Unilumin UpanelS MP 0.9 · 0.95 mm

This sheet gives the datasheet figures for the Unilumin UpanelS MP 0.9, a 0.95 mm LED panel in a 609.92 × 343.08 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerUnilumin, UpanelS MP series
Pixel pitch0.95 mm
Cabinet size609.92 × 343.08 × 71 mm
Pixels per cabinet640 × 360 (230,400 px)
Weight6.8 kg (32 kg/m²)
Max power, full white145 W (693 W/m²)
Typical power51 W
Refresh rate3,840 Hz
Brightness600 nits
Viewing angle (H / V)160° / 160°
Optical figuressheet gives refresh as 1,920 to 3,840 Hz
Max hang20 panels
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Unilumin USA: UpanelS MP 0.9 specifications sheet, retrieved 2026-09-02. Fixed-install 16:9 cabinet, 600 nits, rear IP50, 0.7 kg lighter than the original UpanelS. Datasheet states 20 tiles can be hung per column with a hanging beam.

Worked example: a 13 × 13 wall (16:9)

13 columns by 13 rows of this tile makes a 7.93 × 4.46 m wall, the closest this cabinet gets to 16:9, at 8,320 × 4,680 pixels (38.94 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 1,314 kg including bumpers, around 526 kg across each of 3 points.

On European power it draws 24.5 kW at full white (8.6 kW on typical content), which at an 80% derate is 13 × 16 A / 230 V circuits. Data comes to 91 runs at up to 2 panels per port, worst run 71% loaded, fitting 10 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R171%R271%R371%R471%R571%R671%R735%R871%R971%R1071%R1171%R1271%R1371%R1435%R1571%R1671%R1771%R1871%R1971%R2071%R2135%R2271%R2371%R2471%R2571%R2671%R2771%R2835%R2971%R3071%R3171%R3271%R3371%R3471%R3535%R3671%R3771%R3871%R3971%R4071%R4171%R4235%R4371%R4471%R4571%R4671%R4771%R4871%R4935%R5071%R5171%R5271%R5371%R5471%R5571%R5635%R5771%R5871%R5971%R6071%R6171%R6271%R6335%R6471%R6571%R6671%R6771%R6871%R6971%R7035%R7171%R7271%R7371%R7471%R7571%R7671%R7735%R7871%R7971%R8071%R8171%R8271%R8371%R8435%R8571%R8671%R8771%R8871%R8971%R9071%R9135%2w2w2w2w2w2w1w~526 kg~526 kg~526 kg7.93 m (8,320 px)4.46 m (4,680 px)24.5 kW max · 13× 16 A / 230 V · 91 runs on 10× NovaStar VX1000

