Main: 13 × 13 Unilumin UpanelS 1.5
- Size
- 7.93 × 4.46 m
- Area
- 35.4 m²
- Resolution
- 4,992 × 2,808 px
- Pixels
- 14.02 M px
- Panels
- 169 + 9 spares
- Weight
- 1,433 kg incl. bumpers
- Power
- 23.7 kW max, 7.8 kW typical, 13 circuits
- Data
- 39 runs on 4 processors at 60 Hz 8-bit
- Truck
- 7.5 m of deck
This is a live example. Change the panel and the size in the steps and every figure recomputes.
| Main | Unilumin UpanelS 1.5 | 13 × 13 | 7.93 × 4.46 m | 4,992 × 2,808 px | flown |
- Panels
- 169 + 9 spares
- Weight
- 1,433 kg incl. bumpers
- Power
- 23.7 kW max, 7.8 kW typical, 13 circuits
- Data
- 39 runs on 4 processors at 60 Hz 8-bit
- Truck
- 7.5 m of deck
The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 39 runs · up to 6 panels per run at 80% · worst 64% · 4× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
| Run 1 | Column 1, rows 1 to 5 | 5 panels · 64% of port |
| Run 2 | Column 1, rows 6 to 9 | 4 panels · 51% of port |
| Run 3 | Column 1, rows 10 to 13 | 4 panels · 51% of port |
| Run 4 | Column 2, rows 1 to 5 | 5 panels · 64% of port |
| Run 5 | Column 2, rows 6 to 9 | 4 panels · 51% of port |
| Run 6 | Column 2, rows 10 to 13 | 4 panels · 51% of port |
| Run 7 | Column 3, rows 1 to 5 | 5 panels · 64% of port |
| Run 8 | Column 3, rows 6 to 9 | 4 panels · 51% of port |
| Run 9 | Column 3, rows 10 to 13 | 4 panels · 51% of port |
| Run 10 | Column 4, rows 1 to 5 | 5 panels · 64% of port |
| Run 11 | Column 4, rows 6 to 9 | 4 panels · 51% of port |
| Run 12 | Column 4, rows 10 to 13 | 4 panels · 51% of port |
| Run 13 | Column 5, rows 1 to 5 | 5 panels · 64% of port |
| Run 14 | Column 5, rows 6 to 9 | 4 panels · 51% of port |
| Run 15 | Column 5, rows 10 to 13 | 4 panels · 51% of port |
| Run 16 | Column 6, rows 1 to 5 | 5 panels · 64% of port |
| Run 17 | Column 6, rows 6 to 9 | 4 panels · 51% of port |
| Run 18 | Column 6, rows 10 to 13 | 4 panels · 51% of port |
| Run 19 | Column 7, rows 1 to 5 | 5 panels · 64% of port |
| Run 20 | Column 7, rows 6 to 9 | 4 panels · 51% of port |
| Run 21 | Column 7, rows 10 to 13 | 4 panels · 51% of port |
| Run 22 | Column 8, rows 1 to 5 | 5 panels · 64% of port |
| Run 23 | Column 8, rows 6 to 9 | 4 panels · 51% of port |
| Run 24 | Column 8, rows 10 to 13 | 4 panels · 51% of port |
| Run 25 | Column 9, rows 1 to 5 | 5 panels · 64% of port |
| Run 26 | Column 9, rows 6 to 9 | 4 panels · 51% of port |
| Run 27 | Column 9, rows 10 to 13 | 4 panels · 51% of port |
| Run 28 | Column 10, rows 1 to 5 | 5 panels · 64% of port |
| Run 29 | Column 10, rows 6 to 9 | 4 panels · 51% of port |
| Run 30 | Column 10, rows 10 to 13 | 4 panels · 51% of port |
| Run 31 | Column 11, rows 1 to 5 | 5 panels · 64% of port |
| Run 32 | Column 11, rows 6 to 9 | 4 panels · 51% of port |
| Run 33 | Column 11, rows 10 to 13 | 4 panels · 51% of port |
| Run 34 | Column 12, rows 1 to 5 | 5 panels · 64% of port |
| Run 35 | Column 12, rows 6 to 9 | 4 panels · 51% of port |
| Run 36 | Column 12, rows 10 to 13 | 4 panels · 51% of port |
| Run 37 | Column 13, rows 1 to 5 | 5 panels · 64% of port |
| Run 38 | Column 13, rows 6 to 9 | 4 panels · 51% of port |
| Run 39 | Column 13, rows 10 to 13 | 4 panels · 51% of port |
Power runs 13 circuits · up to 13 panels/circuit · 23.7 kW max · 1× distro
| Circuit 1 | Column 1 | 13 panels · 1,820 W · 62% · Distro 1 · L1 |
| Circuit 2 | Column 2 | 13 panels · 1,820 W · 62% · Distro 1 · L2 |
| Circuit 3 | Column 3 | 13 panels · 1,820 W · 62% · Distro 1 · L3 |
| Circuit 4 | Column 4 | 13 panels · 1,820 W · 62% · Distro 1 · L1 |
