Manufacturer specifications, a worked example wall, and a live calculator preloaded with this tile. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.
| Manufacturer | Absen — Polaris V2 series |
| Pixel pitch | 2.97 mm |
| Cabinet size | 500 × 500 × 78 mm |
| Pixels per cabinet | 168 × 168 (28,224 px) |
| Weight | 8 kg (32 kg/m²) |
| Max power, full white | 153 W (612 W/m²) |
| Typical power | 51 W |
| Max hang | not published by manufacturer |
| Panels per dolly | 8 (our packing assumption) |
Source: Absen — Polaris V2 series cutsheet (NA, 2025-03-18) — retrieved 2026-09-02. Outdoor-rated (IP65/IP54), 3,000 nits. Cutsheet gives 610/204 W/m². Also available as a 500×1000 cabinet at 13 kg. No hanging limit published — conservative placeholder.
16 columns by 9 rows of this tile makes a 8.00 × 4.50 m wall — the closest this cabinet gets to 16:9 — at 2,688 × 1,512 pixels (4.06 MP) — 144 panels plus 8 spares at the one-off rate. It weighs about 1,352 kg including bumpers, around 541 kg across each of 3 points.
On European power it draws 22 kW at full white (7.3 kW on typical content), which at an 80% derate is 8 × 16 A / 230 V circuits. Data comes to 8 runs at up to 18 panels per port, worst run 78% loaded, fitting 1 × Novastar VX1000. Every figure is derived by the calculator below — change the numbers for your own wall.
Job
Walls
Planning several walls on one job — main + IMAG + DJ riser, shared spares and one truck sum — is a Solo feature.
Datasheet PDF parsing — upload a sheet, get the form pre-filled — is a Solo feature. Manufacturers can always parse and submit sheets free on the vendors page.
Quick resolution · size + pitch
Rig stock · bumpers
| 144 pcs | ROE Black Pearl BP2 V2 tiles | 16×9 wall, 8.0×4.5 m | |
| 8 pcs | Spare tiles | one-off rate 5% | |
| 6 pcs | Spare receiving cards | ||
| 6 pcs | Spare PSUs |
| 8 pcs | 2-wide bumpers | from your stock | |
| 3 pcs | Chain hoists, 1 t | point load ~619 kg incl. 1.2 dyn. | |
| 6 pcs | Steels, 1 m | 2 per point | |
| 6 pcs | Spansets | 2 per point | |
| 12 pcs | Shackles, 3.25 t | 4 per point | |
| 9 m | Truss to span wall | +1 m overhang — or house points |
| 1 pcs | 63 A 3-phase distro | 23 kW max · ~11.5 kW typical content | |
| 8 pcs | Feeder lines to wall (16 A / 230 V) | ~30 m each | |
| 150 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
| 2 pcs | Novastar VX1000 | 16/20 ports used | |
| 16 pcs | Cat6A home runs, ~40 m | run + height + 5 m loop | |
| 159 pcs | Cat6 panel jumpers | incl. 10% spare |
| 19 pcs | Panel dollies | 8 tiles per dolly | |
| 1 pcs | Bumper cases | 8 per case | |
| 6 pcs | Cable trunks | ~333 cables total | |
| 1 pcs | Rigging trunks | ||
| 1 set | Gaff, velcro, zip ties, sharpies | always | |
| 6 m | Truck deck, linear | 29 cases est. |
| Run 1 | Column 1 | 9 panels · 43% of port |
| Run 2 | Column 2 | 9 panels · 43% of port |
| Run 3 | Column 3 | 9 panels · 43% of port |
| Run 4 | Column 4 | 9 panels · 43% of port |
| Run 5 | Column 5 | 9 panels · 43% of port |
| Run 6 | Column 6 | 9 panels · 43% of port |
| Run 7 | Column 7 | 9 panels · 43% of port |
| Run 8 | Column 8 | 9 panels · 43% of port |
| Run 9 | Column 9 | 9 panels · 43% of port |
| Run 10 | Column 10 | 9 panels · 43% of port |
| Run 11 | Column 11 | 9 panels · 43% of port |
| Run 12 | Column 12 | 9 panels · 43% of port |
| Run 13 | Column 13 | 9 panels · 43% of port |
| Run 14 | Column 14 | 9 panels · 43% of port |
| Run 15 | Column 15 | 9 panels · 43% of port |
| Run 16 | Column 16 | 9 panels · 43% of port |
| Circuit 1 | Columns 1–2 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 2 | Columns 3–4 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Circuit 3 | Columns 5–6 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L3 |
| Circuit 4 | Columns 7–8 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 5 | Columns 9–10 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Circuit 6 | Columns 11–12 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L3 |
| Circuit 7 | Columns 13–14 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L1 |
| Circuit 8 | Columns 15–16 · snake up/down, hops right | 18 panels · 2,880 W · 98% · Distro 1 · L2 |
| Patch | Distro 1: circuits 1–8 (L1×3 L2×3 L3×2) | |
Every quantity above is derived from the rules below — written with working AV techs and corrected as they red-pen them. Panel and processor specs are placeholders until verified against manufacturer data.
2,688 × 1,512 pixels — 4.06 megapixels across 8.00 × 4.50 metres.
About 22 kW at full white and roughly 7.3 kW on typical content, from a published 153 W maximum per cabinet. Sized on maximum at an 80% derate that is 8 × 16 A / 230 V circuits.
18 at 60 Hz 8-bit with ports loaded to 80%, since each cabinet is 28,224 pixels. That gives 8 runs for this wall; redundant looping would double it.
8 kg per cabinet, or about 32 kg per square metre. The example wall totals roughly 1,352 kg including bumpers, around 541 kg per point across 3 points. Point loads must be verified by a competent rigger.
How these numbers are derived: power and circuits, panels per data port, the pack list.