Main: 13 × 13 Unilumin UpanelS MP 0.9

Size
7.93 × 4.46 m
Area
35.4 m²
Resolution
8,320 × 4,680 px
Pixels
38.94 M px
Panels
169 + 9 spares
Weight
1,314 kg incl. bumpers
Power
24.5 kW max, 8.6 kW typical, 13 circuits
Data
91 runs on 10 processors at 60 Hz 8-bit
Truck
9 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainUnilumin UpanelS MP 0.913 × 137.93 × 4.46 m8,320 × 4,680 pxflown
Panels
169 + 9 spares
Weight
1,314 kg incl. bumpers
Power
24.5 kW max, 8.6 kW typical, 13 circuits
Data
91 runs on 10 processors at 60 Hz 8-bit
Truck
9 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 91 runs · up to 2 panels per run at 80% · worst 71% · 10× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 22 panels · 71% of port
Run 2Column 1, rows 3 to 42 panels · 71% of port
Run 3Column 1, rows 5 to 62 panels · 71% of port
Run 4Column 1, rows 7 to 82 panels · 71% of port
Run 5Column 1, rows 9 to 102 panels · 71% of port
Run 6Column 1, rows 11 to 122 panels · 71% of port
Run 7Column 1, rows 13 to 131 panels · 35% of port
Run 8Column 2, rows 1 to 22 panels · 71% of port
Run 9Column 2, rows 3 to 42 panels · 71% of port
Run 10Column 2, rows 5 to 62 panels · 71% of port
Run 11Column 2, rows 7 to 82 panels · 71% of port
Run 12Column 2, rows 9 to 102 panels · 71% of port
Run 13Column 2, rows 11 to 122 panels · 71% of port
Run 14Column 2, rows 13 to 131 panels · 35% of port
Run 15Column 3, rows 1 to 22 panels · 71% of port
Run 16Column 3, rows 3 to 42 panels · 71% of port
Run 17Column 3, rows 5 to 62 panels · 71% of port
Run 18Column 3, rows 7 to 82 panels · 71% of port
Run 19Column 3, rows 9 to 102 panels · 71% of port
Run 20Column 3, rows 11 to 122 panels · 71% of port
Run 21Column 3, rows 13 to 131 panels · 35% of port
Run 22Column 4, rows 1 to 22 panels · 71% of port
Run 23Column 4, rows 3 to 42 panels · 71% of port
Run 24Column 4, rows 5 to 62 panels · 71% of port
Run 25Column 4, rows 7 to 82 panels · 71% of port
Run 26Column 4, rows 9 to 102 panels · 71% of port
Run 27Column 4, rows 11 to 122 panels · 71% of port
Run 28Column 4, rows 13 to 131 panels · 35% of port
Run 29Column 5, rows 1 to 22 panels · 71% of port
Run 30Column 5, rows 3 to 42 panels · 71% of port
Run 31Column 5, rows 5 to 62 panels · 71% of port
Run 32Column 5, rows 7 to 82 panels · 71% of port
Run 33Column 5, rows 9 to 102 panels · 71% of port
Run 34Column 5, rows 11 to 122 panels · 71% of port
Run 35Column 5, rows 13 to 131 panels · 35% of port
Run 36Column 6, rows 1 to 22 panels · 71% of port
Run 37Column 6, rows 3 to 42 panels · 71% of port
Run 38Column 6, rows 5 to 62 panels · 71% of port
Run 39Column 6, rows 7 to 82 panels · 71% of port
Run 40Column 6, rows 9 to 102 panels · 71% of port
Run 41Column 6, rows 11 to 122 panels · 71% of port
Run 42Column 6, rows 13 to 131 panels · 35% of port
Run 43Column 7, rows 1 to 22 panels · 71% of port
Run 44Column 7, rows 3 to 42 panels · 71% of port
Run 45Column 7, rows 5 to 62 panels · 71% of port
Run 46Column 7, rows 7 to 82 panels · 71% of port
Run 47Column 7, rows 9 to 102 panels · 71% of port
Run 48Column 7, rows 11 to 122 panels · 71% of port
Run 49Column 7, rows 13 to 131 panels · 35% of port
Run 50Column 8, rows 1 to 22 panels · 71% of port
Run 51Column 8, rows 3 to 42 panels · 71% of port
Run 52Column 8, rows 5 to 62 panels · 71% of port
Run 53Column 8, rows 7 to 82 panels · 71% of port
Run 54Column 8, rows 9 to 102 panels · 71% of port
Run 55Column 8, rows 11 to 122 panels · 71% of port
Run 56Column 8, rows 13 to 131 panels · 35% of port
Run 57Column 9, rows 1 to 22 panels · 71% of port
Run 58Column 9, rows 3 to 42 panels · 71% of port
Run 59Column 9, rows 5 to 62 panels · 71% of port
Run 60Column 9, rows 7 to 82 panels · 71% of port
Run 61Column 9, rows 9 to 102 panels · 71% of port
Run 62Column 9, rows 11 to 122 panels · 71% of port
Run 63Column 9, rows 13 to 131 panels · 35% of port
Run 64Column 10, rows 1 to 22 panels · 71% of port
Run 65Column 10, rows 3 to 42 panels · 71% of port
Run 66Column 10, rows 5 to 62 panels · 71% of port
Run 67Column 10, rows 7 to 82 panels · 71% of port
Run 68Column 10, rows 9 to 102 panels · 71% of port
Run 69Column 10, rows 11 to 122 panels · 71% of port
Run 70Column 10, rows 13 to 131 panels · 35% of port
Run 71Column 11, rows 1 to 22 panels · 71% of port
Run 72Column 11, rows 3 to 42 panels · 71% of port
Run 73Column 11, rows 5 to 62 panels · 71% of port
Run 74Column 11, rows 7 to 82 panels · 71% of port
Run 75Column 11, rows 9 to 102 panels · 71% of port
Run 76Column 11, rows 11 to 122 panels · 71% of port
Run 77Column 11, rows 13 to 131 panels · 35% of port
Run 78Column 12, rows 1 to 22 panels · 71% of port
Run 79Column 12, rows 3 to 42 panels · 71% of port
Run 80Column 12, rows 5 to 62 panels · 71% of port
Run 81Column 12, rows 7 to 82 panels · 71% of port
Run 82Column 12, rows 9 to 102 panels · 71% of port
Run 83Column 12, rows 11 to 122 panels · 71% of port
Run 84Column 12, rows 13 to 131 panels · 35% of port
Run 85Column 13, rows 1 to 22 panels · 71% of port
Run 86Column 13, rows 3 to 42 panels · 71% of port
Run 87Column 13, rows 5 to 62 panels · 71% of port
Run 88Column 13, rows 7 to 82 panels · 71% of port
Run 89Column 13, rows 9 to 102 panels · 71% of port
Run 90Column 13, rows 11 to 122 panels · 71% of port
Run 91Column 13, rows 13 to 131 panels · 35% of port

