Nanolumens Nixel 1.25 Flex · 1.25 mm

This sheet gives the datasheet figures for the Nanolumens Nixel 1.25 Flex, a 1.25 mm LED panel in a 300 × 168.8 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerNanolumens, Nixel Flex series
Pixel pitch1.25 mm
Cabinet size300 × 168.8 × 104.9 mm
Pixels per cabinet240 × 135 (32,400 px)
Weight1.26 kg (25 kg/m²)
Max power, full white37 W (731 W/m²)
Typical power11.1 W
Refresh ratenot published
Brightness770 nits
Viewing angle (H / V)170° / 170°
Optical figuresthe sheet gives 178° maximum and 170° / 170° at half brightness (L50), the figure stored; no refresh rate is printed
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Nanolumens: Nixel Series (Flex) spec sheet, retrieved 2026-09-17. Indoor fixed-install Nixel module in a bespoke flex frame curved to a minimum radius of 915 mm on standard framework, front service; the count is modules, not cabinets, and the depth is the sheet’s standard system depth of frame plus skin. Sheet gives 67.8 W/ft² maximum and 20.4 W/ft² average (730/220 W/m²) and 2.31 kg/ft² (24.9 kg/m²), converted at the 0.0506 m² module. No hanging limit is published, so the hang figure is a placeholder.

Worked example: a 27 × 30 wall (16:10)

27 columns by 30 rows of this tile makes a 8.10 × 5.06 m wall, the closest this cabinet gets to 16:10, at 6,480 × 4,050 pixels (26.24 MP): 810 panels plus 41 spares at the one-off rate. It weighs about 1,021 kg, carried by the structure it is mounted on.

On European power it draws 30 kW at full white (9 kW on typical content), which at an 80% derate is 14 × 16 A / 230 V circuits. Data comes to 54 runs at up to 16 panels per port, worst run 75% loaded, fitting 12 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R175%R275%R375%R475%R575%R675%R775%R875%R975%wall-mounted: the structure carries 1,021 kg8.10 m (6,480 px)5.06 m (4,050 px)30 kW max · 14× 16 A / 230 V · 54 runs on 12× NovaStar VX1000

