Samsung The Wall IWC IW016C · 1.68 mm

This sheet gives the datasheet figures for the Samsung The Wall IWC IW016C, a 1.68 mm LED panel in a 806.4 × 453.6 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerSamsung, The Wall IWC series
Pixel pitch1.68 mm
Cabinet size806.4 × 453.6 × 75 mm
Pixels per cabinet480 × 270 (129,600 px)
Weight11.4 kg (31 kg/m²)
Max power, full white163 W (446 W/m²)
Typical power75 W
Refresh rate7,680 Hz
Brightness1,200 nits
Viewing angle (H / V)170° / 155°
Optical figuresangles given as ±5°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly4 (our packing assumption)

Source: Samsung: The Wall IW016C product specifications, retrieved 2026-09-17. Fixed-install Micro LED cabinet, front service, IP20, 31.2 kg/m². Page gives 446/205 W/m² and 163/75 W per cabinet. No hanging limit published, so the hang figure is a conservative placeholder; the structure is designed for the site.

Worked example: a 10 × 10 wall (16:9)

10 columns by 10 rows of this tile makes a 8.06 × 4.54 m wall, the closest this cabinet gets to 16:9, at 4,800 × 2,700 pixels (12.96 MP): 100 panels plus 5 spares at the one-off rate. It weighs about 1,140 kg, carried by the structure it is mounted on.

On European power it draws 16.3 kW at full white (7.5 kW on typical content), which at an 80% derate is 10 × 16 A / 230 V circuits. Data comes to 30 runs at up to 4 panels per port, worst run 80% loaded, fitting 6 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R180%R260%R360%R480%R560%R660%R780%R860%R960%R1080%R1160%R1260%R1380%R1460%R1560%R1680%R1760%R1860%R1980%R2060%R2160%R2280%R2360%R2460%R2580%R2660%R2760%R2880%R2960%R3060%wall-mounted: the structure carries 1,140 kg8.06 m (4,800 px)4.54 m (2,700 px)16.3 kW max · 10× 16 A / 230 V · 30 runs on 6× NovaStar VX1000

Main: 10 × 10 Samsung IW016C

Size
8.06 × 4.54 m
Diagonal
364 in
Area
36.6 m²
Resolution
4,800 × 2,700 px
Pixels
12.96 M px
Panels
100 + 5 spares
Weight
1,140 kg panels only
Power
16.3 kW max, 7.5 kW typical, 10 circuits
Data
30 runs on 6 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainSamsung IW016C10 × 108.06 × 4.54 m · 364 in4,800 × 2,700 pxwall-mounted
Panels
100 + 5 spares
Weight
1,140 kg panels only
Power
16.3 kW max, 7.5 kW typical, 10 circuits
Data
30 runs on 6 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 30 runs · up to 4 panels per run at 80% · worst 80% · 6× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 44 panels · 80% of port
Run 2Column 1, rows 5 to 73 panels · 60% of port
Run 3Column 1, rows 8 to 103 panels · 60% of port
Run 4Column 2, rows 1 to 44 panels · 80% of port
Run 5Column 2, rows 5 to 73 panels · 60% of port
Run 6Column 2, rows 8 to 103 panels · 60% of port
Run 7Column 3, rows 1 to 44 panels · 80% of port
Run 8Column 3, rows 5 to 73 panels · 60% of port
Run 9Column 3, rows 8 to 103 panels · 60% of port
Run 10Column 4, rows 1 to 44 panels · 80% of port
Run 11Column 4, rows 5 to 73 panels · 60% of port
Run 12Column 4, rows 8 to 103 panels · 60% of port
Run 13Column 5, rows 1 to 44 panels · 80% of port
Run 14Column 5, rows 5 to 73 panels · 60% of port
Run 15Column 5, rows 8 to 103 panels · 60% of port
Run 16Column 6, rows 1 to 44 panels · 80% of port
Run 17Column 6, rows 5 to 73 panels · 60% of port
Run 18Column 6, rows 8 to 103 panels · 60% of port
Run 19Column 7, rows 1 to 44 panels · 80% of port
Run 20Column 7, rows 5 to 73 panels · 60% of port
Run 21Column 7, rows 8 to 103 panels · 60% of port
Run 22Column 8, rows 1 to 44 panels · 80% of port
Run 23Column 8, rows 5 to 73 panels · 60% of port
Run 24Column 8, rows 8 to 103 panels · 60% of port
Run 25Column 9, rows 1 to 44 panels · 80% of port
Run 26Column 9, rows 5 to 73 panels · 60% of port
Run 27Column 9, rows 8 to 103 panels · 60% of port
Run 28Column 10, rows 1 to 44 panels · 80% of port
Run 29Column 10, rows 5 to 73 panels · 60% of port
Run 30Column 10, rows 8 to 103 panels · 60% of port

Power runs 10 circuits · up to 10 panels/circuit · 16.3 kW max · 1× distro

Circuit 1Column 110 panels · 1,630 W · 55% · Distro 1 · L1
Circuit 2Column 210 panels · 1,630 W · 55% · Distro 1 · L2
Circuit 3Column 310 panels · 1,630 W · 55% · Distro 1 · L3
Circuit 4Column 410 panels · 1,630 W · 55% · Distro 1 · L1
Circuit 5Column 510 panels · 1,630 W · 55% · Distro 1 · L2
Circuit 6Column 610 panels · 1,630 W · 55% · Distro 1 · L3
Circuit 7Column 710 panels · 1,630 W · 55% · Distro 1 · L1
Circuit 8Column 810 panels · 1,630 W · 55% · Distro 1 · L2
Circuit 9Column 910 panels · 1,630 W · 55% · Distro 1 · L3
Circuit 10Column 1010 panels · 1,630 W · 55% · Distro 1 · L1
PatchDistro 1: circuits 1 to 10 (L1×4 L2×3 L3×3)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,140 kg over 8.06 × 4.54 m, about 31 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 18 panels per 16 A / 230 V circuit (163 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 10 circuits (full rows would need 10).
  5. openPower for a permanent install comes as 10 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 4 panels per run, giving 30 runs, each looped back to a B port on a second unit, worst run 80%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 230 tags · 30 data runs · 10 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

100 pcsSamsung The Wall IW016C tiles10×10 wall, 8.1×4.5 m
5 pcsSpare tilesone-off rate 5%
4 pcsSpare receiving cards
4 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,140 kg, about 31 kg/m²

Power 0/2 done

10 pcsHouse circuits (16 A / 230 V)16.3 kW max · ~7.5 kW typical content · from the building's board
100 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

6 pcsNovaStar VX100060/60 ports used (A and B, 3 + 3 units)
60 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
111 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app