Main: 16 × 8 Samsung IF015H
- Size
- 7.68 × 4.32 m
- Area
- 33.2 m²
- Resolution
- 5,120 × 2,880 px
- Pixels
- 14.75 M px
- Panels
- 128 + 7 spares
- Weight
- 742 kg panels only
- Power
- 25.6 kW max, 8.6 kW typical, 16 circuits
- Data
- 32 runs on 8 processors at 60 Hz 8-bit
This is a live example. Change the panel and the size in the steps and every figure recomputes.
| Main | Samsung IF015H | 16 × 8 | 7.68 × 4.32 m | 5,120 × 2,880 px | wall-mounted |
- Panels
- 128 + 7 spares
- Weight
- 742 kg panels only
- Power
- 25.6 kW max, 8.6 kW typical, 16 circuits
- Data
- 32 runs on 8 processors at 60 Hz 8-bit
The install list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 32 runs · up to 4 panels per run at 80% · worst 71% · 8× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
| Run 1 | Column 1, rows 1 to 4 | 4 panels · 71% of port |
| Run 2 | Column 1, rows 5 to 8 | 4 panels · 71% of port |
| Run 3 | Column 2, rows 1 to 4 | 4 panels · 71% of port |
| Run 4 | Column 2, rows 5 to 8 | 4 panels · 71% of port |
| Run 5 | Column 3, rows 1 to 4 | 4 panels · 71% of port |
| Run 6 | Column 3, rows 5 to 8 | 4 panels · 71% of port |
| Run 7 | Column 4, rows 1 to 4 | 4 panels · 71% of port |
| Run 8 | Column 4, rows 5 to 8 | 4 panels · 71% of port |
| Run 9 | Column 5, rows 1 to 4 | 4 panels · 71% of port |
| Run 10 | Column 5, rows 5 to 8 | 4 panels · 71% of port |
| Run 11 | Column 6, rows 1 to 4 | 4 panels · 71% of port |
| Run 12 | Column 6, rows 5 to 8 | 4 panels · 71% of port |
| Run 13 | Column 7, rows 1 to 4 | 4 panels · 71% of port |
| Run 14 | Column 7, rows 5 to 8 | 4 panels · 71% of port |
| Run 15 | Column 8, rows 1 to 4 | 4 panels · 71% of port |
| Run 16 | Column 8, rows 5 to 8 | 4 panels · 71% of port |
| Run 17 | Column 9, rows 1 to 4 | 4 panels · 71% of port |
| Run 18 | Column 9, rows 5 to 8 | 4 panels · 71% of port |
| Run 19 | Column 10, rows 1 to 4 | 4 panels · 71% of port |
| Run 20 | Column 10, rows 5 to 8 | 4 panels · 71% of port |
| Run 21 | Column 11, rows 1 to 4 | 4 panels · 71% of port |
| Run 22 | Column 11, rows 5 to 8 | 4 panels · 71% of port |
| Run 23 | Column 12, rows 1 to 4 | 4 panels · 71% of port |
| Run 24 | Column 12, rows 5 to 8 | 4 panels · 71% of port |
| Run 25 | Column 13, rows 1 to 4 | 4 panels · 71% of port |
| Run 26 | Column 13, rows 5 to 8 | 4 panels · 71% of port |
| Run 27 | Column 14, rows 1 to 4 | 4 panels · 71% of port |
| Run 28 | Column 14, rows 5 to 8 | 4 panels · 71% of port |
| Run 29 | Column 15, rows 1 to 4 | 4 panels · 71% of port |
| Run 30 | Column 15, rows 5 to 8 | 4 panels · 71% of port |
| Run 31 | Column 16, rows 1 to 4 | 4 panels · 71% of port |
| Run 32 | Column 16, rows 5 to 8 | 4 panels · 71% of port |
Power runs 16 circuits · up to 8 panels/circuit · 25.6 kW max · 1× distro
| Circuit 1 | Column 1 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Circuit 2 | Column 2 | 8 panels · 1,600 W · 54% · Distro 1 · L2 |
| Circuit 3 | Column 3 | 8 panels · 1,600 W · 54% · Distro 1 · L3 |
| Circuit 4 | Column 4 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Circuit 5 | Column 5 | 8 panels · 1,600 W · 54% · Distro 1 · L2 |
| Circuit 6 | Column 6 | 8 panels · 1,600 W · 54% · Distro 1 · L3 |
| Circuit 7 | Column 7 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Circuit 8 | Column 8 | 8 panels · 1,600 W · 54% · Distro 1 · L2 |
| Circuit 9 | Column 9 | 8 panels · 1,600 W · 54% · Distro 1 · L3 |
| Circuit 10 | Column 10 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Circuit 11 | Column 11 | 8 panels · 1,600 W · 54% · Distro 1 · L2 |
| Circuit 12 | Column 12 | 8 panels · 1,600 W · 54% · Distro 1 · L3 |
| Circuit 13 | Column 13 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Circuit 14 | Column 14 | 8 panels · 1,600 W · 54% · Distro 1 · L2 |
| Circuit 15 | Column 15 | 8 panels · 1,600 W · 54% · Distro 1 · L3 |
| Circuit 16 | Column 16 | 8 panels · 1,600 W · 54% · Distro 1 · L1 |
| Patch | Distro 1: circuits 1 to 16 (L1×6 L2×5 L3×5) | |
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
- openSpare panels: 5% of wall count, minimum 2 (wall-mounted, spares kept on site at the one-off rate).
- ✓ confirmedWall-mounted: the wall or structure carries the panels, 742 kg over 7.68 × 4.32 m, about 22 kg/m² plus your fixing hardware. Nothing hangs from the panels, so the hang limit does not apply. The structure is designed for the site and is not derived here; no bumpers, points, ground support, distros, cases or truck are listed.
- ✓ confirmedCircuits sized on max load (full white) at 80% derate: 14 panels per 16 A / 230 V circuit (200 W/panel). Typical draw shown separately for the venue/generator ask.
- ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 16 circuits (full rows would need 16).
- openPower for a permanent install comes as 16 house circuits from the building's distribution board; no distro or feeders are listed. TRUE1 jumpers = panels − runs, +10% spare.
- ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
- ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 4 panels per run, giving 32 runs, each looped back to a B port on a second unit, worst run 71%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
- ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
- openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
- openHome runs cut at run distance + wall height + 5 m service loop.
- openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
- ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
- openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 288 tags · 32 data runs · 16 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Copy tags as CSV 🔒The tag list, your own label format, and the CSV for a label printer are a Solo feature.
Panels 0/4 done
| 128 pcs | Samsung IF015H tiles | 16×8 wall, 7.7×4.3 m | ||
| 7 pcs | Spare tiles | one-off rate 5% | ||
| 6 pcs | Spare receiving cards | |||
| 6 pcs | Spare PSUs |
Rigging 0/1 done
| 1 set | Mounting structure | site-specific, not derived; carries 742 kg, about 22 kg/m² |
Power 0/2 done
| 16 pcs | House circuits (16 A / 230 V) | 25.6 kW max · ~8.6 kW typical content · from the building's board | ||
| 124 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
Data & control 0/3 done
| 8 pcs | NovaStar VX1000 | 64/80 ports used (A and B, 4 + 4 units) | ||
| 64 pcs | Cat6A home runs, ~39 m | run + height + 5 m loop, A and B | ||
| 141 pcs | Cat6 panel jumpers | incl. 10% spare |