RigPlan.app

SiliconCore Magnolia 1.5 · 1.5 mm

This sheet gives the datasheet figures for the SiliconCore Magnolia 1.5, a 1.5 mm LED panel in a 480 × 270 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSiliconCore, Magnolia series
Pixel pitch1.5 mm
Cabinet size480 × 270 × 74.8 mm
Pixels per cabinet320 × 180 (57,600 px)
Weight7.2 kg (56 kg/m²)
Max power, full white111 W (856 W/m²)
Typical power37 W
Refresh rate3,840 Hz
Brightness1,500 nits
Viewing angle (H / V)160° / 160°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: SiliconCore: Magnolia 1.5 mm product page, retrieved 2026-09-17. Indoor fixed-install cabinet, SMD 0808, front service build listed (7.2 kg, 74.8 mm deep); the rear-service build is 95.4 mm deep at 7.6 kg. Two 240 × 270 mm modules. Page gives 856/285 W/m² maximum and typical at 1,500 nits and 556/185 W/m² at 800 nits. No hanging limit is published, so the hang figure is a placeholder.

Worked example: a 17 × 17 wall (16:9)

17 columns by 17 rows of this tile makes a 8.16 × 4.59 m wall, the closest this cabinet gets to 16:9, at 5,440 × 3,060 pixels (16.65 MP): 289 panels plus 15 spares at the one-off rate. It weighs about 2,081 kg, carried by the structure it is mounted on.

On European power it draws 32.1 kW at full white (10.7 kW on typical content), which at an 80% derate is 17 × 16 A / 230 V circuits. Data comes to 34 runs at up to 9 panels per port, worst run 80% loaded, fitting 8 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R180%R271%R380%R471%R580%R671%R780%R871%R980%R1071%R1180%R1271%R1380%R1471%R1580%R1671%R1780%R1871%R1980%R2071%R2180%R2271%R2380%R2471%R2580%R2671%R2780%R2871%R2980%R3071%R3180%R3271%R3380%R3471%wall-mounted: the structure carries 2,081 kg8.16 m (5,440 px)4.59 m (3,060 px)32.1 kW max · 17× 16 A / 230 V · 34 runs on 8× NovaStar VX1000

Main: 17 × 17 SiliconCore Magnolia 1.5

Size
8.16 × 4.59 m
Diagonal
369 in
Area
37.5 m²
Resolution
5,440 × 3,060 px
Pixels
16.65 M px
Panels
289 + 15 spares
Weight
2,081 kg panels only
Power
32.1 kW max, 10.7 kW typical, 17 circuits
Data
34 runs on 8 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSiliconCore Magnolia 1.517 × 178.16 × 4.59 m · 369 in5,440 × 3,060 pxwall-mounted
Panels
289 + 15 spares
Weight
2,081 kg panels only
Power
32.1 kW max, 10.7 kW typical, 17 circuits
Data
34 runs on 8 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 34 runs · up to 9 panels per run at 80% · worst 80% · 8× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 99 panels · 80% of port
Run 2Column 1, rows 10 to 178 panels · 71% of port
Run 3Column 2, rows 1 to 99 panels · 80% of port
Run 4Column 2, rows 10 to 178 panels · 71% of port
Run 5Column 3, rows 1 to 99 panels · 80% of port
Run 6Column 3, rows 10 to 178 panels · 71% of port
Run 7Column 4, rows 1 to 99 panels · 80% of port
Run 8Column 4, rows 10 to 178 panels · 71% of port
Run 9Column 5, rows 1 to 99 panels · 80% of port
Run 10Column 5, rows 10 to 178 panels · 71% of port
Run 11Column 6, rows 1 to 99 panels · 80% of port
Run 12Column 6, rows 10 to 178 panels · 71% of port
Run 13Column 7, rows 1 to 99 panels · 80% of port
Run 14Column 7, rows 10 to 178 panels · 71% of port
Run 15Column 8, rows 1 to 99 panels · 80% of port
Run 16Column 8, rows 10 to 178 panels · 71% of port
Run 17Column 9, rows 1 to 99 panels · 80% of port
Run 18Column 9, rows 10 to 178 panels · 71% of port
Run 19Column 10, rows 1 to 99 panels · 80% of port
Run 20Column 10, rows 10 to 178 panels · 71% of port
Run 21Column 11, rows 1 to 99 panels · 80% of port
Run 22Column 11, rows 10 to 178 panels · 71% of port
Run 23Column 12, rows 1 to 99 panels · 80% of port
Run 24Column 12, rows 10 to 178 panels · 71% of port
Run 25Column 13, rows 1 to 99 panels · 80% of port
Run 26Column 13, rows 10 to 178 panels · 71% of port
Run 27Column 14, rows 1 to 99 panels · 80% of port
Run 28Column 14, rows 10 to 178 panels · 71% of port
Run 29Column 15, rows 1 to 99 panels · 80% of port
Run 30Column 15, rows 10 to 178 panels · 71% of port
Run 31Column 16, rows 1 to 99 panels · 80% of port
Run 32Column 16, rows 10 to 178 panels · 71% of port
Run 33Column 17, rows 1 to 99 panels · 80% of port
Run 34Column 17, rows 10 to 178 panels · 71% of port

Power runs 17 circuits · up to 17 panels/circuit · 32.1 kW max · 1× distro

Circuit 1Column 117 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 2Column 217 panels · 1,887 W · 64% · Distro 1 · L2
Circuit 3Column 317 panels · 1,887 W · 64% · Distro 1 · L3
Circuit 4Column 417 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 5Column 517 panels · 1,887 W · 64% · Distro 1 · L2
Circuit 6Column 617 panels · 1,887 W · 64% · Distro 1 · L3
Circuit 7Column 717 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 8Column 817 panels · 1,887 W · 64% · Distro 1 · L2
Circuit 9Column 917 panels · 1,887 W · 64% · Distro 1 · L3
Circuit 10Column 1017 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 11Column 1117 panels · 1,887 W · 64% · Distro 1 · L2
Circuit 12Column 1217 panels · 1,887 W · 64% · Distro 1 · L3
Circuit 13Column 1317 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 14Column 1417 panels · 1,887 W · 64% · Distro 1 · L2
Circuit 15Column 1517 panels · 1,887 W · 64% · Distro 1 · L3
Circuit 16Column 1617 panels · 1,887 W · 64% · Distro 1 · L1
Circuit 17Column 1717 panels · 1,887 W · 64% · Distro 1 · L2
PatchDistro 1: circuits 1 to 17 (L1×6 L2×6 L3×5)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 2,081 kg over 8.16 × 4.59 m, about 56 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 26 panels per 16 A / 230 V circuit (111 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 17 circuits (full rows would need 17).
  5. openPower for a permanent install comes as 17 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 9 panels per run, giving 34 runs, each looped back to a B port on a second unit, worst run 80%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 612 tags · 34 data runs · 17 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

289 pcsSiliconCore Magnolia 1.5 tiles17×17 wall, 8.2×4.6 m
15 pcsSpare tilesone-off rate 5%
12 pcsSpare receiving cards
12 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 2,081 kg, about 56 kg/m²

Power 0/2 done

17 pcsHouse circuits (16 A / 230 V)32.1 kW max · ~10.7 kW typical content · from the building's board
300 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

8 pcsNovaStar VX100068/80 ports used (A and B, 4 + 4 units)
68 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
318 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other SiliconCore panels

The Magnolia series has 2 panels: the SiliconCore Magnolia series compared.

Where this panel sits

This sheet is listed under SiliconCore LED panels, the 1.5 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.