This sheet gives the datasheet figures for the LG LSBF015, a 1.56 mm LED panel in a 1200 × 675 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerLG, LSBF series
Pixel pitch1.56 mm
Cabinet size1200 × 675 × 72 mm
Pixels per cabinet768 × 432 (331,776 px)
Weight23 kg (28 kg/m²)
Max power, full white428 W (528 W/m²)
Typical power182 W
Refresh rate3,840 Hz
Brightness600 nits
Viewing angle (H / V)160° / 150°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly2 (our packing assumption)

Source: LG: LSBF015 product specifications, retrieved 2026-09-02. Large-format install cabinet, front service, IP50, 600 nits, 530 W/m² max, 28.4 kg/m². No hang limit published, so the hang figure is a conservative placeholder.

Worked example: a 7 × 7 wall (16:9)

7 columns by 7 rows of this tile makes a 8.40 × 4.72 m wall, the closest this cabinet gets to 16:9, at 5,376 × 3,024 pixels (16.26 MP): 49 panels plus 3 spares at the one-off rate. It weighs about 1,127 kg, carried by the structure it is mounted on.

On European power it draws 21 kW at full white (8.9 kW on typical content), which at an 80% derate is 14 × 16 A / 230 V circuits. Data comes to 49 runs at up to 1 panels per port, worst run 51% loaded, fitting 10 × NovaStar VX1000 with looped A and B data. Every figure is derived by the calculator below. Change the numbers for your own wall.

R151%R251%R351%R451%R551%R651%R751%R851%R951%R1051%R1151%R1251%R1351%R1451%R1551%R1651%R1751%R1851%R1951%R2051%R2151%R2251%R2351%R2451%R2551%R2651%R2751%R2851%R2951%R3051%R3151%R3251%R3351%R3451%R3551%R3651%R3751%R3851%R3951%R4051%R4151%R4251%R4351%R4451%R4551%R4651%R4751%R4851%R4951%wall-mounted: the structure carries 1,127 kg8.40 m (5,376 px)4.72 m (3,024 px)21 kW max · 14× 16 A / 230 V · 49 runs on 10× NovaStar VX1000

Main: 7 × 7 LG LSBF015

Size
8.40 × 4.72 m
Diagonal
379 in
Area
39.7 m²
Resolution
5,376 × 3,024 px
Pixels
16.26 M px
Panels
49 + 3 spares
Weight
1,127 kg panels only
Power
21 kW max, 8.9 kW typical, 14 circuits
Data
49 runs on 10 processors at 60 Hz 8-bit

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit · wall-mounted
MainLG LSBF0157 × 78.40 × 4.72 m · 379 in5,376 × 3,024 pxwall-mounted
Panels
49 + 3 spares
Weight
1,127 kg panels only
Power
21 kW max, 8.9 kW typical, 14 circuits
Data
49 runs on 10 processors at 60 Hz 8-bit

