Unilumin library: 23 panels, specs from Unilumin datasheets, last checked 9 October 2026. The planner opens on the UpanelS 1.9; pick another Unilumin panel or change the size and every figure recomputes: panels and spares, rigging, circuits, data runs, cases and the pack list.

R162%R253%R362%R453%R562%R653%R762%R853%R962%R1053%R1162%R1253%R1362%R1453%R1562%R1653%R1762%R1853%R1962%R2053%R2162%R2253%R2362%R2453%R2562%R2653%2w2w2w2w2w2w1w~573 kg~573 kg~573 kg7.93 m (4,160 px)4.46 m (2,340 px)23.7 kW max · 13× 16 A / 230 V · 26 runs on 3× NovaStar VX1000

Main: 13 × 13 Unilumin UpanelS 1.9

Size
7.93 × 4.46 m
Area
35.4 m²
Resolution
4,160 × 2,340 px
Pixels
9.73 M px
Panels
169 + 9 spares
Weight
1,433 kg incl. bumpers
Power
23.7 kW max, 7.8 kW typical, 13 circuits
Data
26 runs on 3 processors at 60 Hz 8-bit
Truck
7.3 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainUnilumin UpanelS 1.913 × 137.93 × 4.46 m4,160 × 2,340 pxflown
Panels
169 + 9 spares
Weight
1,433 kg incl. bumpers
Power
23.7 kW max, 7.8 kW typical, 13 circuits
Data
26 runs on 3 processors at 60 Hz 8-bit
Truck
7.3 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 26 runs · up to 9 panels per run at 80% · worst 62% · 3× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 77 panels · 62% of port
Run 2Column 1, rows 8 to 136 panels · 53% of port
Run 3Column 2, rows 1 to 77 panels · 62% of port
Run 4Column 2, rows 8 to 136 panels · 53% of port
Run 5Column 3, rows 1 to 77 panels · 62% of port
Run 6Column 3, rows 8 to 136 panels · 53% of port
Run 7Column 4, rows 1 to 77 panels · 62% of port
Run 8Column 4, rows 8 to 136 panels · 53% of port
Run 9Column 5, rows 1 to 77 panels · 62% of port
Run 10Column 5, rows 8 to 136 panels · 53% of port
Run 11Column 6, rows 1 to 77 panels · 62% of port
Run 12Column 6, rows 8 to 136 panels · 53% of port
Run 13Column 7, rows 1 to 77 panels · 62% of port
Run 14Column 7, rows 8 to 136 panels · 53% of port
Run 15Column 8, rows 1 to 77 panels · 62% of port
Run 16Column 8, rows 8 to 136 panels · 53% of port
Run 17Column 9, rows 1 to 77 panels · 62% of port
Run 18Column 9, rows 8 to 136 panels · 53% of port
Run 19Column 10, rows 1 to 77 panels · 62% of port
Run 20Column 10, rows 8 to 136 panels · 53% of port
Run 21Column 11, rows 1 to 77 panels · 62% of port
Run 22Column 11, rows 8 to 136 panels · 53% of port
Run 23Column 12, rows 1 to 77 panels · 62% of port
Run 24Column 12, rows 8 to 136 panels · 53% of port
Run 25Column 13, rows 1 to 77 panels · 62% of port
Run 26Column 13, rows 8 to 136 panels · 53% of port

Power runs 13 circuits · up to 13 panels/circuit · 23.7 kW max · 1× distro

Circuit 1Column 113 panels · 1,820 W · 62% · Distro 1 · L1
Circuit 2Column 213 panels · 1,820 W · 62% · Distro 1 · L2
Circuit 3Column 313 panels · 1,820 W · 62% · Distro 1 · L3
Circuit 4Column 413 panels · 1,820 W · 62% · Distro 1 · L1
Circuit 5Column 513 panels · 1,820 W · 62% · Distro 1 · L2
Circuit 6Column 613 panels · 1,820 W · 62% · Distro 1 · L3
Circuit 7Column 713 panels · 1,820 W · 62% · Distro 1 · L1
Circuit 8Column 813 panels · 1,820 W · 62% · Distro 1 · L2
Circuit 9Column 913 panels · 1,820 W · 62% · Distro 1 · L3
Circuit 10Column 1013 panels · 1,820 W · 62% · Distro 1 · L1
Circuit 11Column 1113 panels · 1,820 W · 62% · Distro 1 · L2
Circuit 12Column 1213 panels · 1,820 W · 62% · Distro 1 · L3
Circuit 13Column 1313 panels · 1,820 W · 62% · Distro 1 · L1
PatchDistro 1: circuits 1 to 13 (L1×5 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 21 panels per 16 A / 230 V circuit (140 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 13).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 9 panels per run, giving 26 runs, worst run 62%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 338 tags · 26 data runs · 13 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

169 pcsUnilumin UpanelS 1.9 tiles13×13 wall, 7.9×4.5 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
1 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~573 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro23.7 kW max · ~7.8 kW typical content
13 pcsFeeder lines to wall (16 A / 230 V)~30 m each
172 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

3 pcsNovaStar VX100026/30 ports used
26 pcsCat6A home runs, ~39 mrun + height + 5 m loop
186 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

23 pcsPanel dollies8 tiles per dolly
1 pcsBumper cases8 per case
7 pcsCable trunks~397 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
7.3 mTruck deck, linear35 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Where the figures come from

Every Unilumin figure is transcribed from the datasheet linked under the panel picker, and each panel on the Unilumin panel list shows its document and retrieval date. Where a sheet is silent the page says “not published”. For a check against the current sheets, the review sheet lists every stored value.