Main: 27 × 30 Nanolumens Nixel 1.25 Flex

Size
8.10 × 5.06 m
Diagonal
376 in
Area
41.0 m²
Resolution
6,480 × 4,050 px
Pixels
26.24 M px
Panels
810 + 41 spares
Weight
1,021 kg panels only
Power
30 kW max, 9 kW typical, 14 circuits
Data
54 runs on 12 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainNanolumens Nixel 1.25 Flex27 × 308.10 × 5.06 m · 376 in6,480 × 4,050 pxwall-mounted
Panels
810 + 41 spares
Weight
1,021 kg panels only
Power
30 kW max, 9 kW typical, 14 circuits
Data
54 runs on 12 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 54 runs · up to 16 panels per run at 80% · worst 75% · 12× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 1515 panels · 75% of port
Run 2Column 1, rows 16 to 3015 panels · 75% of port
Run 3Column 2, rows 1 to 1515 panels · 75% of port
Run 4Column 2, rows 16 to 3015 panels · 75% of port
Run 5Column 3, rows 1 to 1515 panels · 75% of port
Run 6Column 3, rows 16 to 3015 panels · 75% of port
Run 7Column 4, rows 1 to 1515 panels · 75% of port
Run 8Column 4, rows 16 to 3015 panels · 75% of port
Run 9Column 5, rows 1 to 1515 panels · 75% of port
Run 10Column 5, rows 16 to 3015 panels · 75% of port
Run 11Column 6, rows 1 to 1515 panels · 75% of port
Run 12Column 6, rows 16 to 3015 panels · 75% of port
Run 13Column 7, rows 1 to 1515 panels · 75% of port
Run 14Column 7, rows 16 to 3015 panels · 75% of port
Run 15Column 8, rows 1 to 1515 panels · 75% of port
Run 16Column 8, rows 16 to 3015 panels · 75% of port
Run 17Column 9, rows 1 to 1515 panels · 75% of port
Run 18Column 9, rows 16 to 3015 panels · 75% of port
Run 19Column 10, rows 1 to 1515 panels · 75% of port
Run 20Column 10, rows 16 to 3015 panels · 75% of port
Run 21Column 11, rows 1 to 1515 panels · 75% of port
Run 22Column 11, rows 16 to 3015 panels · 75% of port
Run 23Column 12, rows 1 to 1515 panels · 75% of port
Run 24Column 12, rows 16 to 3015 panels · 75% of port
Run 25Column 13, rows 1 to 1515 panels · 75% of port
Run 26Column 13, rows 16 to 3015 panels · 75% of port
Run 27Column 14, rows 1 to 1515 panels · 75% of port
Run 28Column 14, rows 16 to 3015 panels · 75% of port
Run 29Column 15, rows 1 to 1515 panels · 75% of port
Run 30Column 15, rows 16 to 3015 panels · 75% of port
Run 31Column 16, rows 1 to 1515 panels · 75% of port
Run 32Column 16, rows 16 to 3015 panels · 75% of port
Run 33Column 17, rows 1 to 1515 panels · 75% of port
Run 34Column 17, rows 16 to 3015 panels · 75% of port
Run 35Column 18, rows 1 to 1515 panels · 75% of port
Run 36Column 18, rows 16 to 3015 panels · 75% of port
Run 37Column 19, rows 1 to 1515 panels · 75% of port
Run 38Column 19, rows 16 to 3015 panels · 75% of port
Run 39Column 20, rows 1 to 1515 panels · 75% of port
Run 40Column 20, rows 16 to 3015 panels · 75% of port
Run 41Column 21, rows 1 to 1515 panels · 75% of port
Run 42Column 21, rows 16 to 3015 panels · 75% of port
Run 43Column 22, rows 1 to 1515 panels · 75% of port
Run 44Column 22, rows 16 to 3015 panels · 75% of port
Run 45Column 23, rows 1 to 1515 panels · 75% of port
Run 46Column 23, rows 16 to 3015 panels · 75% of port
Run 47Column 24, rows 1 to 1515 panels · 75% of port
Run 48Column 24, rows 16 to 3015 panels · 75% of port
Run 49Column 25, rows 1 to 1515 panels · 75% of port
Run 50Column 25, rows 16 to 3015 panels · 75% of port
Run 51Column 26, rows 1 to 1515 panels · 75% of port
Run 52Column 26, rows 16 to 3015 panels · 75% of port
Run 53Column 27, rows 1 to 1515 panels · 75% of port
Run 54Column 27, rows 16 to 3015 panels · 75% of port

Power runs 14 circuits · up to 60 panels/circuit · 30 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L3
Circuit 7Columns 13 to 14, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L1
Circuit 8Columns 15 to 16, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L2
Circuit 9Columns 17 to 18, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L3
Circuit 10Columns 19 to 20, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L1
Circuit 11Columns 21 to 22, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L2
Circuit 12Columns 23 to 24, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L3
Circuit 13Columns 25 to 26, snake up and down, hops right60 panels · 2,220 W · 75% · Distro 1 · L1
Circuit 14Column 2730 panels · 1,110 W · 38% · Distro 1 · L2
PatchDistro 1: circuits 1 to 14 (L1×5 L2×5 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,021 kg over 8.10 × 5.06 m, about 25 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 79 panels per 16 A / 230 V circuit (37 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 14 circuits (single columns would need 27, full rows 30).
  5. openPower for a permanent install comes as 14 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 16 panels per run, giving 54 runs, each looped back to a B port on a second unit, worst run 75%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 1674 tags · 54 data runs · 14 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

810 pcsNanolumens Nixel 1.25 Flex tiles27×30 wall, 8.1×5.1 m
41 pcsSpare tilesone-off rate 5%
33 pcsSpare receiving cards
33 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,021 kg, about 25 kg/m²

Power 0/2 done

14 pcsHouse circuits (16 A / 230 V)30 kW max · ~9 kW typical content · from the building's board
876 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

12 pcsNovaStar VX1000108/120 ports used (A and B, 6 + 6 units)
108 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
892 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Nanolumens panels

The Nixel Flex series has 9 panels: the Nanolumens Nixel Flex series compared.

Where this panel sits

This sheet is listed under Nanolumens LED panels, the 1.2 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.