LG LSCC018-CZ · 1.88 mm

This sheet gives the datasheet figures for the LG LSCC018-CZ, a 1.88 mm LED panel in a 300 × 337.5 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerLG, LSCC series
Pixel pitch1.88 mm
Cabinet size300 × 337.5 × 32.6 mm
Pixels per cabinet160 × 180 (28,800 px)
Weight2.8 kg (28 kg/m²)
Max power, full white48 W (474 W/m²)
Typical power16 W
Refresh rate3,840 Hz
Brightness800 nits
Viewing angle (H / V)160° / 160°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: LG: LSCC Ultra Slim LED Signage datasheet (2025-09-10), retrieved 2026-10-09. Half-width flat cabinet (-CZ) of the LSCC018: wall-mounted install cabinet, 32.6 mm deep, front service, IP30, 800 nits. LG publishes per-cabinet power directly: 48/16 W, and its 474 W/m² max times the 0.101 m² face gives the same 48 W. The curved -CZF is left out. No hang limit published, so the hang figure is a conservative placeholder.

Worked example: a 27 × 15 wall (16:10)

27 columns by 15 rows of this tile makes a 8.10 × 5.06 m wall, the closest this cabinet gets to 16:10, at 4,320 × 2,700 pixels (11.66 MP): 405 panels plus 21 spares at the one-off rate. It weighs about 1,134 kg, carried by the structure it is mounted on.

On European power it draws 19.4 kW at full white (6.5 kW on typical content), which at an 80% derate is 7 × 16 A / 230 V circuits. Data comes to 27 runs at up to 18 panels per port, worst run 66% loaded, fitting 6 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R166%R266%R366%R466%R566%R666%R766%R866%R966%wall-mounted: the structure carries 1,134 kg8.10 m (4,320 px)5.06 m (2,700 px)19.4 kW max · 7× 16 A / 230 V · 27 runs on 6× NovaStar VX1000

Main: 27 × 15 LG LSCC018-CZ

Size
8.10 × 5.06 m
Area
41.0 m²
Resolution
4,320 × 2,700 px
Pixels
11.66 M px
Panels
405 + 21 spares
Weight
1,134 kg panels only
Power
19.4 kW max, 6.5 kW typical, 7 circuits
Data
27 runs on 6 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainLG LSCC018-CZ27 × 158.10 × 5.06 m4,320 × 2,700 pxwall-mounted
Panels
405 + 21 spares
Weight
1,134 kg panels only
Power
19.4 kW max, 6.5 kW typical, 7 circuits
Data
27 runs on 6 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 27 runs · up to 18 panels per run at 80% · worst 66% · 6× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 115 panels · 66% of port
Run 2Column 215 panels · 66% of port
Run 3Column 315 panels · 66% of port
Run 4Column 415 panels · 66% of port
Run 5Column 515 panels · 66% of port
Run 6Column 615 panels · 66% of port
Run 7Column 715 panels · 66% of port
Run 8Column 815 panels · 66% of port
Run 9Column 915 panels · 66% of port
Run 10Column 1015 panels · 66% of port
Run 11Column 1115 panels · 66% of port
Run 12Column 1215 panels · 66% of port
Run 13Column 1315 panels · 66% of port
Run 14Column 1415 panels · 66% of port
Run 15Column 1515 panels · 66% of port
Run 16Column 1615 panels · 66% of port
Run 17Column 1715 panels · 66% of port
Run 18Column 1815 panels · 66% of port
Run 19Column 1915 panels · 66% of port
Run 20Column 2015 panels · 66% of port
Run 21Column 2115 panels · 66% of port
Run 22Column 2215 panels · 66% of port
Run 23Column 2315 panels · 66% of port
Run 24Column 2415 panels · 66% of port
Run 25Column 2515 panels · 66% of port
Run 26Column 2615 panels · 66% of port
Run 27Column 2715 panels · 66% of port

Power runs 7 circuits · up to 60 panels/circuit · 19.4 kW max · 1× distro

Circuit 1Columns 1 to 4, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L1
Circuit 2Columns 5 to 8, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L2
Circuit 3Columns 9 to 12, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L3
Circuit 4Columns 13 to 16, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L1
Circuit 5Columns 17 to 20, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L2
Circuit 6Columns 21 to 24, snake up and down, hops right60 panels · 2,880 W · 98% · Distro 1 · L3
Circuit 7Columns 25 to 27, snake up and down, hops right45 panels · 2,160 W · 73% · Distro 1 · L1
PatchDistro 1: circuits 1 to 7 (L1×3 L2×2 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,134 kg over 8.10 × 5.06 m, about 28 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 61 panels per 16 A / 230 V circuit (48 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 4 columns need 7 circuits (single columns would need 27, full rows 15).
  5. openPower for a permanent install comes as 7 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 18 panels per run, giving 27 runs, each looped back to a B port on a second unit, worst run 66%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 837 tags · 27 data runs · 7 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

405 pcsLG LSCC018-CZ tiles27×15 wall, 8.1×5.1 m
21 pcsSpare tilesone-off rate 5%
17 pcsSpare receiving cards
17 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,134 kg, about 28 kg/m²

Power 0/2 done

7 pcsHouse circuits (16 A / 230 V)19.4 kW max · ~6.5 kW typical content · from the building's board
438 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

6 pcsNovaStar VX100054/60 ports used (A and B, 3 + 3 units)
54 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
446 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other LG panels

The LSCC series has 8 panels: the LG LSCC series compared.

Where this panel sits

This sheet is listed under LG LED panels, the 1.9 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

This is another size of the LG LSCC018, and the comparisons with other makers’ panels are on that cabinet’s sheet.

How these numbers are derived: power and circuits, panels per data port, the pack list.