Main: 16 × 9 Absen PL3.9 Pro V2
- Size
- 8.00 × 4.50 m
- Area
- 36.0 m²
- Resolution
- 2,048 × 1,152 px
- Pixels
- 2.36 M px
- Panels
- 144 + 8 spares
- Weight
- 1,352 kg incl. bumpers
- Power
- 28.8 kW max, 9.6 kW typical, 16 circuits
- Data
- 6 runs on 1 processor at 60 Hz 8-bit
- Truck
- 5.8 m of deck
This is a live example. Change the panel and the size in the steps and every figure recomputes.
| Main | Absen PL3.9 Pro V2 | 16 × 9 | 8.00 × 4.50 m | 2,048 × 1,152 px | flown |
- Panels
- 144 + 8 spares
- Weight
- 1,352 kg incl. bumpers
- Power
- 28.8 kW max, 9.6 kW typical, 16 circuits
- Data
- 6 runs on 1 processor at 60 Hz 8-bit
- Truck
- 5.8 m of deck
The pack list, the data wiring and power run plans, the cable tags and the system sheet print with a Solo account: rigplan.app/pricing
Data wiring 6 runs · up to 31 panels per run at 80% · worst 68% · 1× NovaStar VX1000 · fed from the top
Display connection file 🔒 The file NovaLCT loads under Screen Connection, Load from File; the receiving card file still comes from the maker.
| Run 1 | Columns 1 to 3 | 27 panels · 68% of port |
| Run 2 | Columns 4 to 6 | 27 panels · 68% of port |
| Run 3 | Columns 7 to 9 | 27 panels · 68% of port |
| Run 4 | Columns 10 to 12 | 27 panels · 68% of port |
| Run 5 | Columns 13 to 14 | 18 panels · 45% of port |
| Run 6 | Columns 15 to 16 | 18 panels · 45% of port |
Power runs 16 circuits · up to 9 panels/circuit · 28.8 kW max · 1× distro
| Circuit 1 | Column 1 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Circuit 2 | Column 2 | 9 panels · 1,800 W · 61% · Distro 1 · L2 |
| Circuit 3 | Column 3 | 9 panels · 1,800 W · 61% · Distro 1 · L3 |
| Circuit 4 | Column 4 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Circuit 5 | Column 5 | 9 panels · 1,800 W · 61% · Distro 1 · L2 |
| Circuit 6 | Column 6 | 9 panels · 1,800 W · 61% · Distro 1 · L3 |
| Circuit 7 | Column 7 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Circuit 8 | Column 8 | 9 panels · 1,800 W · 61% · Distro 1 · L2 |
| Circuit 9 | Column 9 | 9 panels · 1,800 W · 61% · Distro 1 · L3 |
| Circuit 10 | Column 10 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Circuit 11 | Column 11 | 9 panels · 1,800 W · 61% · Distro 1 · L2 |
| Circuit 12 | Column 12 | 9 panels · 1,800 W · 61% · Distro 1 · L3 |
| Circuit 13 | Column 13 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Circuit 14 | Column 14 | 9 panels · 1,800 W · 61% · Distro 1 · L2 |
| Circuit 15 | Column 15 | 9 panels · 1,800 W · 61% · Distro 1 · L3 |
| Circuit 16 | Column 16 | 9 panels · 1,800 W · 61% · Distro 1 · L1 |
| Patch | Distro 1: circuits 1 to 16 (L1×6 L2×5 L3×5) | |
The rules behind every number
Every quantity above is derived from the rules below, written with working AV techs and corrected as they red-pen them.
- openSpare panels: 5% of wall count, minimum 2 (one-off).
- ✓ confirmedBumpers come from your stock, not a formula: widest first, combined to cover 16 columns. Partial coverage (a wider bar over fewer columns) is allowed and noted; shortfalls are flagged instead of invented.
- openHanging bar weights for this system are not published, so your standard 35/25/15 kg for 3/2/1-wide applies.
- openRigging points: one per ≤3 m of wall width, minimum 2, giving 3. 1× 1 t hoist per point.
- openPer point: 2× steel, 2× spanset, 4× 3.25 t shackle.
- openPoint load: wall weight ÷ points × 1.2 dynamic factor. Warn above 800 kg per 1 t hoist.
- ✓ confirmedCircuits sized on max load (full white) at 80% derate: 14 panels per 16 A / 230 V circuit (200 W/panel). Typical draw shown separately for the venue/generator ask.
