Planar library: 39 panels, specs from Planar datasheets, last checked 9 October 2026. The planner opens on the TVF014; pick another Planar panel or change the size and every figure recomputes: panels and spares, rigging, circuits, data runs, cases and the pack list.

R175%R260%R360%R475%R560%R660%R775%R860%R960%R1075%R1160%R1260%R1375%R1460%R1560%R1675%R1760%R1860%R1975%R2060%R2160%R2275%R2360%R2460%R2575%R2660%R2760%R2875%R2960%R3060%R3175%R3260%R3360%R3475%R3560%R3660%R3775%R3860%R3960%wall-mounted: the structure carries 904 kg7.86 m (5,408 px)4.42 m (3,042 px)20.8 kW max · 13× 16 A / 230 V · 39 runs on 8× NovaStar VX1000

Main: 13 × 13 Planar TVF014

Size
7.86 × 4.42 m
Area
34.8 m²
Resolution
5,408 × 3,042 px
Pixels
16.45 M px
Panels
169 + 9 spares
Weight
904 kg panels only
Power
20.8 kW max, 8.6 kW typical, 13 circuits
Data
39 runs on 8 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainPlanar TVF01413 × 137.86 × 4.42 m5,408 × 3,042 pxwall-mounted
Panels
169 + 9 spares
Weight
904 kg panels only
Power
20.8 kW max, 8.6 kW typical, 13 circuits
Data
39 runs on 8 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 39 runs · up to 5 panels per run at 80% · worst 75% · 8× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 55 panels · 75% of port
Run 2Column 1, rows 6 to 94 panels · 60% of port
Run 3Column 1, rows 10 to 134 panels · 60% of port
Run 4Column 2, rows 1 to 55 panels · 75% of port
Run 5Column 2, rows 6 to 94 panels · 60% of port
Run 6Column 2, rows 10 to 134 panels · 60% of port
Run 7Column 3, rows 1 to 55 panels · 75% of port
Run 8Column 3, rows 6 to 94 panels · 60% of port
Run 9Column 3, rows 10 to 134 panels · 60% of port
Run 10Column 4, rows 1 to 55 panels · 75% of port
Run 11Column 4, rows 6 to 94 panels · 60% of port
Run 12Column 4, rows 10 to 134 panels · 60% of port
Run 13Column 5, rows 1 to 55 panels · 75% of port
Run 14Column 5, rows 6 to 94 panels · 60% of port
Run 15Column 5, rows 10 to 134 panels · 60% of port
Run 16Column 6, rows 1 to 55 panels · 75% of port
Run 17Column 6, rows 6 to 94 panels · 60% of port
Run 18Column 6, rows 10 to 134 panels · 60% of port
Run 19Column 7, rows 1 to 55 panels · 75% of port
Run 20Column 7, rows 6 to 94 panels · 60% of port
Run 21Column 7, rows 10 to 134 panels · 60% of port
Run 22Column 8, rows 1 to 55 panels · 75% of port
Run 23Column 8, rows 6 to 94 panels · 60% of port
Run 24Column 8, rows 10 to 134 panels · 60% of port
Run 25Column 9, rows 1 to 55 panels · 75% of port
Run 26Column 9, rows 6 to 94 panels · 60% of port
Run 27Column 9, rows 10 to 134 panels · 60% of port
Run 28Column 10, rows 1 to 55 panels · 75% of port
Run 29Column 10, rows 6 to 94 panels · 60% of port
Run 30Column 10, rows 10 to 134 panels · 60% of port
Run 31Column 11, rows 1 to 55 panels · 75% of port
Run 32Column 11, rows 6 to 94 panels · 60% of port
Run 33Column 11, rows 10 to 134 panels · 60% of port
Run 34Column 12, rows 1 to 55 panels · 75% of port
Run 35Column 12, rows 6 to 94 panels · 60% of port
Run 36Column 12, rows 10 to 134 panels · 60% of port
Run 37Column 13, rows 1 to 55 panels · 75% of port
Run 38Column 13, rows 6 to 94 panels · 60% of port
Run 39Column 13, rows 10 to 134 panels · 60% of port

Power runs 13 circuits · up to 13 panels/circuit · 20.8 kW max · 1× distro

Circuit 1Column 113 panels · 1,599 W · 54% · Distro 1 · L1
Circuit 2Column 213 panels · 1,599 W · 54% · Distro 1 · L2
Circuit 3Column 313 panels · 1,599 W · 54% · Distro 1 · L3
Circuit 4Column 413 panels · 1,599 W · 54% · Distro 1 · L1
Circuit 5Column 513 panels · 1,599 W · 54% · Distro 1 · L2
Circuit 6Column 613 panels · 1,599 W · 54% · Distro 1 · L3
Circuit 7Column 713 panels · 1,599 W · 54% · Distro 1 · L1
Circuit 8Column 813 panels · 1,599 W · 54% · Distro 1 · L2
Circuit 9Column 913 panels · 1,599 W · 54% · Distro 1 · L3
Circuit 10Column 1013 panels · 1,599 W · 54% · Distro 1 · L1
Circuit 11Column 1113 panels · 1,599 W · 54% · Distro 1 · L2
Circuit 12Column 1213 panels · 1,599 W · 54% · Distro 1 · L3
Circuit 13Column 1313 panels · 1,599 W · 54% · Distro 1 · L1
PatchDistro 1: circuits 1 to 13 (L1×5 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 904 kg over 7.86 × 4.42 m, about 26 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 23 panels per 16 A / 230 V circuit (123 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 13).
  5. openPower for a permanent install comes as 13 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 5 panels per run, giving 39 runs, each looped back to a B port on a second unit, worst run 75%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 377 tags · 39 data runs · 13 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

169 pcsPlanar TVF014 tiles13×13 wall, 7.9×4.4 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 904 kg, about 26 kg/m²

Power 0/2 done

13 pcsHouse circuits (16 A / 230 V)20.8 kW max · ~8.6 kW typical content · from the building's board
172 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

8 pcsNovaStar VX100078/80 ports used (A and B, 4 + 4 units)
78 pcsCat6A home runs, ~39 mrun + height + 5 m loop, A and B
186 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Where the figures come from

Every Planar figure is transcribed from the datasheet linked under the panel picker, and each panel on the Planar panel list shows its document and retrieval date. Where a sheet is silent the page says “not published”. For a check against the current sheets, the review sheet lists every stored value.