Power runs 13 circuits · up to 13 panels/circuit · 24.5 kW max · 1× distro

Circuit 1Column 113 panels · 1,885 W · 64% · Distro 1 · L1
Circuit 2Column 213 panels · 1,885 W · 64% · Distro 1 · L2
Circuit 3Column 313 panels · 1,885 W · 64% · Distro 1 · L3
Circuit 4Column 413 panels · 1,885 W · 64% · Distro 1 · L1
Circuit 5Column 513 panels · 1,885 W · 64% · Distro 1 · L2
Circuit 6Column 613 panels · 1,885 W · 64% · Distro 1 · L3
Circuit 7Column 713 panels · 1,885 W · 64% · Distro 1 · L1
Circuit 8Column 813 panels · 1,885 W · 64% · Distro 1 · L2
Circuit 9Column 913 panels · 1,885 W · 64% · Distro 1 · L3
Circuit 10Column 1013 panels · 1,885 W · 64% · Distro 1 · L1
Circuit 11Column 1113 panels · 1,885 W · 64% · Distro 1 · L2
Circuit 12Column 1213 panels · 1,885 W · 64% · Distro 1 · L3
Circuit 13Column 1313 panels · 1,885 W · 64% · Distro 1 · L1
PatchDistro 1: circuits 1 to 13 (L1×5 L2×4 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 20 panels per 16 A / 230 V circuit (145 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 13).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 2 panels per run, giving 91 runs, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 338 tags · 91 data runs · 13 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/23 packed

Panels 0/4 packed

169 pcsUnilumin UpanelS MP 0.9 tiles13×13 wall, 7.9×4.5 m
9 pcsSpare tilesone-off rate 5%
7 pcsSpare receiving cards
7 pcsSpare PSUs

Rigging 0/7 packed

6 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
1 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~526 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro24.5 kW max · ~8.6 kW typical content
13 pcsFeeder lines to wall (16 A / 230 V)~30 m each
172 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

10 pcsNovaStar VX100091/100 ports used
91 pcsCat6A home runs, ~39 mrun + height + 5 m loop
186 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

23 pcsPanel dollies8 tiles per dolly
1 pcsBumper cases8 per case
8 pcsCable trunks~462 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
9 mTruck deck, linear43 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Unilumin panels

The UpanelS MP series has 5 panels: the Unilumin UpanelS MP series compared.

Where this panel sits

This sheet is listed under Unilumin LED panels, the 0.9 mm pixel pitch class, fixed-install LED panels, rental and touring LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.