RigPlan.app

Samsung IF060H-D · 6 mm

This sheet gives the datasheet figures for the Samsung IF060H-D, a 6 mm LED panel in a 480 × 720 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSamsung, IF Series series
Pixel pitch6 mm
Cabinet size480 × 720 × 65 mm
Pixels per cabinet80 × 120 (9,600 px)
Weight7.4 kg (21 kg/m²)
Max power, full white200 W (579 W/m²)
Typical power67 W
Refresh rate3,840 Hz
Brightness1,200 nits
Viewing angle (H / V)160° / 160°
Optical figuressheet gives 1,920/3,840 Hz; 1,200 cd/m² after calibration, 2,400 peak
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly6 (our packing assumption)

Source: Samsung: IF060H-D Datenblatt, retrieved 2026-09-17. Fixed-installation cabinet in the 480 × 720 mm format, front and rear service, IP20, fanless. Datasheet power 580/193 W/m² and 200/67 W per cabinet, the same figures as the IF025H-D. No hanging limit published, so the hang figure is a conservative placeholder.

Worked example: a 16 × 6 wall (16:9)

16 columns by 6 rows of this tile makes a 7.68 × 4.32 m wall, the closest this cabinet gets to 16:9, at 1,280 × 720 pixels (0.92 MP): 96 panels plus 5 spares at the one-off rate. It weighs about 710 kg, carried by the structure it is mounted on.

On European power it draws 19.2 kW at full white (6.4 kW on typical content), which at an 80% derate is 8 × 16 A / 230 V circuits. Data comes to 2 runs at up to 54 panels per port, worst run 71% loaded, fitting 2 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R171%R271%wall-mounted: the structure carries 710 kg7.68 m (1,280 px)4.32 m (720 px)19.2 kW max · 8× 16 A / 230 V · 2 runs on 2× NovaStar VX1000

Main: 16 × 6 Samsung IF060H-D

Size
7.68 × 4.32 m
Diagonal
347 in
Area
33.2 m²
Resolution
1,280 × 720 px
Pixels
0.92 M px
Panels
96 + 5 spares
Weight
710 kg panels only
Power
19.2 kW max, 6.4 kW typical, 8 circuits
Data
2 runs on 2 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSamsung IF060H-D16 × 67.68 × 4.32 m · 347 in1,280 × 720 pxwall-mounted
Panels
96 + 5 spares
Weight
710 kg panels only
Power
19.2 kW max, 6.4 kW typical, 8 circuits
Data
2 runs on 2 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 2 runs · up to 54 panels per run at 80% · worst 71% · 2× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 848 panels · 71% of port
Run 2Columns 9 to 1648 panels · 71% of port

Power runs 8 circuits · up to 12 panels/circuit · 19.2 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 7Columns 13 to 14, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 8Columns 15 to 16, snake up and down, hops right12 panels · 2,400 W · 82% · Distro 1 · L2
PatchDistro 1: circuits 1 to 8 (L1×3 L2×3 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 710 kg over 7.68 × 4.32 m, about 21 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 14 panels per 16 A / 230 V circuit (200 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 8 circuits (single columns would need 16, full rows 12).
  5. openPower for a permanent install comes as 8 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 54 panels per run, giving 2 runs, each looped back to a B port on a second unit, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 194 tags · 2 data runs · 8 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

96 pcsSamsung IF060H-D tiles16×6 wall, 7.7×4.3 m
5 pcsSpare tilesone-off rate 5%
4 pcsSpare receiving cards
4 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 710 kg, about 21 kg/m²

Power 0/2 done

8 pcsHouse circuits (16 A / 230 V)19.2 kW max · ~6.4 kW typical content · from the building's board
97 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

2 pcsNovaStar VX10004/20 ports used (A and B, 1 + 1 units)
4 pcsCat6A home runs, ~39 mrun + height + 5 m loop, A and B
106 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Samsung panels

The IF Series series has 5 panels: the Samsung IF Series series compared.

Where this panel sits

This sheet is listed under Samsung LED panels, the 5.9 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.