10 panels · 10 source documents · last read 17 September 2026 · rigplan.app/panels/manufacturer/barco/review
This sheet lists every value RigPlan stores for Barco panels, as stored, with the document each was read from and the day it was read. Write anything that disagrees with the current datasheet in the correction column and send the sheet back to erik@enrenterprises.com; corrections go live within a day.
Fixed-install flip-chip tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 488 W/m² (102 W per tile) maximum in standard mode, 699 W/m² (146 W) in high mode, 267 W/m² (56 W) typical; heat 2,384 BTU/h/m² maximum in high mode. No hanging limit published, so the hang figure is a conservative placeholder.
Fixed-install SMD tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 766 W/m² (160 W per tile) maximum and 280 W/m² (58 W) typical; heat 2,611 BTU/h/m² maximum. No hanging limit published, so the hang figure is a conservative placeholder.
Wall-mounted 27″ 16:9 install tile (Infinipix processing), 800 nits, IP30, front and back service. Spec sheet gives 704/302 W/m² (147/63 W per tile). Headline pitch 1.2 mm; geometry gives 1.27 mm. No hang limit published, so the hang figure is a conservative placeholder.
The essentials version of the XT1.2: 600 nits, IP30. Spec sheet gives 655/317 W/m² (137/66 W per tile). Geometry gives 1.27 mm. No hang limit published, so the hang figure is a conservative placeholder.
Fixed-install SMD tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 714 W/m² (149 W per tile) maximum and 245 W/m² (51 W) typical; heat 2,432 BTU/h/m² maximum. No hanging limit published, so the hang figure is a conservative placeholder.
Fixed-install flip-chip tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 378 W/m² (79 W per tile) maximum in standard mode, 581 W/m² (122 W) in high mode, 164 W/m² (34 W) typical; heat 1,981 BTU/h/m² maximum in high mode. No hanging limit published, so the hang figure is a conservative placeholder.
Essentials-line 27″ 16:9 install tile, 600 nits, IP30. Spec sheet gives 651/280 W/m² (136/59 W per tile). Headline pitch 1.5 mm; geometry gives 1.59 mm. No hang limit published, so the hang figure is a conservative placeholder.
Fixed-install SMD tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 703 W/m² (147 W per tile) maximum and 197 W/m² (41 W) typical; heat 2,394 BTU/h/m² maximum. No hanging limit published, so the hang figure is a conservative placeholder.
Fixed-install SMD tile, full front and full back service, inter-tile and signal-loop data redundancy standard, ceiling configurations supported. Sheet gives 640 W/m² (134 W per tile) maximum and 161 W/m² (34 W) typical; heat 2,182 BTU/h/m² maximum. No hanging limit published, so the hang figure is a conservative placeholder.
Indoor install tile in an unusual 400×450 format, 1,000 nits, front/back service, full data redundancy. Spec sheet gives 917 W/m² max (165 W per tile) and no typical figure, so the average shown is max ÷ 3. No hang limit published, so the hang figure is a conservative placeholder.