INFiLED ARmk2 IRAR4.8mk2 · 4.81 mm

This sheet gives the datasheet figures for the INFiLED ARmk2 IRAR4.8mk2, a 4.81 mm LED panel in a 500 × 1000 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerINFiLED, ARmk2 series
Pixel pitch4.81 mm
Cabinet size500 × 1000 mm
Pixels per cabinet104 × 208 (21,632 px)
Weight12.5 kg (25 kg/m²)
Max power, full white360 W (720 W/m²)
Typical power120 W
Refresh rate3,840 Hz
Brightness1,000 nits
Viewing angle (H / V)160° / 160°
Max hang20 panels
Hanging bar weightnot published by manufacturer
Panels per dolly6 (our packing assumption)

Source: INFiLED: ARmk2 series specifications, retrieved 2026-09-01. Indoor rental.

Worked example: a 16 × 5 wall (16:10)

16 columns by 5 rows of this tile makes a 8.00 × 5.00 m wall, the closest this cabinet gets to 16:10, at 1,664 × 1,040 pixels (1.73 MP): 80 panels plus 4 spares at the one-off rate. It weighs about 1,200 kg including bumpers, around 480 kg across each of 3 points.

On European power it draws 28.8 kW at full white (9.6 kW on typical content), which at an 80% derate is 10 × 16 A / 230 V circuits. Data comes to 4 runs at up to 24 panels per port, worst run 67% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R167%R267%R367%R467%2w2w2w2w2w2w2w2w~480 kg~480 kg~480 kg8.00 m (1,664 px)5.00 m (1,040 px)28.8 kW max · 10× 16 A / 230 V · 4 runs on 1× NovaStar VX1000

Main: 16 × 5 INFiLED IRAR4.8mk2

Size
8.00 × 5.00 m
Area
40.0 m²
Resolution
1,664 × 1,040 px
Pixels
1.73 M px
Panels
80 + 4 spares
Weight
1,200 kg incl. bumpers
Power
28.8 kW max, 9.6 kW typical, 10 circuits
Data
4 runs on 1 processor at 60 Hz 8-bit
Truck
4.2 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainINFiLED IRAR4.8mk216 × 58.00 × 5.00 m1,664 × 1,040 pxflown
Panels
80 + 4 spares
Weight
1,200 kg incl. bumpers
Power
28.8 kW max, 9.6 kW typical, 10 circuits
Data
4 runs on 1 processor at 60 Hz 8-bit
Truck
4.2 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 4 runs · up to 24 panels per run at 80% · worst 67% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 420 panels · 67% of port
Run 2Columns 5 to 820 panels · 67% of port
Run 3Columns 9 to 1220 panels · 67% of port
Run 4Columns 13 to 1620 panels · 67% of port

Power runs 10 circuits · up to 8 panels/circuit · 28.8 kW max · 1× distro

Circuit 1Row 1, columns 1 to 8, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L1
Circuit 2Row 1, columns 9 to 16, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L2
Circuit 3Row 2, columns 1 to 8, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L3
Circuit 4Row 2, columns 9 to 16, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L1
Circuit 5Row 3, columns 1 to 8, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L2
Circuit 6Row 3, columns 9 to 16, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L3
Circuit 7Row 4, columns 1 to 8, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L1
Circuit 8Row 4, columns 9 to 16, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L2
Circuit 9Row 5, columns 1 to 8, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L3
Circuit 10Row 5, columns 9 to 16, left to right (rear)8 panels · 2,880 W · 98% · Distro 1 · L1
PatchDistro 1: circuits 1 to 10 (L1×4 L2×3 L3×3)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 16 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 8 panels per 16 A / 230 V circuit (360 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Full rows fed left to right need 10 circuits against 16 vertical; rows win here.
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 24 panels per run, giving 4 runs, worst run 67%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 6 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 160 tags · 4 data runs · 10 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/22 packed

Panels 0/4 packed

80 pcsINFiLED IRAR4.8mk2 tiles16×5 wall, 8.0×5.0 m
4 pcsSpare tilesone-off rate 5%
4 pcsSpare receiving cards
4 pcsSpare PSUs

Rigging 0/6 packed

8 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~480 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro28.8 kW max · ~9.6 kW typical content
10 pcsFeeder lines to wall (16 A / 230 V)~30 m each
77 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10004/10 ports used
4 pcsCat6A home runs, ~40 mrun + height + 5 m loop
88 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

14 pcsPanel dollies6 tiles per dolly
1 pcsBumper cases8 per case
3 pcsCable trunks~179 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
4.2 mTruck deck, linear20 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app