RigPlan.app

Absen NX2.5 (240×540) · 2.5 mm

This sheet gives the datasheet figures for the Absen NX2.5 (240×540), a 2.5 mm LED panel in a 240 × 540 mm cabinet, with a worked example wall and a calculator preloaded with it. Change columns and rows to get resolution, power draw, circuits, the data wiring plan, rigging quantities and the complete pack list.

Spec sheet from the manufacturer datasheet

ManufacturerAbsen, NX series
Pixel pitch2.5 mm
Cabinet size240 × 540 × 43.5 mm
Pixels per cabinet96 × 216 (20,736 px)
Weight3.1 kg (24 kg/m²)
Max power, full white58 W (448 W/m²)
Typical power19 W
Refresh rate7,680 Hz
Brightness800 nits
Viewing angle (H / V)160° / 160°
Max hang12 panels
Hanging bar weightnot published by manufacturer
Panels per dolly8 (our packing assumption)

Source: Absen: NX series specifications (2026-04-13), retrieved 2026-09-17. Indoor panel for hanging, stacking or fixed mounting by the sheet, front service, IP40 front and IP21 rear, 240 × 270 mm modules. Sheet gives 450/150 W/m² maximum and average (power tolerance ±15% by the sheet) and heat 1,536/512 BTU/h/m²; the rigging limit of 12 is the sheet’s own.

Worked example: a 32 × 8 wall (16:9)

32 columns by 8 rows of this tile makes a 7.68 × 4.32 m wall, the closest this cabinet gets to 16:9, at 3,072 × 1,728 pixels (5.31 MP): 256 panels plus 13 spares at the one-off rate. It weighs about 1,194 kg including bumpers, around 477 kg across each of 3 points.

On European power it draws 14.8 kW at full white (4.9 kW on typical content), which at an 80% derate is 6 × 16 A / 230 V circuits. Data comes to 11 runs at up to 25 panels per port, worst run 77% loaded, fitting 2 × NovaStar VX1000. Every figure is derived by the calculator below. Change the numbers for your own wall.

R177%R277%R377%R477%R577%R677%R777%R877%R977%R1077%R1151%2w2w2w2w2w2w2w2w2w2w1w1w1w1w1w1wno bar~453 kg~453 kg~453 kg7.68 m (3,072 px)4.32 m (1,728 px)14.8 kW max · 6× 16 A / 230 V · 11 runs on 2× NovaStar VX1000

Main: 32 × 8 Absen NX2.5 (240×540)

Size
7.68 × 4.32 m
Diagonal
347 in
Area
33.2 m²
Resolution
3,072 × 1,728 px
Pixels
5.31 M px
Panels
256 + 13 spares
Weight
1,134 kg incl. bumpers
Power
14.8 kW max, 4.9 kW typical, 6 circuits
Data
11 runs on 2 processors at 60 Hz 8-bit
Truck
10.2 m of deck

This is a live example. Change the panel and the size in the steps and every figure recomputes.

RigPlan.appPrinted
Summary
1 wall · 230 V / 16 A circuits · 60 Hz 8-bit
MainAbsen NX2.5 (240×540)32 × 87.68 × 4.32 m · 347 in3,072 × 1,728 pxflown
Panels
256 + 13 spares
Weight
1,134 kg incl. bumpers
Power
14.8 kW max, 4.9 kW typical, 6 circuits
Data
11 runs on 2 processors at 60 Hz 8-bit
Truck
10.2 m of deck

The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing

Bumper stock short: 6 column(s) uncovered; the wall needs more hanging bars than you own

Data wiring 11 runs · up to 25 panels per run at 80% · worst 77% · 2× NovaStar VX1000 · fed from the top

Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.

