RigPlan.app

LEDitgo sB6io · 6.25 mm

This sheet gives the datasheet figures for the LEDitgo sB6io, a 6.25 mm LED panel in a 800 × 900 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerLEDitgo, sB series
Pixel pitch6.25 mm
Cabinet size800 × 900 × 120 mm
Pixels per cabinet128 × 144 (18,432 px)
Weight20.5 kg (28 kg/m²)
Max power, full white590 W (819 W/m²)
Typical power200 W
Refresh rate3,000 Hz
Brightness6,000 nits
Viewing angle (H / V)160° / 80°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly2 (our packing assumption)

Source: LEDitgo: sB6io Technisches Datenblatt, retrieved 2026-09-17. Outdoor rental cabinet, Nationstar 2727 3-in-1 black body, IP65 front, IP54 back. Datasheet gives 590 W maximum and 200 W typical per panel, 6,000 nits, 3,000 Hz minimum and 20.5 kg. Sheet gives 6,000 nits calibrated and 7,500 maximum, a vertical viewing angle of +20° / −60°, refresh above 3,000 Hz. Front and rear service, magnetic fast-rig. Headline pitch 6.2 mm; the sheet’s own geometry (800 mm ÷ 128 px) gives 6.25 mm. No hanging limit is published, so the hang figure is a placeholder.

Worked example: a 10 × 5 wall (16:9)

10 columns by 5 rows of this tile makes a 8.00 × 4.50 m wall, the closest this cabinet gets to 16:9, at 1,280 × 720 pixels (0.92 MP): 50 panels plus 3 spares at the one-off rate. It weighs about 1,150 kg including bumpers, around 460 kg across each of 3 points.

On European power it draws 29.5 kW at full white (10 kW on typical content), which at an 80% derate is 15 × 16 A / 230 V circuits. Data comes to 2 runs at up to 28 panels per port, worst run 71% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R171%R271%2w2w2w2w2w~460 kg~460 kg~460 kg8.00 m (1,280 px)4.50 m (720 px)29.5 kW max · 15× 16 A / 230 V · 2 runs on 1× NovaStar VX1000

Main: 10 × 5 LEDitgo sB6io

Size
8.00 × 4.50 m
Diagonal
361 in
Area
36.0 m²
Resolution
1,280 × 720 px
Pixels
0.92 M px
Panels
50 + 3 spares
Weight
1,150 kg incl. bumpers
Power
29.5 kW max, 10 kW typical, 15 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
6.7 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainLEDitgo sB6io10 × 58.00 × 4.50 m · 361 in1,280 × 720 pxflown
Panels
50 + 3 spares
Weight
1,150 kg incl. bumpers
Power
29.5 kW max, 10 kW typical, 15 circuits
Data
2 runs on 1 processor at 60 Hz 8-bit
Truck
6.7 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Data wiring 2 runs · up to 28 panels per run at 80% · worst 71% · 1× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 525 panels · 71% of port
Run 2Columns 6 to 1025 panels · 71% of port

Power runs 15 circuits · up to 4 panels/circuit · 29.5 kW max · 1× distro

Circuit 1Row 1, columns 1 to 4, left to right (rear)4 panels · 2,360 W · 80% · Distro 1 · L1
Circuit 2Row 1, columns 5 to 7, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L2
Circuit 3Row 1, columns 8 to 10, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L3
Circuit 4Row 2, columns 1 to 4, left to right (rear)4 panels · 2,360 W · 80% · Distro 1 · L1
Circuit 5Row 2, columns 5 to 7, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L2
Circuit 6Row 2, columns 8 to 10, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L3
Circuit 7Row 3, columns 1 to 4, left to right (rear)4 panels · 2,360 W · 80% · Distro 1 · L1
Circuit 8Row 3, columns 5 to 7, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L2
Circuit 9Row 3, columns 8 to 10, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L3
Circuit 10Row 4, columns 1 to 4, left to right (rear)4 panels · 2,360 W · 80% · Distro 1 · L1
Circuit 11Row 4, columns 5 to 7, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L2
Circuit 12Row 4, columns 8 to 10, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L3
Circuit 13Row 5, columns 1 to 4, left to right (rear)4 panels · 2,360 W · 80% · Distro 1 · L1
Circuit 14Row 5, columns 5 to 7, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L2
Circuit 15Row 5, columns 8 to 10, left to right (rear)3 panels · 1,770 W · 60% · Distro 1 · L3
PatchDistro 1: circuits 1 to 15 (L1×5 L2×5 L3×5)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 10 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 4 panels per 16 A / 230 V circuit (590 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Full rows fed left to right need 15 circuits against 20 vertical; rows win here.
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 28 panels per run, giving 2 runs, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 2 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 100 tags · 2 data runs · 15 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Pack list

0/22 packed

Panels 0/4 packed

50 pcsLEDitgo sB6io tiles10×5 wall, 8.0×4.5 m
3 pcsSpare tilesone-off rate 5%
2 pcsSpare receiving cards
2 pcsSpare PSUs

Rigging 0/6 packed

5 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
3 pcsChain hoists, 1 tpoint load ~460 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro29.5 kW max · ~10 kW typical content
15 pcsFeeder lines to wall (16 A / 230 V)~30 m each
39 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

1 pcsNovaStar VX10002/10 ports used
2 pcsCat6A home runs, ~40 mrun + height + 5 m loop
56 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

27 pcsPanel dollies2 tiles per dolly
1 pcsBumper cases8 per case
2 pcsCable trunks~112 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
6.7 mTruck deck, linear32 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other LEDitgo panels

The sB series has 6 panels: the LEDitgo sB series compared.

Where this panel sits

This sheet is listed under LEDitgo LED panels, the 5.9 mm pixel pitch class, rental and touring LED panels, outdoor LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.