This sheet gives the datasheet figures for the Hikvision DS-D4739CF-1AC, a 3.906 mm LED panel in a 500 × 1000 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.
Spec sheet from the manufacturer datasheet
Manufacturer
Hikvision, DS-D47 series
Pixel pitch
3.906 mm
Cabinet size
500 × 1000 × 69 mm
Pixels per cabinet
128 × 256 (32,768 px)
Weight
12.75 kg (26 kg/m²)
Max power, full white
260 W (520 W/m²)
Typical power
87 W
Refresh rate
7,680 Hz
Brightness
4,500 nits
Viewing angle (H / V)
160° / 140°
Max hang
not published by manufacturer
Hanging bar weight
not published by manufacturer
Panels per dolly
6 (our packing assumption)
Source: Hikvision: DS-D4739CF-1AC product specifications, retrieved 2026-09-17. Outdoor rental cabinet with curve lock, SMD Triad LED, rear maintenance, IP65. Page gives 520/174 W/m² maximum and average at 4,500 nits, 7,680 Hz and 12.75 kg per cabinet. No hanging limit is published, so the hang figure is a placeholder.
Worked example: a 16 × 5 wall (16:10)
16 columns by 5 rows of this tile makes a 8.00 × 5.00 m wall, the closest this cabinet gets to 16:10, at 2,048 × 1,280 pixels (2.62 MP): 80 panels plus 4 spares at the one-off rate. It weighs about 1,220 kg including bumpers, around 488 kg across each of 3 points.
On European power it draws 20.8 kW at full white (7 kW on typical content), which at an 80% derate is 8 × 16 A / 230 V circuits. Data comes to 6 runs at up to 15 panels per port, worst run 76% loaded, fitting 1 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.
Main: 16 × 5 Hikvision DS-D4739CF-1AC
Size
8.00 × 5.00 m
Diagonal
371 in
Area
40.0 m²
Resolution
2,048 × 1,280 px
Pixels
2.62 M px
Panels
80 + 4 spares
Weight
1,220 kg incl. bumpers
Power
20.8 kW max, 7 kW typical, 8 circuits
Data
6 runs on 1 processor at 60 Hz 8-bit
Truck
4.4 m of deck
This is a live example. Change the panel and the size in the steps and every figure recomputes.
RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
Main
Hikvision DS-D4739CF-1AC
16 × 5
8.00 × 5.00 m · 371 in
2,048 × 1,280 px
flown
Panels
80 + 4 spares
Weight
1,220 kg incl. bumpers
Power
20.8 kW max, 7 kW typical, 8 circuits
Data
6 runs on 1 processor at 60 Hz 8-bit
Truck
4.4 m of deck
The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 6 runs · up to 15 panels per run at 80% · worst 76% · 1× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
Run 1
Columns 1 to 3
15 panels · 76% of port
Run 2
Columns 4 to 6
15 panels · 76% of port
Run 3
Columns 7 to 9
15 panels · 76% of port
Run 4
Columns 10 to 12
15 panels · 76% of port
Run 5
Columns 13 to 14
10 panels · 50% of port
Run 6
Columns 15 to 16
10 panels · 50% of port
Power runs 8 circuits · up to 10 panels/circuit · 20.8 kW max · 1× distro
Circuit 1
Columns 1 to 2, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L1
Circuit 2
Columns 3 to 4, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L2
Circuit 3
Columns 5 to 6, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L3
Circuit 4
Columns 7 to 8, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L1
Circuit 5
Columns 9 to 10, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L2
Circuit 6
Columns 11 to 12, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L3
Circuit 7
Columns 13 to 14, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L1
Circuit 8
Columns 15 to 16, snake up and down, hops right
10 panels · 2,600 W · 88% · Distro 1 · L2
Patch
Distro 1: circuits 1 to 8 (L1×3 L2×3 L3×2)
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
openSpare panels: 5% of wall count, minimum 2 (one-off).
✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 16 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
✓ confirmedCircuits sized on max load (full white) at 80% derate: 11 panels per 16 A / 230 V circuit (260 W/panel). Typical draw shown separately for the venue/generator ask.
✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 8 circuits (single columns would need 16, full rows 10).
open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 15 panels per run, giving 6 runs, worst run 76%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
openHome runs cut at run distance + wall height + 5 m service loop.
openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
openCases: 6 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 160 tags · 6 data runs · 8 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app