Glux TVsn15 · 1.5625 mm

This sheet gives the datasheet figures for the Glux TVsn15, a 1.5625 mm LED panel in a 250 × 250 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerGlux, TVsn series
Pixel pitch1.5625 mm
Cabinet size250 × 250 × 58 mm
Pixels per cabinet160 × 160 (25,600 px)
Weight2.1 kg (34 kg/m²)
Max power, full white75 W (1200 W/m²)
Typical power36 W
Refresh rate3,600 Hz
Brightness700 nits
Viewing angle (H / V)140° / 140°
Max hangnot published by manufacturer
Hanging bar weightnot published by manufacturer
Panels per dolly14 (our packing assumption)

Source: Glux LED Screen Rental: TVsn series parameters (2016), retrieved 2026-09-11. Table gives 75/36 W per panel; IP40 indoor, carbon fibre, curves to inner and outer arcs. The table rounds the pitch to 1.5 mm; 1.5625 stored is 250 mm over 160 pixels. Figures are from the parameter table on Glux’s rental blog; gluxled.com was unreachable when retrieved. No hanging limit in panels is published (the table rates the lock at 1,000 kg hanging), so the hang figure is a conservative placeholder.

Worked example: a 32 × 18 wall (16:9)

32 columns by 18 rows of this tile makes a 8.00 × 4.50 m wall, the closest this cabinet gets to 16:9, at 5,120 × 2,880 pixels (14.75 MP): 576 panels plus 29 spares at the one-off rate. It weighs about 1,610 kg including bumpers, around 644 kg across each of 3 points.

On European power it draws 43.2 kW at full white (20.7 kW on typical content), which at an 80% derate is 16 × 16 A / 230 V circuits. Data comes to 32 runs at up to 20 panels per port, worst run 71% loaded, fitting 4 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

2w2w2w2w2w2w2w2w2w2w1w1w1w1w1w1wno bar~620 kg~620 kg~620 kg8.00 m (5,120 px)4.50 m (2,880 px)43.2 kW max · 16× 16 A / 230 V · 32 runs on 4× NovaStar VX1000

Main: 32 × 18 Glux TVsn15

Size
8.00 × 4.50 m
Diagonal
361 in
Area
36.0 m²
Resolution
5,120 × 2,880 px
Pixels
14.75 M px
Panels
576 + 29 spares
Weight
1,550 kg incl. bumpers
Power
43.2 kW max, 20.7 kW typical, 16 circuits
Data
32 runs on 4 processors at 60 Hz 8-bit
Truck
15.2 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainGlux TVsn1532 × 188.00 × 4.50 m · 361 in5,120 × 2,880 pxflown
Panels
576 + 29 spares
Weight
1,550 kg incl. bumpers
Power
43.2 kW max, 20.7 kW typical, 16 circuits
Data
32 runs on 4 processors at 60 Hz 8-bit
Truck
15.2 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Bumper stock short: 6 column(s) uncovered; the wall needs more hanging bars than you ownHang depth 18 over the assumed 8-panel max

Data wiring 32 runs · up to 20 panels per run at 80% · worst 71% · 4× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Column 118 panels · 71% of port
Run 2Column 218 panels · 71% of port
Run 3Column 318 panels · 71% of port
Run 4Column 418 panels · 71% of port
Run 5Column 518 panels · 71% of port
Run 6Column 618 panels · 71% of port
Run 7Column 718 panels · 71% of port
Run 8Column 818 panels · 71% of port
Run 9Column 918 panels · 71% of port
Run 10Column 1018 panels · 71% of port
Run 11Column 1118 panels · 71% of port
Run 12Column 1218 panels · 71% of port
Run 13Column 1318 panels · 71% of port
Run 14Column 1418 panels · 71% of port
Run 15Column 1518 panels · 71% of port
Run 16Column 1618 panels · 71% of port
Run 17Column 1718 panels · 71% of port
Run 18Column 1818 panels · 71% of port
Run 19Column 1918 panels · 71% of port
Run 20Column 2018 panels · 71% of port
Run 21Column 2118 panels · 71% of port
Run 22Column 2218 panels · 71% of port
Run 23Column 2318 panels · 71% of port
Run 24Column 2418 panels · 71% of port
Run 25Column 2518 panels · 71% of port
Run 26Column 2618 panels · 71% of port
Run 27Column 2718 panels · 71% of port
Run 28Column 2818 panels · 71% of port
Run 29Column 2918 panels · 71% of port
Run 30Column 3018 panels · 71% of port
Run 31Column 3118 panels · 71% of port
Run 32Column 3218 panels · 71% of port

Power runs 16 circuits · up to 36 panels/circuit · 43.2 kW max · 1× distro

Circuit 1Columns 1 to 2, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
Circuit 2Columns 3 to 4, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L2
Circuit 3Columns 5 to 6, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L3
Circuit 4Columns 7 to 8, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
Circuit 5Columns 9 to 10, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L2
Circuit 6Columns 11 to 12, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L3
Circuit 7Columns 13 to 14, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
Circuit 8Columns 15 to 16, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L2
Circuit 9Columns 17 to 18, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L3
Circuit 10Columns 19 to 20, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
Circuit 11Columns 21 to 22, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L2
Circuit 12Columns 23 to 24, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L3
Circuit 13Columns 25 to 26, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
Circuit 14Columns 27 to 28, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L2
Circuit 15Columns 29 to 30, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L3
Circuit 16Columns 31 to 32, snake up and down, hops right36 panels · 2,700 W · 92% · Distro 1 · L1
PatchDistro 1: circuits 1 to 16 (L1×6 L2×5 L3×5)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 32 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 39 panels per 16 A / 230 V circuit (75 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 2 columns need 16 circuits (single columns would need 32, full rows 18).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 20 panels per run, giving 32 runs, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 14 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 1152 tags · 32 data runs · 16 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Sub-hire1 line to cross-hire

6 colno bumper stock lefthanging bars for 250 mm cabinets
Ready to paste to your cross-hire partner.

Pack list

0/24 packed

Panels 0/4 packed

576 pcsGlux TVsn15 tiles32×18 wall, 8.0×4.5 m
29 pcsSpare tilesone-off rate 5%
24 pcsSpare receiving cards
24 pcsSpare PSUs

Rigging 0/8 packed

10 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
6 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
6 colUNCOVERED: no bumper stock lefthanging bars for 250 mm cabinets
3 pcsChain hoists, 1 tpoint load ~620 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro43.2 kW max · ~20.7 kW typical content
16 pcsFeeder lines to wall (16 A / 230 V)~30 m each
616 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

4 pcsNovaStar VX100032/40 ports used
32 pcsCat6A home runs, ~40 mrun + height + 5 m loop
634 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

44 pcsPanel dollies14 tiles per dolly
2 pcsBumper cases8 per case
22 pcsCable trunks~1298 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
15.2 mTruck deck, linear73 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app