 6, rows 9 to 102 panels · 71% of port
Run 31Column 7, rows 1 to 22 panels · 71% of port
Run 32Column 7, rows 3 to 42 panels · 71% of port
Run 33Column 7, rows 5 to 62 panels · 71% of port
Run 34Column 7, rows 7 to 82 panels · 71% of port
Run 35Column 7, rows 9 to 102 panels · 71% of port
Run 36Column 8, rows 1 to 22 panels · 71% of port
Run 37Column 8, rows 3 to 42 panels · 71% of port
Run 38Column 8, rows 5 to 62 panels · 71% of port
Run 39Column 8, rows 7 to 82 panels · 71% of port
Run 40Column 8, rows 9 to 102 panels · 71% of port
Run 41Column 9, rows 1 to 22 panels · 71% of port
Run 42Column 9, rows 3 to 42 panels · 71% of port
Run 43Column 9, rows 5 to 62 panels · 71% of port
Run 44Column 9, rows 7 to 82 panels · 71% of port
Run 45Column 9, rows 9 to 102 panels · 71% of port
Run 46Column 10, rows 1 to 22 panels · 71% of port
Run 47Column 10, rows 3 to 42 panels · 71% of port
Run 48Column 10, rows 5 to 62 panels · 71% of port
Run 49Column 10, rows 7 to 82 panels · 71% of port
Run 50Column 10, rows 9 to 102 panels · 71% of port

Power runs 5 circuits · up to 20 panels/circuit · 14 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right20 panels · 2,800 W · 95% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right20 panels · 2,800 W · 95% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right20 panels · 2,800 W · 95% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right20 panels · 2,800 W · 95% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right20 panels · 2,800 W · 95% · Distro 1 · L2
PatchDistro 1: circuits 1 to 5 (L1×2 L2×2 L3×1)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,120 kg over 8.06 × 4.54 m, about 31 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 21 panels per 16 A / 230 V circuit (140 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 5 circuits (single columns would need 10, full rows 10).
  5. openPower for a permanent install comes as 5 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 2 panels per run, giving 50 runs, each looped back to a B port on a second unit, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 250 tags · 50 data runs · 5 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

100 pcsSamsung The Wall IW012A tiles10×10 wall, 8.1×4.5 m
5 pcsSpare tilesone-off rate 5%
4 pcsSpare receiving cards
4 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,120 kg, about 31 kg/m²

Power 0/2 done

5 pcsHouse circuits (16 A / 230 V)14 kW max · ~8.5 kW typical content · from the building's board
105 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

10 pcsNovaStar VX1000100/100 ports used (A and B, 5 + 5 units)
100 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
111 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Samsung panels

The The Wall IWA series has 3 panels: the Samsung The Wall IWA series compared.

Where this panel sits

This sheet is listed under Samsung LED panels, the 1.2 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.