This sheet gives the datasheet figures for the Nanolumens NXT 2.5 SMD, a 2.5 mm LED panel in a 600 × 337.5 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.
Spec sheet from the manufacturer datasheet
Manufacturer
Nanolumens, NXT series
Pixel pitch
2.5 mm
Cabinet size
600 × 337.5 × 50 mm
Pixels per cabinet
240 × 135 (32,400 px)
Weight
5.1 kg (25 kg/m²)
Max power, full white
126 W (622 W/m²)
Typical power
42 W
Refresh rate
not published
Brightness
800 nits
Viewing angle (H / V)
170° / 170°
Optical figures
the sheet gives 178° maximum and 170° / 170° at half brightness (L50), the figure stored; no refresh rate is printed
Max hang
not published by manufacturer
Hanging bar weight
not published by manufacturer
Panels per dolly
8 (our packing assumption)
Source: Nanolumens: NXT Series specification sheet, retrieved 2026-09-17. Indoor fixed-install cabinet in a 16:9 format, front service, faceted curves. SMD build; no mount required by the sheet. Sheet gives 58 W/ft² maximum and 19.3 W/ft² average (624/208 W/m²), marked as estimated, and 2.34 kg/ft² (25.2 kg/m²), converted at the 0.2025 m² module. No hanging limit is published, so the hang figure is a placeholder.
Worked example: a 13 × 13 wall (16:9)
13 columns by 13 rows of this tile makes a 7.80 × 4.39 m wall, the closest this cabinet gets to 16:9, at 3,120 × 1,755 pixels (5.48 MP): 169 panels plus 9 spares at the one-off rate. It weighs about 862 kg, carried by the structure it is mounted on.
On European power it draws 21.3 kW at full white (7.1 kW on typical content), which at an 80% derate is 13 × 16 A / 230 V circuits. Data comes to 13 runs at up to 16 panels per port, worst run 65% loaded, fitting 4 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.
Main: 13 × 13 Nanolumens NXT 2.5 SMD
Size
7.80 × 4.39 m
Diagonal
352 in
Area
34.2 m²
Resolution
3,120 × 1,755 px
Pixels
5.48 M px
Panels
169 + 9 spares
Weight
862 kg panels only
Power
21.3 kW max, 7.1 kW typical, 13 circuits
Data
13 runs on 4 processors at 60 Hz 8-bit
This is a live example. Change the panel and the size in the steps and every figure recomputes.
RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
Main
Nanolumens NXT 2.5 SMD
13 × 13
7.80 × 4.39 m · 352 in
3,120 × 1,755 px
wall-mounted
Panels
169 + 9 spares
Weight
862 kg panels only
Power
21.3 kW max, 7.1 kW typical, 13 circuits
Data
13 runs on 4 processors at 60 Hz 8-bit
The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 13 runs · up to 16 panels per run at 80% · worst 65% · 4× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
Run 1
Column 1
13 panels · 65% of port
Run 2
Column 2
13 panels · 65% of port
Run 3
Column 3
13 panels · 65% of port
Run 4
Column 4
13 panels · 65% of port
Run 5
Column 5
13 panels · 65% of port
Run 6
Column 6
13 panels · 65% of port
Run 7
Column 7
13 panels · 65% of port
Run 8
Column 8
13 panels · 65% of port
Run 9
Column 9
13 panels · 65% of port
Run 10
Column 10
13 panels · 65% of port
Run 11
Column 11
13 panels · 65% of port
Run 12
Column 12
13 panels · 65% of port
Run 13
Column 13
13 panels · 65% of port
Power runs 13 circuits · up to 13 panels/circuit · 21.3 kW max · 1× distro
Circuit 1
Column 1
13 panels · 1,638 W · 56% · Distro 1 · L1
Circuit 2
Column 2
13 panels · 1,638 W · 56% · Distro 1 · L2
Circuit 3
Column 3
13 panels · 1,638 W · 56% · Distro 1 · L3
Circuit 4
Column 4
13 panels · 1,638 W · 56% · Distro 1 · L1
Circuit 5
Column 5
13 panels · 1,638 W · 56% · Distro 1 · L2
Circuit 6
Column 6
13 panels · 1,638 W · 56% · Distro 1 · L3
Circuit 7
Column 7
13 panels · 1,638 W · 56% · Distro 1 · L1
Circuit 8
Column 8
13 panels · 1,638 W · 56% · Distro 1 · L2
Circuit 9
Column 9
13 panels · 1,638 W · 56% · Distro 1 · L3
Circuit 10
Column 10
13 panels · 1,638 W · 56% · Distro 1 · L1
Circuit 11
Column 11
13 panels · 1,638 W · 56% · Distro 1 · L2
Circuit 12
Column 12
13 panels · 1,638 W · 56% · Distro 1 · L3
Circuit 13
Column 13
13 panels · 1,638 W · 56% · Distro 1 · L1
Patch
Distro 1: circuits 1 to 13 (L1×5 L2×4 L3×4)
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
✓ confirmedWall-mounted: the wall or structure carries the panels, 862 kg over 7.80 × 4.39 m, about 25 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
✓ confirmedCircuits sized on max load (full white) at 80% derate: 23 panels per 16 A / 230 V circuit (126 W/panel). Typical draw shown separately for the venue/generator ask.
✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 13 circuits (full rows would need 13).
openPower for a permanent install comes as 13 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 16 panels per run, giving 13 runs, each looped back to a B port on a second unit, worst run 65%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
openHome runs cut at run distance + wall height + 5 m service loop.
openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 351 tags · 13 data runs · 13 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
site-specific, not derived; carries 862 kg, about 25 kg/m²
Power 0/2 done
13 pcs
House circuits (16 A / 230 V)
21.3 kW max · ~7.1 kW typical content · from the building's board
172 pcs
TRUE1 jumpers
panel-to-panel, incl. 10% spare
Data & control 0/3 done
4 pcs
NovaStar VX1000
26/40 ports used (A and B, 2 + 2 units)
26 pcs
Cat6A home runs, ~39 m
run + height + 5 m loop, A and B
186 pcs
Cat6 panel jumpers
incl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app