Run 1Columns 1 to 324 panels · 77% of port
Run 2Columns 4 to 624 panels · 77% of port
Run 3Columns 7 to 924 panels · 77% of port
Run 4Columns 10 to 1224 panels · 77% of port
Run 5Columns 13 to 1524 panels · 77% of port
Run 6Columns 16 to 1824 panels · 77% of port
Run 7Columns 19 to 2124 panels · 77% of port
Run 8Columns 22 to 2424 panels · 77% of port
Run 9Columns 25 to 2724 panels · 77% of port
Run 10Columns 28 to 3024 panels · 77% of port
Run 11Columns 31 to 3216 panels · 51% of port

Power runs 6 circuits · up to 48 panels/circuit · 14.8 kW max · 1× distro

Circuit 1Columns 1 to 6, snake up and down, hops right48 panels · 2,784 W · 95% · Distro 1 · L1
Circuit 2Columns 7 to 12, snake up and down, hops right48 panels · 2,784 W · 95% · Distro 1 · L2
Circuit 3Columns 13 to 17, snake up and down, hops right40 panels · 2,320 W · 79% · Distro 1 · L3
Circuit 4Columns 18 to 22, snake up and down, hops right40 panels · 2,320 W · 79% · Distro 1 · L1
Circuit 5Columns 23 to 27, snake up and down, hops right40 panels · 2,320 W · 79% · Distro 1 · L2
Circuit 6Columns 28 to 32, snake up and down, hops right40 panels · 2,320 W · 79% · Distro 1 · L3
PatchDistro 1: circuits 1 to 6 (L1×2 L2×2 L3×2)

The rules behind every number

Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.

  1. openSpare panels: 5% of wall count, minimum 2 (one-off).
  2. ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 32 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
  3. openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
  4. openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
  5. openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
  6. openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
  7. ✓ confirmedCircuits sized on max load (full white) at 80% derate: 50 panels per 16 A / 230 V circuit (58 W/panel). Typical draw shown separately for the venue/generator ask.
  8. ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical snakes over 6 columns need 6 circuits (single columns would need 32, full rows 8).
  9. open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
  10. ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
  11. ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 25 panels per run, giving 11 runs, worst run 77%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
  12. ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
  13. openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
  14. openHome runs cut at run distance + wall height + 5 m service loop.
  15. openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
  16. ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
  17. openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
  18. openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.

Cable tags 512 tags · 11 data runs · 6 circuits

One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.

Copy tags as CSV 🔒

The tag list, your own label format, and the CSV for a label printer are a Solo feature.

Sub-hire1 line to cross-hire

6 colno bumper stock lefthanging bars for 240 mm cabinets
Ready to paste to your cross-hire partner.

Pack list

0/24 packed

Panels 0/4 packed

256 pcsAbsen NX2.5 tiles32×8 wall, 7.7×4.3 m
13 pcsSpare tilesone-off rate 5%
11 pcsSpare receiving cards
11 pcsSpare PSUs

Rigging 0/8 packed

10 pcs2-wide bumpersfrom your stock · 25 kg each (your standard)
6 pcs1-wide bumpersfrom your stock · 15 kg each (your standard)
6 colUNCOVERED: no bumper stock lefthanging bars for 240 mm cabinets
3 pcsChain hoists, 1 tpoint load ~453 kg incl. 1.2 dyn.
6 pcsSteels, 1 m2 per point
6 pcsSpansets2 per point
12 pcsShackles, 3.25 t4 per point
9 mTruss to span wall+1 m overhang, or house points

Power 0/3 packed

1 pcs63 A 3-phase distro14.8 kW max · ~4.9 kW typical content
6 pcsFeeder lines to wall (16 A / 230 V)~30 m each
275 pcsTRUE1 jumperspanel-to-panel, incl. 10% spare

Data & control 0/3 packed

2 pcsNovaStar VX100011/20 ports used
11 pcsCat6A home runs, ~39 mrun + height + 5 m loop
282 pcsCat6 panel jumpersincl. 10% spare

Cases & truck 0/6 packed

34 pcsPanel dollies8 tiles per dolly
2 pcsBumper cases8 per case
10 pcsCable trunks~574 cables total
1 pcsRigging trunks
1 setGaff, velcro, zip ties, sharpiesalways
10.2 mTruck deck, linear49 cases est.
Planning aid. Rigging figures (points, loads, hardware) must be verified by a competent rigger before anything leaves the ground; panel and processor figures come from the manufacturers' datasheets and can change between revisions. Made with RigPlan, the free LED wall planner · rigplan.app

Other Absen panels

The NX series has 6 panels: the Absen NX series compared.

Where this panel sits

This sheet is listed under Absen LED panels, the 2.5 to 2.6 mm pixel pitch class, fixed-install LED panels, rental and touring LED panels, and the full panel database.

Compare with

How these numbers are derived: power and circuits, panels per data port, the pack list.