ProLights AlphaPix 6T · 6.667 mm

This sheet gives the datasheet figures for the ProLights AlphaPix 6T, a 6.667 mm LED panel in a 640 × 720 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerProLights, AlphaPix series
Pixel pitch6.667 mm
Cabinet size640 × 720 × 100 mm
Pixels per cabinet96 × 108 (10,368 px)
Weight13.5 kg (29 kg/m²)
Max power, full white415 W (901 W/m²)
Typical power139 W
Refresh rate1,920 Hz
Brightness5,500 nits
Viewing angle (H / V)140° / 70°
Max hang15 panels
Hanging bar weightnot published by manufacturer
Panels per dolly4 (our packing assumption)

Source: ProLights: AlphaPix 6T product page (APIX6T), retrieved 2026-09-17. Outdoor rental cabinet, order code APIX6T, SMD 3535 high-power FC black face, IP65 (front), IP54 (back) for temporary outdoor use, hanging on the built-in clamp or ground stacked. Page gives 415/139 W maximum and average per panel (900/300 W/m²), 5,500 nits, 1,920 Hz and 13.5 kg; the maker publishes a hanging panel quantity of 15. Headline pitch 6.6 mm; the page’s own geometry (640 mm ÷ 96 px) gives 6.667 mm.

Worked example: a 12 × 6 wall (16:9)

12 columns by 6 rows of this tile makes a 7.68 × 4.32 m wall, the closest this cabinet gets to 16:9, at 1,152 × 648 pixels (0.75 MP): 72 panels plus 4 spares at the one-off rate. It weighs about 1,122 kg including bumpers, around 449 kg across each of 3 points.

On European power it draws 29.9 kW at full white (10 kW on typical content), which at an 80% derate is 12 × 16 A / 230 V circuits. Data comes to 2 runs at up to 50 panels per port, worst run 57% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R157%R257%2w2w2w2w2w2w~449 kg~449 kg~449 kg7.68 m (1,152 px)4.32 m (648 px)29.9 kW max · 12× 16 A / 230 V · 2 runs on 1× NovaStar VX1000

Main: 12 × 6 ProLights AlphaPix 6T

Size
7.68 × 4.32 m
Diagonal
347 in
Area
33.2 m²
Resolution
1,152 × 648 px
Pixels
0.75 M px
Panels
72 + 4 spares
Weight
1,122 kg incl. bumpers
Power
29.9 kW max, 10 kW typical, 12 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
5.2 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainProLights AlphaPix 6T12 × 67.68 × 4.32 m · 347 in1,152 × 648 pxflown
Panels
72 + 4 spares
Weight
1,122 kg incl. bumpers
Power
29.9 kW max, 10 kW typical, 12 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
5.2 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 2 runs · up to 50 panels per run at 80% · worst 57% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 636 panels · 57% of port
Run 2Columns 7 to 1236 panels · 57% of port

Power runs 12 circuits · up to 6 panels/circuit · 29.9 kW max · 1× distro

Circuit 1Column 16 panels · 2,490 W · 85% · Distro 1 · L1
Circuit 2Column 26 panels · 2,490 W · 85% · Distro 1 · L2
Circuit 3Column 36 panels · 2,490 W · 85% · Distro 1 · L3
Circuit 4Column 46 panels · 2,490 W · 85% · Distro 1 · L1
Circuit 5Column 56 panels · 2,490 W · 85% · Distro 1 · L2
Circuit 6Column 66 panels · 2,490 W · 85% · Distro 1 · L3
Circuit 7Column 76 panels · 2,490 W · 85% · Distro 1 · L1
Circuit 8Column 86 panels · 2,490 W · 85% · Distro 1 · L2
Circuit 9Column 96 panels · 2,490 W · 85% · Distro 1 · L3
Circuit 10Column 106 panels · 2,490 W · 85% · Distro 1 · L1
Circuit 11Column 116 panels · 2,490 W · 85% · Distro 1 · L2
Circuit 12Column 126 panels · 2,490 W · 85% · Distro 1 · L3
PatchDistro 1: circuits 1 to 12 (L1×4 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 12 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 7 panels per 16 A / 230 V circuit (415 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 12 circuits (full rows would need 12).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 50 panels per run, giving 2 runs, worst run 57%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 4 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 144 tags · 2 data runs · 12 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/22 packed

Panels 0/4 packed

72 pcsProLights AlphaPix 6T tiles12×6 wall, 7.7×4.3 m
4 pcsSpare tilesone-off rate 5%
3 pcsSpare receiving cards
3 pcsSpare PSUs

Rigging 0/6 packed

6 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~449 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro29.9 kW max · ~10 kW typical content
12 pcsFeeder lines to wall (16 A / 230 V)~30 m each
66 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10002/10 ports used
2 pcsCat6A home runs, ~39 mrun + height + 5 m loop
80 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

19 pcsPanel dollies4 tiles per dolly
1 pcsBumper cases8 per case
3 pcsCable trunks~160 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
5.2 mTruck deck, linear25 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app