| Circuit 5 | Column 5 | 13 panels · 1,820 W · 62% · Distro 1 · L2 |
| Circuit 6 | Column 6 | 13 panels · 1,820 W · 62% · Distro 1 · L3 |
| Circuit 7 | Column 7 | 13 panels · 1,820 W · 62% · Distro 1 · L1 |
| Circuit 8 | Column 8 | 13 panels · 1,820 W · 62% · Distro 1 · L2 |
| Circuit 9 | Column 9 | 13 panels · 1,820 W · 62% · Distro 1 · L3 |
| Circuit 10 | Column 10 | 13 panels · 1,820 W · 62% · Distro 1 · L1 |
| Circuit 11 | Column 11 | 13 panels · 1,820 W · 62% · Distro 1 · L2 |
| Circuit 12 | Column 12 | 13 panels · 1,820 W · 62% · Distro 1 · L3 |
| Circuit 13 | Column 13 | 13 panels · 1,820 W · 62% · Distro 1 · L1 |
| Patch | Distro 1: circuits 1 to 13 (L1×5 L2×4 L3×4) | |
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
- openSpare panels: 5% of wall count, minimum 2 (one-off).
- ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 13 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
- openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
- openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
- openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
- openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
- ✓ confirmedCircuits sized on max load (full white) at 80% derate: 21 panels per 16 A / 230 V circuit (140 W/panel). Typical draw shown separately for the venue/generator ask.
- ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 13).
- open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
- ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
- ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 6 panels per run, giving 39 runs, worst run 64%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
- ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
- openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
- openHome runs cut at run distance + wall height + 5 m service loop.
- openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
- ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
- openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
- openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 338 tags · 39 data runs · 13 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Copy tags as CSV 🔒The tag list, your own label format, and the CSV for a label printer are a Solo feature.
Panels 0/4 packed
| 169 pcs | Unilumin UpanelS 1.5 tiles | 13×13 wall, 7.9×4.5 m | ||
| 9 pcs | Spare tiles | one-off rate 5% | ||
| 7 pcs | Spare receiving cards | |||
| 7 pcs | Spare PSUs |
Rigging 0/7 packed
| 6 pcs | 2-wide bumpers | from your stock · 25 kg each (your standard) | ||
| 1 pcs | 1-wide bumpers | from your stock · 15 kg each (your standard) | ||
| 3 pcs | Chain hoists, 1 t | point load ~573 kg incl. 1.2 dyn. | ||
| 6 pcs | Steels, 1 m | 2 per point | ||
| 6 pcs | Spansets | 2 per point | ||
| 12 pcs | Shackles, 3.25 t | 4 per point | ||
| 9 m | Truss to span wall | +1 m overhang, or house points |
Power 0/3 packed
| 1 pcs | 63 A 3-phase distro | 23.7 kW max · ~7.8 kW typical content | ||
| 13 pcs | Feeder lines to wall (16 A / 230 V) | ~30 m each | ||
| 172 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
Data & control 0/3 packed
| 4 pcs | NovaStar VX1000 | 39/40 ports used | ||
| 39 pcs | Cat6A home runs, ~39 m | run + height + 5 m loop | ||
| 186 pcs | Cat6 panel jumpers | incl. 10% spare |
Cases & truck 0/6 packed
| 23 pcs | Panel dollies | 8 tiles per dolly | ||
| 1 pcs | Bumper cases | 8 per case | ||
| 7 pcs | Cable trunks | ~410 cables total | ||
| 1 pcs | Rigging trunks | |||
| 1 set | Gaff, velcro, zip ties, sharpies | always | ||
| 7.5 m | Truck deck, linear | 36 cases est. |