- ✓ confirmedPower runs follow the connectors: in one side, out the other, gendered plugs, jumpers as short as the maker can get away with. Vertical works both ways, sideways only one hop to the right (rear view), so a run may snake up and down across adjacent columns, but never left and right. Vertical strings per column → 16 circuits (full rows would need 18).
- open1× 63 A 3-phase distro per 18 circuits (1). TRUE1 jumpers = panels − runs, +10% spare.
- ✓ confirmedRuns are load-balanced: panels split evenly across the circuits a shape needs (12+12, never 18+6) so every main-in pulls about the same. Phases are a suggested round-robin L1 to L3 within each distro.
- ✓ confirmedExact-pixel mapping (NovaStar VX1000): a port carries only the panels wired to it, and data snakes in any direction (unlike power). Wiring follows whole columns as vertical serpentines, numbered from the left seen from the rear, the natural reading order when patching, with every run capped at 80% of 650 k px per 1G port at 60 Hz 8-bit (threshold, refresh and depth adjustable): at most 31 panels per run, giving 6 runs, worst run 68%. Loads balance evenly across runs. Capacity is the sheet figure at 8-bit; refresh scales as 60/Hz. No sheet publishes a per-port width cap; the MX40 Pro’s minimum load width is applied where it bites. Correct me with measured figures.
- ✓ confirmedRedundancy defaults off. Rental shows rarely run looped data; it is primarily a critical-installation feature. Turning it on gives every run a B loop from a second unit, so the processor count doubles.
- openData enters each run at the top of its first column and snakes on from there, so the drawing, the cable tags and the connection file all start at that end. The entry end is a choice per wall; the runs, ports and processors stay the same either way.
- openHome runs cut at run distance + wall height + 5 m service loop.
- openProcessors are checked on two limits: port count and total pixel capacity (capacities placeholder).
- ✓ confirmedProcessor list defaults to NovaStar (VX1000 first, UHD Jr / MCTRL / MX / VX family). Rental houses rarely run Brompton; it stays available for the shops that do. All figures verified against manufacturer spec sheets.
- openCases: 8 panels per dolly, 60 cables per trunk, 8 bumpers per case, rigging trunk per 6 points. Truck estimate: 0.5 m² footprint per case over 2.4 m trailer width.
- openElectronics spares: 1 receiving card per 25 panels, 1 PSU per 25, minimum 1 each.
Cable tags 288 tags · 6 data runs · 16 circuits
One label per cable, both ends named, in the order the runs are wired: cabinets as column and row seen from the rear, c1r1 top left. Print them, or copy the list as CSV for a label printer.
Copy tags as CSV 🔒The tag list, your own label format, and the CSV for a label printer are a Solo feature.
Panels 0/4 packed
| 144 pcs | Absen PL3.9 Pro V2 tiles | 16×9 wall, 8.0×4.5 m | ||
| 8 pcs | Spare tiles | one-off rate 5% | ||
| 6 pcs | Spare receiving cards | |||
| 6 pcs | Spare PSUs |
Rigging 0/6 packed
| 8 pcs | 2-wide bumpers | from your stock · 25 kg each (your standard) | ||
| 3 pcs | Chain hoists, 1 t | point load ~541 kg incl. 1.2 dyn. | ||
| 6 pcs | Steels, 1 m | 2 per point | ||
| 6 pcs | Spansets | 2 per point | ||
| 12 pcs | Shackles, 3.25 t | 4 per point | ||
| 9 m | Truss to span wall | +1 m overhang, or house points |
Power 0/3 packed
| 1 pcs | 63 A 3-phase distro | 28.8 kW max · ~9.6 kW typical content | ||
| 16 pcs | Feeder lines to wall (16 A / 230 V) | ~30 m each | ||
| 141 pcs | TRUE1 jumpers | panel-to-panel, incl. 10% spare |
Data & control 0/3 packed
| 1 pcs | NovaStar VX1000 | 6/10 ports used | ||
| 6 pcs | Cat6A home runs, ~40 m | run + height + 5 m loop | ||
| 159 pcs | Cat6 panel jumpers | incl. 10% spare |
Cases & truck 0/6 packed
| 19 pcs | Panel dollies | 8 tiles per dolly | ||
| 1 pcs | Bumper cases | 8 per case | ||
| 6 pcs | Cable trunks | ~322 cables total | ||
| 1 pcs | Rigging trunks | |||
| 1 set | Gaff, velcro, zip ties, sharpies | always | ||
| 5.8 m | Truck deck, linear | 28 cases est. |