ADJ AV6X · 6 mm

This sheet gives the datasheet figures for the ADJ AV6X, a 6 mm LED panel in a 576 × 576 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerADJ, AV series
Pixel pitch6 mm
Cabinet size576 × 576 × 75 mm
Pixels per cabinet96 × 96 (9,216 px)
Weight10.5 kg (32 kg/m²)
Max power, full white300 W (904 W/m²)
Typical power120 W
Refresh rate1,200 Hz
Brightness1,200 nits
Viewing angle (H / V)not published
Max hang20 panels
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: ADJ: AV6X product page and spec sheet, retrieved 2026-09-11. Spec sheet gives 300/120 W per panel. Hang limit from ADJ’s own rigging bar: AV6RB1 rigging bar connects up to 20 AV6 panels. The product page gives 23 lb / 10.5 kg, which agree; the spec sheet prints 23 lb / 8.15 kg, which do not, so 10.5 is stored.

Worked example: a 14 × 8 wall (16:9)

14 columns by 8 rows of this tile makes a 8.06 × 4.61 m wall, the closest this cabinet gets to 16:9, at 1,344 × 768 pixels (1.03 MP): 112 panels plus 6 spares at the one-off rate. It weighs about 1,351 kg including bumpers, around 540 kg across each of 3 points.

On European power it draws 33.6 kW at full white (13.4 kW on typical content), which at an 80% derate is 14 × 16 A / 230 V circuits. Data comes to 2 runs at up to 56 panels per port, worst run 79% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R179%R279%2w2w2w2w2w2w2w~540 kg~540 kg~540 kg8.06 m (1,344 px)4.61 m (768 px)33.6 kW max · 14× 16 A / 230 V · 2 runs on 1× NovaStar VX1000

Main: 14 × 8 ADJ AV6X

Size
8.06 × 4.61 m
Diagonal
366 in
Area
37.2 m²
Resolution
1,344 × 768 px
Pixels
1.03 M px
Panels
112 + 6 spares
Weight
1,351 kg incl. bumpers
Power
33.6 kW max, 13.4 kW typical, 14 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
4.8 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainADJ AV6X14 × 88.06 × 4.61 m · 366 in1,344 × 768 pxflown
Panels
112 + 6 spares
Weight
1,351 kg incl. bumpers
Power
33.6 kW max, 13.4 kW typical, 14 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
4.8 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 2 runs · up to 56 panels per run at 80% · worst 79% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 756 panels · 79% of port
Run 2Columns 8 to 1456 panels · 79% of port

Power runs 14 circuits · up to 8 panels/circuit · 33.6 kW max · 1× distro

Circuit 1Column 18 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 2Column 28 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 3Column 38 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 4Column 48 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 5Column 58 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 6Column 68 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 7Column 78 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 8Column 88 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 9Column 98 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 10Column 108 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 11Column 118 panels · 2,400 W · 82% · Distro 1 · L2
Circuit 12Column 128 panels · 2,400 W · 82% · Distro 1 · L3
Circuit 13Column 138 panels · 2,400 W · 82% · Distro 1 · L1
Circuit 14Column 148 panels · 2,400 W · 82% · Distro 1 · L2
PatchDistro 1: circuits 1 to 14 (L1×5 L2×5 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 14 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 9 panels per 16 A / 230 V circuit (300 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 14 circuits (full rows would need 16).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 56 panels per run, giving 2 runs, worst run 79%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 224 tags · 2 data runs · 14 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/22 packed

Panels 0/4 packed

112 pcsADJ AV6X tiles14×8 wall, 8.1×4.6 m
6 pcsSpare tilesone-off rate 5%
5 pcsSpare receiving cards
5 pcsSpare PSUs

Rigging 0/6 packed

7 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~540 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
10 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro33.6 kW max · ~13.4 kW typical content
14 pcsFeeder lines to wall (16 A / 230 V)~30 m each
108 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10002/10 ports used
2 pcsCat6A home runs, ~40 mrun + height + 5 m loop
124 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

15 pcsPanel dollies8 tiles per dolly
1 pcsBumper cases8 per case
5 pcsCable trunks~248 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
4.8 mTruck deck, linear23 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other ADJ panels

The AV series has 3 panels: the ADJ AV series compared.

Where this panel sits

This sheet is listed under ADJ LED panels, the 5.9 mm pixel pitch class, rental and touring LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.