The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 49 runs · up to 1 panels per run at 80% · worst 51% · 10× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 1, rows 1 to 11 panels · 51% of port
Run 2Column 1, rows 2 to 21 panels · 51% of port
Run 3Column 1, rows 3 to 31 panels · 51% of port
Run 4Column 1, rows 4 to 41 panels · 51% of port
Run 5Column 1, rows 5 to 51 panels · 51% of port
Run 6Column 1, rows 6 to 61 panels · 51% of port
Run 7Column 1, rows 7 to 71 panels · 51% of port
Run 8Column 2, rows 1 to 11 panels · 51% of port
Run 9Column 2, rows 2 to 21 panels · 51% of port
Run 10Column 2, rows 3 to 31 panels · 51% of port
Run 11Column 2, rows 4 to 41 panels · 51% of port
Run 12Column 2, rows 5 to 51 panels · 51% of port
Run 13Column 2, rows 6 to 61 panels · 51% of port
Run 14Column 2, rows 7 to 71 panels · 51% of port
Run 15Column 3, rows 1 to 11 panels · 51% of port
Run 16Column 3, rows 2 to 21 panels · 51% of port
Run 17Column 3, rows 3 to 31 panels · 51% of port
Run 18Column 3, rows 4 to 41 panels · 51% of port
Run 19Column 3, rows 5 to 51 panels · 51% of port
Run 20Column 3, rows 6 to 61 panels · 51% of port
Run 21Column 3, rows 7 to 71 panels · 51% of port
Run 22Column 4, rows 1 to 11 panels · 51% of port
Run 23Column 4, rows 2 to 21 panels · 51% of port
Run 24Column 4, rows 3 to 31 panels · 51% of port
Run 25Column 4, rows 4 to 41 panels · 51% of port
Run 26Column 4, rows 5 to 51 panels · 51% of port
Run 27Column 4, rows 6 to 61 panels · 51% of port
Run 28Column 4, rows 7 to 71 panels · 51% of port
Run 29Column 5, rows 1 to 11 panels · 51% of port
Run 30Column 5, rows 2 to 21 panels · 51% of port
Run 31Column 5, rows 3 to 31 panels · 51% of port
Run 32Column 5, rows 4 to 41 panels · 51% of port
Run 33Column 5, rows 5 to 51 panels · 51% of port
Run 34Column 5, rows 6 to 61 panels · 51% of port
Run 35Column 5, rows 7 to 71 panels · 51% of port
Run 36Column 6, rows 1 to 11 panels · 51% of port
Run 37Column 6, rows 2 to 21 panels · 51% of port
Run 38Column 6, rows 3 to 31 panels · 51% of port
Run 39Column 6, rows 4 to 41 panels · 51% of port
Run 40Column 6, rows 5 to 51 panels · 51% of port
Run 41Column 6, rows 6 to 61 panels · 51% of port
Run 42Column 6, rows 7 to 71 panels · 51% of port
Run 43Column 7, rows 1 to 11 panels · 51% of port
Run 44Column 7, rows 2 to 21 panels · 51% of port
Run 45Column 7, rows 3 to 31 panels · 51% of port
Run 46Column 7, rows 4 to 41 panels · 51% of port
Run 47Column 7, rows 5 to 51 panels · 51% of port
Run 48Column 7, rows 6 to 61 panels · 51% of port
Run 49Column 7, rows 7 to 71 panels · 51% of port

Power runs 14 circuits · up to 4 panels/circuit · 21 kW max · 1× distro

Circuit 1Column 1, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L1
Circuit 2Column 1, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L2
Circuit 3Column 2, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L3
Circuit 4Column 2, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L1
Circuit 5Column 3, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L2
Circuit 6Column 3, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L3
Circuit 7Column 4, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L1
Circuit 8Column 4, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L2
Circuit 9Column 5, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L3
Circuit 10Column 5, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L1
Circuit 11Column 6, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L2
Circuit 12Column 6, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L3
Circuit 13Column 7, rows 1 to 44 panels · 1,712 W · 58% · Distro 1 · L1
Circuit 14Column 7, rows 5 to 73 panels · 1,284 W · 44% · Distro 1 · L2
PatchDistro 1: circuits 1 to 14 (L1×5 L2×5 L3×4)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
  2. ✓ confirmedWall-mounted: the wall or structure carries the panels, 1,127 kg over 8.40 × 4.72 m, about 28 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
  3. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 6 panels per 16 A / 230 V circuit (428 W/panel). Typical draw shown separately for the venue/generator ask.
  4. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 14 circuits (full rows would need 14).
  5. openPower for a permanent install comes as 14 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
  6. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  7. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 1 panels per run, giving 49 runs, each looped back to a B port on a second unit, worst run 51%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  8. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  9. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  10. openHome runs cut at run distance + wall height + 5 m service loop.
  11. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  12. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  13. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 147 tags · 49 data runs · 14 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Install list

0/10 done

Panels 0/4 done

49 pcsLG LSBF015 tiles7×7 wall, 8.4×4.7 m
3 pcsSpare tilesone-off rate 5%
2 pcsSpare receiving cards
2 pcsSpare PSUs

Rigging 0/1 done

1 setMounting structuresite-specific, not derived; carries 1,127 kg, about 28 kg/m²

Power 0/2 done

14 pcsHouse circuits (16 A / 230 V)21 kW max · ~8.9 kW typical content · from the building's board
39 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 done

10 pcsNovaStar VX100098/100 ports used (A and B, 5 + 5 units)
98 pcsCat6A home runs, ~40 mrun + height + 5 m loop, A and B
54 pcsCat6 panel jumpersincl. 10% spare
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other LG panels

The LSBF series has 4 panels: the LG LSBF series compared.

Where this panel sits

This sheet is listed under LG LED panels, the 1.5 mm pixel pitch class, fixed-install LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.